Quantification of intramyocardial blood volume with 99mTc-RBC SPECT-CT imaging: A preclinical study

被引:12
|
作者
Mohy-ud-Din, Hassan [1 ,3 ]
Boutagy, Nabil E. [2 ]
Stendahl, John C. [2 ]
Zhuang, Zhen W. [2 ]
Sinusas, Albert J. [1 ,2 ]
Liu, Chi [1 ]
机构
[1] Yale Univ, Dept Radiol & Biomed Imaging, New Haven, CT 06520 USA
[2] Yale Univ, Sch Med, Dept Med, Sect Cardiovasc Med, New Haven, CT 06510 USA
[3] Shaukat Khanum Mem Canc Hosp & Res Ctr, 7-A,Block R-3, Lahore 54000, Pakistan
关键词
Intramyocardial blood volume; partial volume correction; SPECT-CT imaging; microCT; coronary microcirculation; cardio-respiratory motion correction; CORONARY MICROVASCULAR DYSFUNCTION; MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY; CLINICAL PRESENTATION; PERFUSION PET; FLOW; PATHOPHYSIOLOGY; PREVALENCE; VALIDATION; PRESSURE; MARKER;
D O I
10.1007/s12350-017-0970-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundCurrently, there is no established non-invasive imaging approach to directly evaluate myocardial microcirculatory function in order to diagnose microvascular disease independent of co-existing epicardial disease. In this work, we developed a methodological framework for quantification of intramyocardial blood volume (IMBV) as a novel index of microcirculatory function with SPECT/CT imaging of Tc-99m-labeled red blood cells (RBCs).MethodsDual-gated myocardial SPECT/CT equilibrium imaging of Tc-99m-RBCs was performed on twelve canines under resting conditions. Five correction schemes were studied: cardiac gating with no other corrections (CG), CG with attenuation correction (CG+AC), CG+AC with scatter correction (CG+AC+SC), dual cardiorespiratory gating with AC+SC (DG+AC+SC), and DG+AC+SC with partial volume correction (DG+AC+SC+PVC). Quantification of IMBV using each approach was evaluated in comparison to those obtained from all corrections. The in vivo SPECT estimates of IMBV values were validated against those obtained from ex vivo microCT imaging of the casted hearts.ResultsThe estimated IMBV with all corrections was 0.150.03 for the end-diastolic phase and 0.11 +/- 0.03 for the end-systolic phase. The cycle-dependent change in IMBV (IMBV) with all corrections was 23.9 +/- 8.6%. Schemes that applied no correction or partial correction resulted in significant over-estimation of IMBV and significant under-underestimation of IMBV. Estimates of IMBV and IMBV using all corrections were consistent with values reported in the literature using invasive techniques. In vivo SPECT estimates of IMBV strongly correlated (R(2)0.70) with ex vivo measures for the various correction schemes, while the fully corrected scheme yielded the smallest bias.Conclusions Non-invasive quantification of IMBV is feasible using Tc-99m-RBCs SPECT/CT imaging, however, requires full compensation of physical degradation factors.
引用
收藏
页码:2096 / 2111
页数:16
相关论文
共 50 条
  • [41] Clinical application of SPECT-CT with 99mTc-Tektrotyd in patients with neuroendocrine tumors (NETs)
    Sergieva, S.
    Robev, B.
    Mihaylova, Z.
    Facirova, A.
    Dimcheva, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S492 - S492
  • [42] Ectopic Thoracic Kidney Evaluation Using 99mTc Dimercaptosuccinic Acid SPECT-CT
    Singh, Harmandeep
    Sharma, Punit
    Nazar, Aftab Hasan
    Das, Kalpajyoti
    Naswa, Niraj
    Singla, Suhas
    Kumar, Rakesh
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (07) : E170 - E172
  • [43] Role of 99mTc-Tektrotyd SPECT-CT in patients with pulmonary neuroendocrine tumors (NETs)
    Sergieva, Sonya
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [44] The role of 99mTc-MIBI SPECT-CT in reoperation therapy of persistent hyperparathyroidism patients
    Yin, Lijie
    Guo, Dandan
    Liu, Jie
    Yan, Jue
    OPEN MEDICINE, 2015, 10 (01): : 462 - 467
  • [45] Optimization of SPECT/CT imaging protocols for quantitative and qualitative 99mTc SPECT
    Dennis Kupitz
    Heiko Wissel
    Jan Wuestemann
    Stephanie Bluemel
    Maciej Pech
    Holger Amthauer
    Michael C. Kreissl
    Oliver S. Grosser
    EJNMMI Physics, 8
  • [46] Quantification of 99mTc-DPD concentration in the lumbar spine with SPECT/CT
    Michal Cachovan
    Alexander Hans Vija
    Joachim Hornegger
    Torsten Kuwert
    EJNMMI Research, 3
  • [47] Quantification of 99mTc-DPD concentration in the lumbar spine with SPECT/CT
    Cachovan, Michal
    Vija, Alexander Hans
    Hornegger, Joachim
    Kuwert, Torsten
    EJNMMI RESEARCH, 2013, 3 : 1 - 8
  • [48] Optimization of SPECT/CT imaging protocols for quantitative and qualitative 99mTc SPECT
    Kupitz, Dennis
    Wissel, Heiko
    Wuestemann, Jan
    Bluemel, Stephanie
    Pech, Maciej
    Amthauer, Holger
    Kreissl, Michael C.
    Grosser, Oliver S.
    EJNMMI PHYSICS, 2021, 8 (01)
  • [49] Cerebral Infarction on 99mTc-MDP SPECT/CT Imaging
    Guo, Jia
    Hu, Shuang
    Wang, Haitao
    Kuang, Anren
    CLINICAL NUCLEAR MEDICINE, 2013, 38 (11) : 925 - 927
  • [50] Clinical Application of SPECT-CT Imaging with 99mTc/PSMA T4 in patients with Recurrent Prostate Cancer
    Sergieva, Sonya
    Robev, Bozhil
    Dimcheva, Milena
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61