Method of spatiotemporally monitoring acoustic cavitation based on radio frequency signal entropy analysis

被引:1
|
作者
Song Ren-Jie [1 ,2 ]
Yuan Zi-Yan [1 ]
Qi, Zhang [1 ]
Jie, Yu [1 ,3 ]
Xue Hong-Hui [1 ]
Juan, Tu [1 ,4 ]
Dong, Zhang [1 ,4 ]
机构
[1] Nanjing Univ, Sch Phys, Key Lab Modern Acoust, Minist Educ, Nanjing 210093, Peoples R China
[2] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Suzhou 215163, Peoples R China
[3] Nanjing Univ Chinese Med, Affiliated Hosp, Nanjing 210029, Peoples R China
[4] Chinese Acad Sci, Inst Acoust, State Key Lab Acoust, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
acoustic cavitation; high intensity focused ultrasound; ultrasound radio frequency signal; information entropy; INTENSITY FOCUSED ULTRASOUND;
D O I
10.7498/aps.71.20220558
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The violent inertial cavitation effect generated during high intensity focused ultrasound (HIFU) treatment may damage healthy tissues around the target area. Therefore, it is urgent to develop new technical approaches that can quantitatively monitor the acoustic cavitation motions in biological tissues with high precision in space and time, so as to ensure clinical safety and effectiveness. Compared with the traditional commercial ultrasonic gray value signal, the ultrasonic radio frequency (RF) signal can well retain more detailed information about the acoustic scattering signal. As a statistical parameter not based on mathematical function model, the information entropy can characterize the spatiotemporal evolution state of disorder of scatters inside tissues resulting from acoustic cavitation. Therefore, this paper proposes a real-time monitoring system for spatiotemporal evolution of acoustic cavitation based on the entropy analysis of ultrasonic RF signals. First, the original RF signal of scattered echoes generated by HIFU-induced cavitation bubbles inside the gel phantom is obtained by using a modified B-ultrasound system, and the two-dimensional mean filtering method is used to suppress the HIFU-induced strong interferences overlapping with cavitation monitoring imaging signals. Then, the dynamic variation range of the RF signal is expanded through data standardization processing, and the entropy image is reconstructed based on the sliding window information entropy analysis to demonstrate the spatiotemporal evolution status of the HIFU-induced cavitation behanviors. The experimental results indicate that the acoustic cavitation imaging algorithm based on RF signal entropy analysis should be more sensitive and accurate than the B-model gray scale imaging method for determining the onset time and spatial position of cavitation activities, which is helpful in ensuring the safety and efficacy of HIFU clinical treatment. Thepresent work will provide a useful tool for the spatiotemporal monitoring of the acoustic cavitation generated in tissues during HIFU treatment, and lays a solid theoretical and experimental foundation to establish an effective quantity-effect evaluation system for the cavitation related biological effect.
引用
收藏
页数:10
相关论文
共 36 条
  • [1] FOR WHOM THE BUBBLE GROWS: PHYSICAL PRINCIPLES OF BUBBLE NUCLEATION AND DYNAMICS IN HISTOTRIPSY ULTRASOUND THERAPY
    Bader, Kenneth B.
    Vlaisavljevich, Eli
    Maxwell, Adam D.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (05): : 1056 - 1080
  • [2] Physical mechanisms of the therapeutic effect of ultrasound - (A review)
    Bailey, MR
    Khokhlova, VA
    Sapozhnikov, OA
    Kargl, SG
    Crum, LA
    [J]. ACOUSTICAL PHYSICS, 2003, 49 (04) : 369 - 388
  • [3] [陈楚怡 Chen Chuyi], 2015, [声学学报, Acta Acustica], V40, P563
  • [4] Impact of cavitation on lesion formation induced by high intensity focused ultrasound
    Fan, Pengfei
    Yu, Jie
    Yang, Xin
    Tu, Juan
    Guo, Xiasheng
    Huang, Pintong
    Zhang, Dong
    [J]. CHINESE PHYSICS B, 2017, 26 (05)
  • [5] The Relationship of Cavitation to the Negative Acoustic Pressure Amplitude in Ultrasonic Therapy
    Fan, Ting-Bo
    Tu, Juan
    Luo, Lin-Jiao
    Guo, Xia-Sheng
    Huang, Pin-Tong
    Zhang, Dong
    [J]. CHINESE PHYSICS LETTERS, 2016, 33 (08)
  • [6] Tissue lesion induced by a spherical cavity transducer
    Geng Hao
    Fan Ting-Bo
    Zhang Zhe
    Tu Juan
    Guo Xia-Sheng
    Li Fa-Qi
    Zhang Dong
    [J]. ACTA PHYSICA SINICA, 2014, 63 (04)
  • [7] Sensitive ultrasonic detection of dystrophic skeletal muscle in patients with duchenne muscular dystrophy using an entropy-based signal receiver
    Hughes, Michael S.
    Marsh, Jon N.
    Wallace, Kirk D.
    Donahue, Tamara A.
    Connolly, Anne M.
    Lanza, Gregory M.
    Wickline, Samuel A.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (08): : 1236 - 1243
  • [8] Magnetic resonance-guided, high-intensity focused ultrasound sonolysis: potential applications for stroke
    Ilyas, Adeel
    Chen, Ching-Jen
    Ding, Dale
    Romeo, Andrew
    Buell, Thomas J.
    Wang, Tony R.
    Kalani, M. Yashar S.
    Park, Min S.
    [J]. NEUROSURGICAL FOCUS, 2018, 44 (02)
  • [9] An Introduction to High Intensity Focused Ultrasound: Systematic Review on Principles, Devices, and Clinical Applications
    Izadifar, Zahra
    Izadifar, Zohreh
    Chapman, Dean
    Babyn, Paul
    [J]. JOURNAL OF CLINICAL MEDICINE, 2020, 9 (02)
  • [10] Real-time monitoring of high intensity focused ultrasound focal damage based on transducer driving signal
    Jun, Qian
    Xie Wei
    Zhou Xiao-Wei
    Tan Jian-Wen
    Wang Zhi-Biao
    Du Yong-Hong
    Li Yan-Hao
    [J]. ACTA PHYSICA SINICA, 2022, 71 (03)