Aero-elastic testing of multi-spanned transmission line subjected to downbursts

被引:70
|
作者
Elawady, Amal [1 ]
Aboshosha, Haitham [2 ]
El Damatty, Ashraf [3 ,4 ]
Bitsuamlak, Girma [3 ,4 ]
Hangan, Horia [3 ,4 ]
Elatar, Ahmed [4 ,5 ]
机构
[1] Florida Int Univ, Dept Civil & Environm Engn, Miami, FL 33199 USA
[2] Western Univ, Boundary Layer Wind Tunnel Lab, London, ON, Canada
[3] Western Univ, Dept Civil & Environm Engn, London, ON, Canada
[4] Western Univ, Wind Engn Energy & Environm WindEEE, London, ON, Canada
[5] Oak Ridge Natl Lab, Oak Ridge, TN USA
基金
加拿大自然科学与工程研究理事会;
关键词
Aero-elastic modeling; Downburst; Microburst; Transmission line; Cable; Wind load; High-intensity wind; WindEEE; Resonance; IMPINGING JETS; BEHAVIOR; CONDUCTORS; BOUNDARY; OUTFLOWS; WINDS;
D O I
10.1016/j.jweia.2017.07.010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper reports the first aero-elastic test conducted under a scaled downburst wind field at the WindEEE dome facility at the University of Western Ontario, Canada. The main purpose of the test is to assess the dynamic response of a multi-span transmission line. The study starts by providing a characterization of the downburst wind field produced in WindEEE including a comparison with results of previously conducted numerical simulations. A number of test configurations, involving different locations of the downburst relative to the line, is considered. A decomposition approach is developed to separate between the resonant and the background components of the response. The results are presented in the form of a dynamic magnification factor that relates the peak response including the dynamic effect to the maximum quasi-static response. The test results show that the resonance contribution ranges between 5% and 10% of the peak response for the tower. They also show that the dynamic response of the conductors can reach up to 30% and 12% of the peak response,at low and high downburst speeds, respectively.
引用
收藏
页码:194 / 216
页数:23
相关论文
共 9 条
  • [1] Aero-elastic response of transmission line system subjected to downburst wind: Validation of numerical model using experimental data
    Elawady, Amal
    Aboshosha, Haitham
    El Damatty, Ashraf
    WIND AND STRUCTURES, 2018, 27 (02) : 71 - 88
  • [2] Study of wind tunnel tests of a full aero-elastic model of electrical transmission tower-line systems
    Liang, Shuguo
    Zou, Lianghao
    Han, Yinquan
    Zhao, Lin
    Xie, Qiang
    Ge, Yaojun
    Li, Jie
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2010, 43 (05): : 70 - 78
  • [3] Analysis of aero-dynamic damping of transmission tower based on aero-elastic model wind tunnel
    Zou, Lianghao
    Liang, Shuguo
    Wang, Shuliang
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2015, 35 (02): : 268 - 275
  • [4] Wind-induced vibration of UHV transmission tower line system: Wind tunnel test on aero-elastic model
    Xie, Qiang
    Cai, Yunzhu
    Xue, Songtao
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2017, 171 : 219 - 229
  • [5] Critical load cases for lattice transmission line structures subjected to downbursts: Economic implications for design of transmission lines
    El Damatty, Ashraf
    Elawady, Amal
    ENGINEERING STRUCTURES, 2018, 159 : 213 - 226
  • [6] Wind loading identification of transmission towers based-on wind tunnel tests of full aero-elastic model
    Xiong, Tiehua
    Liang, Shuguo
    Zou, Lianghao
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2010, 31 (10): : 48 - 54
  • [7] Aero-elastic analysis and classical flutter of a multi-megawatt slender bladed horizontal-axis wind turbine
    Sayed, M. A.
    Lutz, T.
    Kraemer, E.
    Borisade, F.
    PROGRESS IN RENEWABLE ENERGIES OFFSHORE, 2016, : 617 - 625
  • [8] Multi-hazard assessment of transmission line systems subjected to independent non-concurrent turbulent winds and ground accelerations
    Miguel, Leandro F. Fadel
    Alminhana, Fabio
    Brito, Jherbyson Williams Silva
    Sousa, David Madeira
    Beck, Andre T.
    STRUCTURAL SAFETY, 2023, 105
  • [9] Global reliability assessment of coupled transmission tower-insulator-line systems considering soil-structure interaction subjected to multi-hazard of wind and ice
    Wang, Tao
    Dong, You
    Wang, Lei
    Lu, Dagang
    Hu, Shuling
    Tan, Yiqiu
    Li, Zhengliang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 223