INNOVATORY PRODUCTION OF RADIOISOTOPES 117mSn, 186Re AND 188Re FOR LABORATORY TESTS AND THE FUTURE APPLICATION IN NUCLEAR MEDICINE

被引:2
|
作者
Mlynczyk, Natalia [1 ]
Konefal, Adam [1 ]
Orlef, Andrzej [2 ,3 ]
Sokol, Maria [2 ,3 ]
Rostocka, Justyna [1 ]
Lniak, Wioletta [1 ]
Gawelczyk, Bartlomiej [1 ]
机构
[1] Univ Silesia Katowice, Inst Phys, Katowice, Poland
[2] Maria Sklodowska Curie Mem Canc Ctr, Dept Med Phys, Gliwice, Poland
[3] Inst Oncol, Gliwice, Poland
来源
ACTA PHYSICA POLONICA B | 2020年 / 51卷 / 03期
关键词
INDUCED RADIOACTIVITY; LINEAR ACCELERATORS; NEUTRON RADIATION; CROSS-SECTIONS; ROOM;
D O I
10.5506/APhysPolB.51.867
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In this work, innovatory production of three radioisotopes Sn-117m, Re-186 and Re-188, which can be used in nuclear medicine, is described. The natural tin and rhenium targets were irradiated by a high-energy 20 MV X-ray therapeutic beam from a medical linear accelerator. Additionally, the targets were in the photoneutron field. The radioisotopes were obtained in photonuclear and neutron reactions. A special lead-PMMA system was used to increase the slowed-down neutron flux in the target volume. The specific activities of Sn-117m, Re-186 and Re-188 are 11 kBq/g, 2.6 MBq/g and 0.26 MBq/g in the saturation state, respectively. The produced amounts of the radioisotopes of tin and rhenium are sufficient for various laboratory tests in nuclear medicine.
引用
收藏
页码:867 / 872
页数:6
相关论文
共 6 条
  • [1] Comparison of the sizes of the potential therapeutic bone agents, the polyphosphonate PEI-MP labeled with 117mSn and 186Re
    Botelho, M. F.
    Zeevaart, J. R.
    Jansen, D. R.
    Turtoi, A.
    Abrantes, A. M.
    Kolar, Z. I.
    Neves, M. A.
    Schneeweiss, F. H. A.
    Krijger, G. C.
    Dormehl, I. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S335 - S335
  • [2] 188W/188Re GENERATOR PRODUCTION TECHNOLOGY FOR NUCLEAR MEDICINE
    Semenova, A. A.
    Baranov, N. G.
    Stepchenkov, D. V.
    Sulim, E. V.
    7TH INTERNATIONAL SYMPOSIUM ON TECHNETIUM AND RHENIUM - SCIENCE AND UTILIZATION, 2011, : 321 - 326
  • [3] Thermochromatographic separation of no-carrier-added 186Re or 188Re from tungsten targets relevant to nuclear medical applications
    Novgorodov, AF
    Bruchertseifer, F
    Brockmann, J
    Lebedev, NA
    Rösch, F
    RADIOCHIMICA ACTA, 2000, 88 (3-4) : 163 - 167
  • [4] Dosimetric evaluation of the polyphosphonate; PEI-MP labeled with 117mSn, 186Re and 99mTc as potential diagnosis/therapeutic bone agents
    Botelho, M. F.
    Zeevaart, J. R.
    Dormehl, I. C.
    Louw, W. K. A.
    Caramelo, F.
    Metello, L. F.
    Gomes, C. M.
    Neves, M.
    Sena, C.
    Abrantes, A. M.
    Kolar, Z. I.
    Krijger, G. C.
    Milner, R. J.
    Schneeweiss, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S309 - S309
  • [5] Production calculation of medical 67Ga, 111In , 117mSn, 131,125,123I, 133Xe, 153Sm, 159Gd, 188Re and 201Tl nuclei used for cancer diagnostics in single photon emission computed tomography via theoretical models
    Artun, Ozan
    INTERNATIONAL JOURNAL OF MODERN PHYSICS E, 2020, 29 (08):
  • [6] Investigation of some nuclear structure properties of 213Bi, 201Tl, 188Re, 186Re, 133Xe, 131I, 125I, 123I, 111In, 94Tc, 90Y, 67Ga, 67Cu, 62Cu, 61Cu, 55Co, and 48V nuclei used in SPECT in axial deformation
    Artun, Ozan
    TURKISH JOURNAL OF PHYSICS, 2020, 44 (03): : 256 - 272