Assessment of mitral annulus size and function by real-time 3-dimensional echocardiography in cardiomyopathy: Comparison with magnetic resonance imaging

被引:31
|
作者
Anwar, Ashraf M.
Soliman, Sarna I. I.
Nemes, Attila
Germans, Tjeerd
Krenning, Boudewijn J.
Geleijnse, Marcel L.
Van Rossum, Albert C.
ten Cate, Folkert J.
机构
[1] Erasmus Univ, Ctr Thorax, NL-3015 GD Rotterdam, Netherlands
[2] Al Azhar Univ, Al Husein Univ Hosp, Dept Cardiol, Cairo, Egypt
[3] Free Univ Amsterdam, Med Ctr, Amsterdam, Netherlands
[4] Univ Szeged, Dept Med 2, Szeged, Hungary
[5] Univ Szeged, Ctr Cardiol, Szeged, Hungary
关键词
D O I
10.1016/j.echo.2007.01.026
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. We sought to assess mitral annular (MA) size and function in hypertrophic cardiomyopathy (HCM) and dilated cardiomyopathy (HCM) using real-time 3-dimensional (3D) echocardiography (RT3DE). Methods: The study included 30 patients with HCM, 20 patients with DCM, and 30 control subjects. RT3DE measurements included end-systolic and end-diastolic MA area (MAA) (MAA(3D)), MA diameter(3D), MA fractional area change (MAFAC), and MA fractional shortening. In subgroup of 50 patients, magnetic resonance imaging (MRI) was used for MAA(MRI). and MA diameter(MRI) measurement. Results. End-diastolic MAA(3D) was larger in HCM than in control group (P < .0001). Higher MAFAC and MA fractional shortening were present in HCM than in control group (P =.001 and P =.006, respectively). End-systolic and end-diastolic MAA(3D),, in DCM were higher than in HCM and control groups (P < .0001). Lower MAFAC and MA fractional shortening were present in DCM than in HCM and control groups (P < .0001). MAFAC correlated well with left ventricular function in control subjects (r = 0.94, P < .0001), whereas correlation was less in DCM (r = 0.53, P =.02) and HCM (r = 0.42, P < .01). RT3DE and MRI measurements were comparable. Conclusion: RT3DE assessment of MA size and function in control subjects and patients with cardiomyopathy is accurate and well correlated with MRI.
引用
收藏
页码:941 / 948
页数:8
相关论文
共 50 条
  • [31] The evaluation of real-time 3-dimensional transthoracic echocardiography for the preoperative functional assessment of patients with mitral valve prolapse: A comparison with 2-dimensional transesophageal echocardiography
    Sharma, Rajan
    Mann, Jon
    Drummond, Linda
    Livesey, Steve A.
    Simpson, Iain A.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (08) : 934 - 940
  • [32] Assessment of tricuspid valve annulus size and shape with real-time three-dimensional echocardiography
    Anwar, A.
    Soliman, O.
    Geleijnse, M.
    Mcghie, J.
    Nemes, A.
    Ten Cate, F.
    EUROPEAN HEART JOURNAL, 2006, 27 : 707 - 707
  • [33] Real-time 3-dimensional echocardiography imaging for right ventricular endomyocardial biopsy: A comparison with fluoroscopy
    McCreery, CJ
    McCulloch, M
    Ahmad, M
    deFilippi, CR
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2001, 14 (09) : 927 - 933
  • [34] Assessment of the aortic valve by real-time 3-dimensional transesophageal echocardiography
    Kurosawa, K.
    Negishi, K.
    Tateno, R.
    Masuda, K.
    Obokata, M.
    Houjou, Y.
    Nakajima, M.
    Kurabayashi, M.
    EUROPEAN HEART JOURNAL, 2013, 34 : 1099 - 1099
  • [35] Quantitation of Mitral Annulus in Ischemic Mitral Regurgitation by 3-Dimensional Echocardiography
    Jiang, Yuwen
    Huang Guoqian
    Luo Xinping
    CIRCULATION, 2010, 122 (02) : E109 - E109
  • [36] Size, Shape, and Orientation of Dilated Annulus in Tricuspid Regurgitation: A Real-Time 3-Dimensional Transesophageal Echocardiography Study.
    Utsunomiya, Hiroto
    Harada, Yu
    Izumi, Kanako
    Susawa, Hitoshi
    Kinoshita, Mirai
    Itakura, Kiho
    Ikenaga, Hiroki
    Hidaka, Takayuki
    Kihara, Yasuki
    Shiota, Takahiro
    CIRCULATION, 2018, 138
  • [37] 4-Dimensional Modeling of the Mitral Valve by Real-Time 3-Dimensional Transesophageal Echocardiography
    Noack, Thilo
    Mukherjee, Chiro
    Ionasec, Razvan I.
    Voigt, Ingmar
    Kiefer, Philipp
    Vollroth, Marcel
    Hoebartner, Michael
    Ender, Joerg
    Misfeld, Martin
    Mohr, Friedrich-Wilhelm
    Seeburger, Joerg
    CIRCULATION, 2013, 128 (22)
  • [38] Value of real time three-dimensional echocardiography in patients with hypertrophic cardiomyopathy: Comparison with two-dimensional echocardiography and magnetic resonance imaging
    Bicudo, Leticia S.
    Tsutsui, Jeane M.
    Shiozaki, Afonso
    Rochitte, Carlos E.
    Arteaga, Edmundo
    Mady, Charles
    Ramires, Jose A. F.
    Mathias, Wilson, Jr.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2008, 25 (07): : 717 - 726
  • [39] Assessment of Left Ventricular Mass in Hypertrophic Cardiomyopathy Patients Bb Real-Time 3-Dimensional Echocardiography in Single-Beat Capture Image; Validation with Cardiac Magnetic Resonance Imaging
    Chang, Sung-A
    Lee, Sang-Chol
    Kim, Eun-Young
    Hahm, Seung-Hee
    Sohn, Myung-Kyun
    Kim, Eun-Young
    Park, Sung-Ji
    Choi, Jin-Oh
    Hahn, Joo-Yong
    Park, Seung Woo
    Choe, Yeon Hyeon
    Oh, Jae K.
    CIRCULATION, 2011, 124 (21)
  • [40] REAL-TIME 3-DIMENSIONAL IMAGING
    FORREST, AK
    PHOTOGRAMMETRIC RECORD, 1990, 13 (76): : 511 - 517