Study on heat transfer characteristics of a circular tube with polygonal twisted elements

被引:5
|
作者
Wang Zongyong [1 ]
Zhang Aoyu [1 ]
Meng Huibo [1 ]
机构
[1] Shenyang Univ Chem Technol, Sch Energy & Power Engn, Econ & Tech Dev Zone, 11 St, Shenyang 110142, Liaoning, Peoples R China
关键词
Twisted element; PEC value; Entransy efficiency; Field synergy; Simulation method; FRICTION FACTOR CHARACTERISTICS; TRANSFER ENHANCEMENT; ENTROPY GENERATION; PRESSURE-DROP; TAPE INSERTS; FLOW; LAMINAR; ENTRANSY; TWIN;
D O I
10.1007/s00231-020-02818-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper reported experimental and numerical simulation investigations on heat transfer characteristics of polygonal twisted elements in the constant wall temperature with Reynolds number (Re) ranging from 200 to 1800. In this study, the results revealed that the entransy efficiency (eta) increased with the polygonal twisted element's edge number increasing. Moreover, the highest entransy efficiency eta of the quadruple-edge continuous twisted element (QEC) heat exchange tube was 93.97%. Besides, the field synergy performance also showed a positive correlation with the element edge number. A maximum increase of 57% was observed in the field synergy number (Fc) of the QEC insert as compared with the plain tube while the performance evaluation criteria (PEC) had little relationship with the element edge number. In the case of the interlaced twisted elements, both the PEC value and the entransy efficiency eta were lower than the corresponding continuous ones. In addition, the Fc values were not apparent, of which the maximum difference was only 7% in the two cases(continuous twisted element and interlaced twisted element). In Re= 1800, when the d/D(the ratio of the twisted element diameter to the inner diameter of the tube) of the QEC heat exchange tube increased, the PEC values and Fc values both increased significantly. The maximum PEC value was 1.62 and the maximum Fc values was 202% higher than the plain tube. Subsequently, the entransy efficiency eta got the maximum value in the range of d/D = 0.375-0.75. The maximum entransy efficiency was 91.07%.
引用
收藏
页码:2107 / 2120
页数:14
相关论文
共 50 条
  • [1] Study on heat transfer characteristics of a circular tube with polygonal twisted elements
    Wang Zongyong
    Zhang Aoyu
    Meng Huibo
    Heat and Mass Transfer, 2020, 56 : 2107 - 2120
  • [2] Comparative study of heat transfer characteristics of a tube equipped with and twisted insert
    Paneliya, Sagar
    Khanna, Sakshum
    Mankad, Vishrut
    Ray, Abhijit
    Prajapati, Parth
    Mukhopadhyay, Indrajit
    MATERIALS TODAY-PROCEEDINGS, 2020, 28 : 1175 - 1180
  • [3] Friction and heat transfer characteristics of laminar swirl flow through a circular tube fitted with regularly spaced twisted-tape elements
    Saha, SK
    Dutta, A
    Dhal, SK
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (22) : 4211 - 4223
  • [4] Numerical study of heat transfer characteristics in a tube with regularly spaced twisted tape
    Nakaharai, Hiroyuki
    Takami, Satoshi
    Yokomine, Takehiko
    Ebara, Shinji
    Shimizu, Akihiko
    FUSION SCIENCE AND TECHNOLOGY, 2007, 52 (04) : 855 - 859
  • [5] Convective Heat Transfer Enhancement in a Circular Tube Using Twisted Tape
    Lin, Zhi-Min
    Wang, Liang-Bi
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2009, 131 (08): : 1 - 12
  • [6] A study of the heat transfer characteristics of a laser rod in a concentric circular tube
    Z. Li
    X. Huai
    Y. Tao
    Applied Physics B, 2007, 87 : 301 - 309
  • [7] A study of the heat transfer characteristics of a laser rod in a concentric circular tube
    Li, Z.
    Huai, X.
    Tao, Y.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2007, 87 (02): : 301 - 309
  • [8] Experimental investigation of heat transfer and flow friction in a circular tube fitted with regularly spaced twisted tape elements
    Eiamsa-ard, Smith
    Thianpong, Chinaruk
    Promvonge, Pongjet
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2006, 33 (10) : 1225 - 1233
  • [9] The effect of off-center placement of twisted tape on flow and heat transfer characteristics in a circular tube
    Li Wang
    Peiyong Ni
    Guannan Xi
    Scientific Reports, 11
  • [10] The effect of off-center placement of twisted tape on flow and heat transfer characteristics in a circular tube
    Wang, Li
    Ni, Peiyong
    Xi, Guannan
    SCIENTIFIC REPORTS, 2021, 11 (01)