Building-to-grid predictive power flow control for demand response and demand flexibility programs

被引:89
|
作者
Razmara, M. [1 ]
Bharati, G. R. [2 ]
Hanover, Drew [1 ]
Shahbakhti, M. [1 ]
Paudyal, S. [2 ]
Robinett, R. D., III [1 ]
机构
[1] Michigan Technol Univ, Mech Engn Engn Mech, Houghton, MI 49931 USA
[2] Michigan Technol Univ, Dept Elect & Comp Engn, Houghton, MI 49931 USA
基金
美国国家科学基金会;
关键词
Demand response; Demand flexibility; Building to Grid (B2G); Building predictive control; Solar PV panel integration; Energy storage system integration; Monte-Carlo simulation; RULE-BASED CONTROL; MODEL; SYSTEM;
D O I
10.1016/j.apenergy.2017.06.040
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Demand Side Management (DSM) provides ancillary service to the electric grid by modifying customers electricity demand. Demand Response (DR) and Demand Flexibility (DF) programs from buildings are well-adopted ancillary services to reduce the peak demand in grids by altering the power consumption strategy. Heating, Ventilation and Air-Conditioning (HVAC) systems are one of the largest energy demands in commercial buildings. In addition, HVAC systems are flexible to provide DR service to the grid. In this study, two common configuration topologies of building integration with Energy Storage Systems (ESS) and renewables are considered. A real-time optimization framework based on Model Predictive Control (MPC) is designed to control the power flow from the grid, solar Photovoltaic (PV) panels, and ESS to a commercial building with HVAC systems. The MPC framework uses the inherent thermal mass storage of the building and the ESS as a means to provide DR. Deterministic and probabilistic analysis are studied to investigate the effectiveness of the proposed framework on Building-to-Grid (B2G) systems. Our deterministic results show that the proposed optimization and control framework for B2G systems can significantly reduce the maximum load ramp-rate of the electric grid to prevent duck-curve problems associated with increase in solar PV penetration into the grid. Based on probabilistic results, even under prediction uncertainties, electricity cost saving and ramp-rate reduction is achievable. The results show that this DR service does not affect the building indoor climate in a way noticeable to humans and its effect on the operational building costs is reduced. The B2G simulation testbed in this paper is based on the experimental data obtained from an office building, PV panels, and battery packs integrated with a three-phase unbalanced distribution test feeder. A Monte-Carlo simulation is carried out to account for uncertainties of the proposed method. Both deterministic and stochastic analyses show the effectiveness of the proposed predictive power flow control to decrease the building operation electricity costs and load ramp-rates. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:128 / 141
页数:14
相关论文
共 50 条
  • [1] Enabling Demand Response Programs via Predictive Control of Building-to-Grid Systems Integrated with PV Panels and Energy Storage Systems
    Razmara, Meysam
    Bharati, Guna R.
    Hanover, Drew
    Shahbakhti, Mahdi
    Paudyal, Sumit
    Robinett, Rush D., III
    [J]. 2017 AMERICAN CONTROL CONFERENCE (ACC), 2017, : 56 - 61
  • [2] Building-to-grid flexibility: Modelling and assessment metrics for residential demand response from heat pump aggregations
    Zhang, Lingxi
    Good, Nicholas
    Mancarella, Pierluigi
    [J]. APPLIED ENERGY, 2019, 233 : 709 - 723
  • [3] Building-to-grid optimal control of integrated MicroCSP and building HVAC system for optimal demand response services
    Toub, Mohamed
    Robinett, Rush D., III
    Shahbakhti, Mahdi
    [J]. OPTIMAL CONTROL APPLICATIONS & METHODS, 2023, 44 (02): : 866 - 884
  • [4] Predictive control of a combined heat and power plant for grid flexibility under demand uncertainty
    De Lorenzi, Andrea
    Gambarotta, Agostino
    Marzi, Emanuela
    Morini, Mirko
    Saletti, Costanza
    [J]. APPLIED ENERGY, 2022, 314
  • [5] Economic model predictive control for demand flexibility of a residential building
    Finck, Christian
    Li, Rongling
    Zeiler, Wim
    [J]. ENERGY, 2019, 176 : 365 - 379
  • [6] Distributed model predictive control for joint coordination of demand response and optimal power flow with renewables in smart grid
    Shi, Ye
    Tuan, Hoang Duong
    Savkin, Andrey, V
    Lin, Chin-Teng
    Zhu, Jian Guo
    Poor, H. Vincent
    [J]. APPLIED ENERGY, 2021, 290
  • [7] Building power demand response methods toward smart grid
    Wang, Shengwei
    Xue, Xue
    Yan, Chengchu
    [J]. HVAC&R RESEARCH, 2014, 20 (06): : 665 - 687
  • [8] Predictive control based assessment of building demand flexibility in fixed time windows
    Vasak, Mario
    Banjac, Anita
    Hure, Nikola
    Novak, Hrvoje
    Kovacevic, Marko
    [J]. APPLIED ENERGY, 2023, 329
  • [9] Flexibility Control in Autonomous Demand Response by Optimal Power Tracking
    Rheinberger, Klaus
    Kepplinger, Peter
    Preissinger, Markus
    [J]. ENERGIES, 2021, 14 (12)
  • [10] Model predictive control for building active demand response systems
    Lauro, Fiorella
    Moretti, Fabio
    Capozzoli, Alfonso
    Panzieri, Stefano
    [J]. SUSTAINABILITY IN ENERGY AND BUILDINGS: PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE SEB-15, 2015, 83 : 494 - 503