The Limulus Amebocyte Lysate assay may be unsuitable for detecting endotoxin in blood of healthy female subjects

被引:22
|
作者
Gnauck, Anne [1 ]
Lentle, Roger G. [1 ]
Kruger, Marlena C. [1 ]
机构
[1] Massey Univ, Inst Food Nutr & Human Hlth, Palmerston North 4442, New Zealand
关键词
Endotoxin; LAL assay; Limulus Amebocyte Lysate assay; Serum; LIPOPOLYSACCHARIDE (LPS)-BINDING PROTEIN; BACTERIAL-ENDOTOXIN; OBESITY; LIPOPROTEINS; INHIBITION; COLLECTION; PLASMA; SERUM;
D O I
10.1016/j.jim.2014.11.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We examined the factors that may influence the outcome of the Limulus Amebocyte Lysate (LAL) assay, when it is used for quantifying Gram-negative bacterial endotoxin, also referred to as lipopolysaccharide (LPS), in samples of human blood. We found that the method recommended by the manufacturers, based on the reaction time, was inaccurate with any type of serum samples due to the slowing of the initial phase of reaction, likely by serum proteins. We describe an alternative method that is more accurate for use with heated serum samples. Further, we found that components of fresh serum irreversibly sequester endotoxin but that this action may be largely prevented by dilution and heating, but only if this occurs prior to the addition of endotoxin. The tests also indicated that a number of types of proprietary plastic vacutainers appeared to contain significant amounts of endotoxin. However, even when appropriate blood collection containers and calculation methods were used, the levels of endotoxin in serum samples detected by LAL assay were unlikely to reflect the total quantities of endotoxin in that sample and more likely to reflect the capacity of a given serum sample to sequester endotoxin. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:146 / 156
页数:11
相关论文
共 50 条
  • [1] LIMULUS AMEBOCYTE LYSATE ENDOTOXIN ASSAY - CURRENT STATUS
    PEARSON, FC
    AMERICAN JOURNAL OF MEDICAL TECHNOLOGY, 1979, 45 (08): : 704 - 709
  • [2] MODIFIED MICROMETHOD OF THE LIMULUS AMEBOCYTE LYSATE ASSAY FOR ENDOTOXIN
    MELVAER, KL
    FYSTRO, D
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1982, 43 (02) : 493 - 494
  • [3] IMPROVED MICROTECHNIQUE FOR ENDOTOXIN ASSAY BY THE LIMULUS AMEBOCYTE LYSATE TEST
    GARDI, A
    ARPAGAUS, GR
    ANALYTICAL BIOCHEMISTRY, 1980, 109 (02) : 382 - 385
  • [4] LIMULUS AMEBOCYTE LYSATE - DIAGNOSTIC ASSAY OF ENDOTOXIN INHIBITION BY SERUM
    BUCKLIN, A
    AMERICAN ZOOLOGIST, 1983, 23 (04): : 976 - 976
  • [5] Endotoxin recovery using limulus amebocyte lysate (LAL) assay
    Bolden, Jay S.
    Warburton, Rob E.
    Phelan, Robert
    Murphy, Marie
    Smith, Kelly R.
    De Felippis, Michael R.
    Chen, Dayue
    BIOLOGICALS, 2016, 44 (05) : 434 - 440
  • [6] INACTIVATION OF ENDOTOXIN BY LIMULUS AMEBOCYTE LYSATE
    NACHUM, R
    SIEGEL, SE
    SULLIVAN, JD
    WATSON, SW
    JOURNAL OF INVERTEBRATE PATHOLOGY, 1978, 32 (01) : 51 - 58
  • [7] THE LIMULUS AMEBOCYTE LYSATE ASSAY
    SPAGNA, VA
    PRIOR, RB
    AMERICAN FAMILY PHYSICIAN, 1980, 22 (03) : 125 - 128
  • [8] THE LIMULUS AMEBOCYTE LYSATE TEST FOR ENDOTOXIN
    PEARSON, FC
    WEARY, M
    BIOSCIENCE, 1980, 30 (07) : 461 - 464
  • [9] SINGLE-STEP, CHROMOGENIC LIMULUS AMEBOCYTE LYSATE ASSAY FOR ENDOTOXIN
    LINDSAY, GK
    ROSLANSKY, PF
    NOVITSKY, TJ
    JOURNAL OF CLINICAL MICROBIOLOGY, 1989, 27 (05) : 947 - 951
  • [10] SPECIFIC ASSAY FOR ENDOTOXIN USING IMMOBILIZED HISTIDINE AND LIMULUS AMEBOCYTE LYSATE
    MINOBE, S
    NAWATA, M
    WATANABE, T
    SATO, T
    TOSA, T
    ANALYTICAL BIOCHEMISTRY, 1991, 198 (02) : 292 - 297