摘要
Solar multiple (SM) and thermal storage capacity are two key design parameters for revealing the performance of direct steam generation (DSG) solar power tower plant. In the case of settled land area, SM and thermal storage capacity can be optimized to obtain the minimum levelized cost of electricity (LCOE) by adjusting the power generation output. Taking the dual-receiver DSG solar power tower plant with a given size of solar field equivalent electricity of 100 MWe in Sevilla as a reference case, the minimum LCOE is 21.77A (sic)/kWh(e) with an SM of 1.7 and a thermal storage capacity of 3 h. Besides Sevilla, two other sites are also introduced to discuss the influence of annual DNI. When compared with the case of Sevilla, the minimum LCOE and optimal SM of the San Jose site change just slightly, while the minimum LCOE of the Bishop site decreases by 32.8% and the optimal SM is reduced to 1.3. The influence of the size of solar field equivalent electricity is studied as well. The minimum LCOE decreases with the size of solar field, while the optimal SM and thermal storage capacity still remain unchanged. In addition, the sensitivity of different investment in sub-system is investigated. In terms of optimal SM and thermal storage capacity, they can decrease with the cost of thermal storage system but increase with the cost of power generation unit.
引用
收藏
页码:461 / 471
页数:11
相关论文
共 50 条
  • [1] Impacts of solar multiple on the performance of direct steam generation solar power tower plant with integrated thermal storage
    Yan Luo
    Xiaoze Du
    Lijun Yang
    Chao Xu
    Muhammad Amjad
    [J]. Frontiers in Energy, 2017, 11 : 461 - 471
  • [2] A Direct Steam Generation Solar Power Plant With Integrated Thermal Storage
    Birnbaum, Juergen
    Eck, Markus
    Fichtner, Markus
    Hirsch, Tobias
    Lehmann, Dorothea
    Zimmermann, Gerhard
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (03): : 0310141 - 0310145
  • [3] Performance of a direct steam generation solar thermal power plant for electricity production as a function of the solar multiple
    Montes, M. J.
    Abanades, A.
    Martinez-Val, J. M.
    [J]. SOLAR ENERGY, 2009, 83 (05) : 679 - 689
  • [4] Exploring the performance of an innovative integrated solar tower power plant with hydrogen generation and storage
    Mirbagheri, Mohammad Hashem
    Baniasadi, Ehsan
    Genceli, Hadi
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (99) : 39271 - 39285
  • [5] Thermal storage concept for solar thermal power plants with direct steam generation
    Seitz, M.
    Cetin, P.
    Eck, M.
    [J]. PROCEEDINGS OF THE SOLARPACES 2013 INTERNATIONAL CONFERENCE, 2014, 49 : 993 - 1002
  • [6] SIMULATION OF DIRECT STEAM POWER TOWER CONCENTRATED SOLAR PLANT
    Neises, Ty
    Wagner, Michael J.
    [J]. PROCEEDINGS OF THE ASME 6TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY - 2012, PTS A AND B, 2012, : 497 - 505
  • [7] The comparative analysis on thermal storage systems for solar power with direct steam generation
    Guo, Jiangfeng
    Huai, Xiulan
    Cheng, Keyong
    [J]. RENEWABLE ENERGY, 2018, 115 : 217 - 225
  • [8] Performance analysis of a Kalina cycle for a central receiver solar thermal power plant with direct steam generation
    Modi, Anish
    Haglind, Fredrik
    [J]. APPLIED THERMAL ENGINEERING, 2014, 65 (1-2) : 201 - 208
  • [9] Dynamic simulation of steam generation system in solar tower power plant
    Zhang, Qiang
    Wang, Zhiming
    Du, Xiaoze
    Yu, Gang
    Wu, Hongwei
    [J]. RENEWABLE ENERGY, 2019, 135 : 866 - 876
  • [10] Steam temperature stability in a direct steam generation solar power plant
    Birnbaum, Juergen
    Feldhoff, Jan Fabian
    Fichtner, Markus
    Hirsch, Tobias
    Jocker, Markus
    Pitz-Paal, Robert
    Zimmermann, Gerhard
    [J]. SOLAR ENERGY, 2011, 85 (04) : 660 - 668