The influence of binary pozzolanic replacements on the durability and corrosion performance of reinforced concrete

被引:4
|
作者
Mossalam, Essam [1 ]
Ahmed, Nivin M. [2 ]
Souaya, Eglal M. R. [3 ]
El-Sabbagh, Basil [1 ]
机构
[1] Housing & Bldg Natl Res Ctr, Dept Raw Mat & Technol Proc Res, Cairo, Egypt
[2] Natl Res Ctr, Dept Polymers & Pigments, Giza, Egypt
[3] Ain Shams Univ, Dept Inorgan Chem, Cairo, Egypt
关键词
EIS; Durability; Reinforced concrete; Corrosion; Silica fume; Anticorrosive paints; Meta-kaolin; Ternary replacements; SILICA FUME; METAKAOLIN; RESISTANCE; PHOSPHATE; STRENGTH; DESIGN;
D O I
10.1108/PRT-02-2020-0006
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Purpose The purpose of this research is to study the physical and mechanical properties beside the durability of concrete as well as corrosion resistance of reinforced concrete by replacing Ordinary Portland cement (OPC) with different ratios of silica fume and meta-kaolin and applying two paint formulations to enhance corrosion resistance and mechanical properties. In this work, modified concrete mixes containing pozzolanic materials of industrial wastes such as silica fume (SF) with ratios ranging between (0, 10 and 15%) and calcined raw material such as meta-kaolin (MK) with ratios (0, 3, 5 and 10%), were introduced using water binder ratio (w/b) 0.45 to study their effect on the physico-mechanical properties and durability of concrete as well as corrosion protection performance of reinforced concrete. Two paint formulations containing the same ingredients except that one of them is free from talc (G1) and the other contains talc (G2) were applied on the rebars embedded in these modified mixes. Talc is known to offer high pH to the surrounding media. Design/methodology/approach Modified concrete mixes containing the coated reinforced concrete steel with the different paint formulations in presence and absence of talc were tested, and the corrosion behavior was studied using electrochemical impedance spectroscopy (EIS) in 3.5% NaCl, and the concrete mixes were also tested through their compressive strength, chloride permeability, scanning electron microscope/energy dispersive X-ray analysis and bond strength. Findings The results revealed that the hardened reinforced concrete mix containing 10% SF with 5% MK with embedded rebars coated with G2 (paint containing talc) was the best concrete system which offers concrete sustainability besides high corrosion protection performance, i.e. presence of talc in the paints combined with the effect of cement blended with SF and MK showed positive effect on the reinforced concrete properties that leads to more durability and workability. Originality/value The integrity of using two efficient methods of corrosion protection beside the effect of the different replacements in concrete mixes containing coated reinforced concrete steel with paint formulations free from talc (G1) and others containing talc (G2), which lead to fatal changes in the pH of the surrounding media (i.e. concrete which has high alkaline pH) to achieve good concrete properties aside with convenient paint formulations together.
引用
收藏
页码:19 / 31
页数:13
相关论文
共 50 条
  • [1] Influence of GGBS on durability and corrosion behavior of reinforced concrete
    Cheng, A
    Huang, R
    Wu, JK
    Chen, CH
    MATERIALS CHEMISTRY AND PHYSICS, 2005, 93 (2-3) : 404 - 411
  • [2] Influence of melted incinerator ash on durability and corrosion behaviour of reinforced concrete
    Cheng, T-C
    Cheng, A.
    Huang, R.
    Hwang, H.
    Lin, W-T
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART L-JOURNAL OF MATERIALS-DESIGN AND APPLICATIONS, 2012, 226 (L1) : 42 - 51
  • [3] Durability performance of self-compacting concrete using binary and ternary blended pozzolanic and waste material
    Natarajan, Karthiga Shenbagam
    Ashokan, Mohanraj
    Vellaipandian, Kannan
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2023, 8 (10)
  • [4] Durability performance of self-compacting concrete using binary and ternary blended pozzolanic and waste material
    Karthiga Shenbagam Natarajan
    Mohanraj Ashokan
    Kannan Vellaipandian
    Innovative Infrastructure Solutions, 2023, 8
  • [6] The influence of internal corrosion on the durability of concrete
    Lowinska-Kluge, A.
    Blaszczynski, T.
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2012, 12 (02) : 219 - 227
  • [7] Pozzolanic additions for durability of concrete structures
    Bertolini, Luca
    Carsana, Maddalena
    Frassoni, Massimiliano
    Gelli, Massimo
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-CONSTRUCTION MATERIALS, 2011, 164 (06) : 283 - 291
  • [8] Influence of reinforcement corrosion on fire performance of reinforced concrete beams
    Ba, Guangzhong
    Miao, Jijun
    Zhang, Weiping
    Liu, Jialiang
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 213 : 738 - 747
  • [9] DURABILITY OF REINFORCED AND PRESTRESSED MASONRY - CORROSION OF STEEL IN CONCRETE
    BEEBY, AW
    TRANSACTIONS AND JOURNAL OF THE BRITISH CERAMIC SOCIETY, 1982, 81 (04): : 97 - 100
  • [10] SIMULATION OF THE EFFECTS OF POZZOLANIC ADDITIVES AND CORROSION INHIBITOR ON THE CORROSION OF REINFORCED CONCRETE BY ARTIFICIAL NEURAL NETWORKS
    Afshar, Alireza
    Nobakhti, Amirhossein
    Shokrgozar, Ali
    Afshar, Amirhossein
    REVISTA ROMANA DE MATERIALE-ROMANIAN JOURNAL OF MATERIALS, 2019, 49 (04): : 535 - 543