Estimation of the rheological curve of HPAM solutions from measurements using the Brookfield viscometer

被引:3
|
作者
Perez, Eduar [1 ,2 ]
Alviso, Dario [1 ,3 ]
Manrique, Eduardo [4 ]
Artana, Guillermo [1 ]
机构
[1] Univ Buenos Aires, Fac Ingn, Lab Fluidodinam, CONICET, Paseo Colon 850, Buenos Aires, Argentina
[2] Univ Norte, Dept Mech Engn, Barranquilla, Colombia
[3] Univ Maria Auxiliadora, Mariano Roque Alonso, Paraguay
[4] Ecopetrol Inst Colombiano Petr, Santander, Colombia
关键词
Enhanced oil recovery; Polymers; Acrylamide; Viscosity; PERFORMANCE; VISCOSITY; POLYMERS;
D O I
10.1016/j.petrol.2022.110793
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In recent studies, Jouenne and Levache (2020) proposed a rheological model for polymeric solutions used in enhanced oil recovery, based essentially on a variable obtained as the product of the intrinsic viscosity of the solution and the concentration of the polymer. Using this variable, the authors propose expressions in which is possible to predict the coefficients of Carreau-Yasuda's law that are of interest: the viscosity under zero shear regime eta(0), the power index eta, and the relaxation time lambda. In this work, the robustness of this model is improved using a machine learning technique and a larger database than the one previously considered. Based on this enhanced model, a technique is proposed to estimate the intrinsic viscosity of the solutions and the parameters of Carreau-Yasuda's law using only the measurement of viscosity at a shear rate of 7.3 s(-1). The results obtained with this approach are compared to those issued from experimental data finding satisfactory results. The use of this strategy is of particular interest for field studies or laboratories that only have as available instruments the Brookfield viscometer.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Estimation of the Rheological Curve of Hpam Solutions from Measurements Using the Brookfield Viscometer
    Pérez, Eduar
    Alviso, Dario
    Manrique, Eduardo
    Artana, Guillermo
    SSRN, 2022,
  • [2] A simple model of the rheological curve of HPAM solutions at different temperatures
    Perez, Eduar
    Alviso, Dario
    Carmona, Mauricio
    Manrique, Eduardo
    Artana, Guillermo
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [3] Using a Brookfield Viscometer for Determining the Rheological Properties of Newtonian, Plastic or Pseudoplastic Media.
    Fournier-Villalon, P.
    Bertrand, J.
    Couderc, J.P.
    Entropie Paris, 1984, 20 (120): : 45 - 49
  • [4] A Study on the Rheological Performance of a Nanoclay-Modified Asphalt Binder Using the Brookfield Viscometer and Dynamic Shear Rheometer
    Ashish, Prabin Kumar
    Singh, Dharamveer
    Bohm, Siva
    RESILIENT RAILROAD MATERIALS AND STRUCTURES TO MITIGATE CLIMATE CHANGE, 2016, (268): : 9 - 15
  • [5] Determination of Rheological Parameters from Measurements on a Viscometer with Coaxial Cylinders
    Rieger, F.
    ACTA POLYTECHNICA, 2006, 46 (03) : 42 - 51
  • [6] Estimation of rheological parameters using velocity measurements
    Park, H. M.
    Hong, S. M.
    Lim, J. Y.
    CHEMICAL ENGINEERING SCIENCE, 2007, 62 (23) : 6806 - 6815
  • [7] Determination of Rheological Parameters from Measurements on a Viscometer with Coaxial Cylinders - Choice of the Reference Radius
    Rieger, F.
    ACTA POLYTECHNICA, 2006, 46 (06) : 22 - 24
  • [8] Estimation of Taper Curve Using Stand Variables and Sample Tree Measurements
    Kilkki, Pekka
    Lappi, Juha
    SCANDINAVIAN JOURNAL OF FOREST RESEARCH, 1987, 2 (1-4) : 121 - 126
  • [9] APPARENT YIELD STRESS ESTIMATION IN XANTHAN GUM SOLUTIONS AND FERMENTATION BROTHS USING A LOW-COST VISCOMETER
    HANNOTE, M
    FLORES, F
    TORRES, L
    GALINDO, E
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1991, 45 (03): : B49 - B56
  • [10] Apparent yield stress estimation in xanthan gum solutions and fermentation broths using a low-cost viscometer
    Hannote, M.
    Flores, F.
    Torres, L.
    Galindo, E.
    Chemical engineering journal, 1991, 45 (03):