Model to Balance an Acceptable Radon Level Indoors

被引:2
|
作者
Rasmussen, Torben Valdbjorn [1 ]
Cornelius, Thomas [1 ]
机构
[1] Aalborg Univ, Dept Civil Engn & Construct Management, BUILD, AC Meyers Vaenge 15, DK-2450 Copenhagen, Denmark
关键词
model; radon; soil gas; indoor materials; penetration; ventilation; indoor air quality;
D O I
10.3390/buildings12040447
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A theoretical model is presented for balancing an acceptable radon concentration in indoor air. The infiltration of radon from the ground to the indoor air can be controlled by barriers or by lowering the air pressure at the lower zone of the ground slab. Indoor air with a radon concentration higher than that of outdoor air can further be controlled through the effective dilution of indoor air with outdoor air. The theory estimates the allowed radon infiltration from the ground to balance radon at an acceptable level indoors for a given ventilation rate, considering the radon contribution to the indoor air from indoor materials, building materials and the interior. A method using this theory is presented, identifying the necessary airtightness required for a radon barrier to balance the acceptable radon concentration for a building. Barriers include commercially used system solutions, such as bitumen-based radon blockers, wet-room membranes, reinforced fixed mortar pastes, and polyethene membranes. An acceptable indoor radon concentration of between 100 and 300 Bq/m(3) in indoor air is used. Barriers are evaluated by their ability to prevent soil gas penetration from the ground in combination with their effect on the building durability, as barriers may create a far more vulnerable building.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Use of radon barriers to reach an acceptable radon level
    Rasmussen, Torben Valdbjorn
    Cornelius, Thomas
    12TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB 2020), 2020, 172
  • [2] VERIFYING A MODEL OF RADON DECAY PRODUCT BEHAVIOR INDOORS
    BRUNO, RC
    HEALTH PHYSICS, 1983, 45 (02): : 471 - 480
  • [3] Ventilation model for elevated radon decay product levels indoors
    Rolle, R
    Lettner, H
    Hofmann, W
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 2, 1996, : B137 - B137
  • [4] The RAGENA dynamic model of radon generation, entry and accumulation indoors
    Font, L
    Baixeras, C
    SCIENCE OF THE TOTAL ENVIRONMENT, 2003, 307 (1-3) : 55 - 69
  • [5] A STUDY OF RADON 222 TRANSFER INDOORS
    MAXIMILIEN, R
    ROBE, MC
    ARCHIMBAUD, M
    RADIOPROTECTION, 1985, 20 (01) : 45 - 60
  • [6] METROLOGY OF THE RADON RISK INDOORS AND OUTDOORS
    PINEAU, JF
    ZETTWOOG, P
    RADIOPROTECTION, 1989, 24 (04) : 287 - 300
  • [7] RADON AND RADON DAUGHTER EVALUATION IN A NATURAL RADIOACTIVITY SURVEY INDOORS
    VENUTI, GC
    RISICA, S
    ANTONINI, A
    BORIO, R
    GOBBI, G
    LEOGRANDE, MP
    SCIENCE OF THE TOTAL ENVIRONMENT, 1985, 45 (OCT) : 373 - 380
  • [8] ALPHATRON RADON OINTMENT NOT ACCEPTABLE
    不详
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1949, 140 (08): : 677 - 677
  • [9] Results Of The National Survey On Radon Indoors In Albania
    Bode, Kozeta
    Bylyku, Elida
    Cfarku, Florinda
    Mucollari, Irena
    Shyti, Manjola
    7TH INTERNATIONAL CONFERENCE OF THE BALKAN PHYSICAL UNION VOLS 1 AND 2, 2009, 1203 : 672 - +
  • [10] Reducing the risks from radon indoors: an IAEA perspective
    Boal, T.
    Colgan, P. A.
    RADIATION PROTECTION DOSIMETRY, 2014, 160 (1-3) : 2 - 3