Evaluating the resilience of a full-scale down-flow hanging sponge reactor to shock-loadings

被引:3
|
作者
Onodera, Takashi [1 ]
Okubo, Tsutomu [2 ]
Takayama, Daisuke [3 ]
Syutsubo, Kazuaki [1 ]
Yamaguchi, Takashi [3 ]
Uemura, Shigeki [2 ]
Ohashi, Akiyoshi [4 ]
Harada, Hideki [5 ]
机构
[1] Natl Inst Environm Studies, Reg Environm Conservat Div, 16-2 Onogawa, Tsukuba, Ibaraki 3058506, Japan
[2] Kisarazu Coll, Natl Inst Technol, Dept Civil & Environm Engn, 2-11-1 Kiyomidaihigashi, Kisarazu, Chiba 2920041, Japan
[3] Nagaoka Univ Technol, Dept Civil & Environm Engn, 1603-1 Kamitomioka, Nagaoka, Niigata 9402188, Japan
[4] Hiroshima Univ, Dept Social & Environm Engn, 1-4-1 Kagamiyama Higashi, Hiroshima 7398527, Japan
[5] Tohoku Univ, New Ind Creat Hatchery Ctr, Aoba Ku, 6-6-04 Aza Aoba, Sendai, Miyagi 9808579, Japan
关键词
developing countries; down-flow hanging sponge (DHS); sewage treatment; shock-loading; UASB post-treatment; SEWAGE-TREATMENT SYSTEM; MUNICIPAL WASTE-WATER; UASB REACTOR; DHS REACTOR; PERFORMANCE EVALUATION; SLUDGE; POSTTREATMENT; COMBINATION; BANGKOK; CUBES;
D O I
10.2166/wpt.2021.118
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
The effect of shock-loading on the performance of a full-scale down-flow hanging sponge (DHS), used to treat effluent from an up-flow anaerobic sludge blanket treating municipal sewage, was evaluated. This full-scale DHS reactor comprises a polyurethane sponge that retains the sludge. It has a capacity of 500 m(3)/day and, at the time of this study, had been operating at a sewage treatment plant in India for more than 1,300 days. The DHS reactor was exposed to shock-loadings of organics at double the normal rate for 400 min under summer and winter conditions. The results showed that the DHS reactor maintained stable operation under the organic shock-loading and that it returned to a steady state soon after restart, confirming that the reactor was resilient to organic shock-loadings.
引用
收藏
页码:223 / 233
页数:11
相关论文
共 50 条
  • [1] Evaluation of the resilience of a full-scale down-flow hanging sponge reactor to long-term outages at a sewage treatment plant in India
    Onodera, Takashi
    Takayama, Daisuke
    Ohashi, Akiyoshi
    Yamaguchi, Takashi
    Uemura, Shigeki
    Harada, Hideki
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2016, 181 : 832 - 837
  • [2] Full-scale application of a down-flow hanging sponge reactor combined with a primary sedimentation basin for domestic sewage treatment
    Okubo, Tsutomu
    Tagawa, Tadashi
    Takahashi, Masanobu
    Iguchi, Akinori
    Oshiki, Mamoru
    Araki, Nobuo
    Kubota, Kengo
    Tawfik, Ahmed
    Uemura, Shigeki
    Harada, Hideki
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2022, 45 (04) : 701 - 709
  • [3] Full-scale application of a down-flow hanging sponge reactor combined with a primary sedimentation basin for domestic sewage treatment
    Tsutomu Okubo
    Tadashi Tagawa
    Masanobu Takahashi
    Akinori Iguchi
    Mamoru Oshiki
    Nobuo Araki
    Kengo Kubota
    Ahmed Tawfik
    Shigeki Uemura
    Hideki Harada
    Bioprocess and Biosystems Engineering, 2022, 45 : 701 - 709
  • [4] Long-term performance evaluation of down-flow hanging sponge reactor regarding nitrification in a full-scale experiment in India
    Onodera, Takashi
    Okubo, Tsutomu
    Uemura, Shigeki
    Yamaguchi, Takashi
    Ohashi, Akiyoshi
    Harada, Hideki
    BIORESOURCE TECHNOLOGY, 2016, 204 : 177 - 184
  • [5] Recovery of partial nitrification in a down-flow hanging sponge reactor by salt shock loading
    Matsubayashi, Miri
    Harada, Hideki
    Okubo, Tsutomu
    Uemura, Shigeki
    Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering, 2016, 51 (03): : 262 - 266
  • [6] Recovery of partial nitrification in a down-flow hanging sponge reactor by salt shock loading
    Matsubayashi, Miri
    Harada, Hideki
    Okubo, Tsutomu
    Uemura, Shigeki
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2016, 51 (03): : 262 - 266
  • [7] The effect of salinity on nitrite accumulation in a down-flow hanging sponge reactor
    Natori, T.
    Takemura, Y.
    Harada, H.
    Abe, K.
    Ohashi, A.
    Kimura, M.
    Yamaguchi, T.
    Okubo, T.
    Uemura, S.
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2012, 87 (10) : 1466 - 1472
  • [8] Enhancement of denitrification in a down-flow hanging sponge reactor by effluent recirculation
    Ikeda, N.
    Natori, T.
    Okubo, T.
    Sugo, A.
    Aoki, M.
    Kimura, M.
    Yamaguchi, T.
    Harada, H.
    Ohashi, A.
    Uemura, S.
    WATER SCIENCE AND TECHNOLOGY, 2013, 68 (03) : 591 - 598
  • [9] Estimation of microbial community for denitrification in the down-flow hanging sponge (DHS) reactor
    Tanikawa, Daisuke
    Sonaka, Hideaki
    Kadotani, Moe
    Sugimori, Fuma
    Motokawa, Daisuke
    Ihara, Sota
    Itoiri, Yuya
    Kimura, Zen-Ichiro
    INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2020, 153 (153)
  • [10] A pilot-scale study on a down-flow hanging sponge reactor for septic tank sludge treatment
    Machdar, Izarul
    Muhammad, Syaifullah
    Onodera, Takashi
    Syutsubo, Kazuaki
    ENVIRONMENTAL ENGINEERING RESEARCH, 2018, 23 (02) : 195 - 204