Impact assessment of an automated drug-dispensing system in a tertiary hospital

被引:20
|
作者
de-Carvalho, Debora [1 ]
Alvim-Borges, Jose Luiz [2 ]
Toscano, Cristiana Maria [3 ]
机构
[1] HSL, Farm, Sao Paulo, SP, Brazil
[2] HSL, Inst Ensino & Pesquisa, Sao Paulo, SP, Brazil
[3] Univ Fed Goias, Inst Patol Trop & Saude Publ, Dept Saude Colet, Goiania, Go, Brazil
关键词
Pharmacy; Cost and Cost Analysis; Automated Drug-Dispensing Systems; Impact; INTENSIVE-CARE-UNIT; MEDICATION ADMINISTRATION ERRORS; IMPLEMENTATION; EVENTS; SAFETY; INTERVENTIONS; SETTINGS;
D O I
10.6061/clinics/2017(10)07
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: To evaluate the costs and patient safety of a pilot implementation of an automated dispensing cabinet in a critical care unit of a private tertiary hospital in Sao Paulo/Brazil. METHODS: This study considered pre- (January-August 2013) and post-(October 2013-October 2014) intervention periods. We considered the time and cost of personnel, number of adverse events, audit adjustments to patient bills, and urgent requests and returns of medications to the central pharmacy. Costs were evaluated based on a 5-year analytical horizon and are reported in Brazilian Reals (R$) and US dollars (USD). RESULTS: The observed decrease in the mean number of events reported with regard to the automated drug-dispensing system between pre- and post-implementation periods was not significant. Importantly, the numbers are small, which limits the power of the mean comparative analysis between the two periods. A reduction in work time was observed among the nurses and administrative assistants, whereas pharmacist assistants showed an increased work load that resulted in an overall 6.5 hours of work saved/day and a reduction of R$ 33,598 (USD 14,444) during the first year. The initial investment (R$ 206,065; USD 88,592) would have been paid off in 5 years considering only personnel savings. Other findings included significant reductions of audit adjustments to patient hospital bills and urgent requests and returns of medications to the central pharmacy. CONCLUSIONS: Evidence of the positive impact of this technology on personnel time and costs and on other outcomes of interest is important for decision making by health managers.
引用
收藏
页码:629 / 636
页数:8
相关论文
共 50 条
  • [1] Drug-dispensing errors in the hospital pharmacy
    Anacleto, Tania Azevedo
    Perini, Edson
    Rosa, Mario Borges
    Cesar, Cibele Comini
    CLINICS, 2007, 62 (03) : 243 - 250
  • [2] Evaluation of Drug-Dispensing Errors at the Internal Medicine of an University Hospital
    Bonifacio Neto, Amador A.
    de Matos, Vanessa T. G.
    Toffoli Kadri, Monica C.
    LATIN AMERICAN JOURNAL OF PHARMACY, 2013, 32 (01): : 26 - 30
  • [3] WORK ANALYSIS OF DRUG-DISPENSING PROCESS IN A HOSPITAL EMERGENCY PHARMACY
    Rosso, Caroline Brum
    Vieira, Leticia Canal
    Couto da Silva, Sabrina Leticia
    Amaral, Fernando Goncalves
    INDEPENDENT JOURNAL OF MANAGEMENT & PRODUCTION, 2016, 7 (01): : 134 - 150
  • [4] Impact of automated medication dispensing system in a hospital pharmacy
    Badrane, Laura
    Arnoux, Laeticia
    Fizesan, Marie
    Boin, Christopher
    Aujoulat, Olivier
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACY, 2018, 40 (01) : 298 - 298
  • [5] Impact of automated drug dispensing system on patient safety
    Alanazi, Majed Falah
    Shahein, Majed Ibrahim
    Alsharif, Hamad Mohammed
    Alotaibi, Saif Mohammed
    Alanazi, Abdulsalam Owaidh
    Alanazi, Ahmed Obaidallah
    Alharbe, Umar Abdolah
    Almfalh, Hanad S. S.
    Amirthalingam, Palanisamy
    Hamdan, Ahmed Mohsen
    Veeramani, Vinoth Prabhu
    Mohamed, Shahul Hameed Pakkir
    Ali, Mostafa A. Sayed
    PHARMACY PRACTICE-GRANADA, 2022, 20 (04):
  • [6] DRUG-DISPENSING ERRORS - ONE MORE CASE
    CATELLIER, CR
    OLIVIER, G
    SAUCIER, G
    NADEAU, A
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1992, 146 (09) : 1525 - 1526
  • [7] Clomipramine, clomiphene, and generic drug-dispensing errors
    Bavle, Amar
    Andrade, Chittaranjan
    INDIAN JOURNAL OF PSYCHIATRY, 2016, 58 (03) : 347 - U133
  • [8] RECURRENT HYPOGLYCEMIA SECONDARY TO DRUG-DISPENSING ERROR
    SHUMAK, SL
    CORENBLUM, B
    STEINER, G
    ARCHIVES OF INTERNAL MEDICINE, 1991, 151 (09) : 1877 - 1878
  • [9] Evaluating the impact of an automated drug retrieval cabinet and robotic dispensing system in a large hospital central pharmacy
    Lin, Alex C.
    Gamble, Justin M.
    Gabriel, Mina K.
    Hong, Tzu-Yen
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2024, 82 (01) : 32 - 43
  • [10] Adherence to medication before and after the use of a Drug-Dispensing System with usage control
    Vieira, Liliana Batista
    Ueta, Julieta
    Leira Pereira, Leonardo Regis
    BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2015, 51 (02) : 329 - 337