Assessing soil CO2 efflux using continuous measurements of CO2 profiles in soils with small solid-state sensors

被引:255
|
作者
Tang, JW [1 ]
Baldocchi, DD [1 ]
Qi, Y [1 ]
Xu, LK [1 ]
机构
[1] Univ Calif Berkeley, Dept Environm Sci Policy & Management, Berkeley, CA 94720 USA
关键词
CO2; profile; efflux; soil respiration; diffusion; sensor; soil CO2 concentration;
D O I
10.1016/S0168-1923(03)00112-6
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
This paper describes a new method to monitor continuously soil CO2 profiles using small solid-state CO2 sensors buried at different depths of the soil. Based on the measurement of soil CO2 profile and a gaseous diffusivity model, we estimated soil CO2 efflux, which was mainly from heterotrophic respiration, and its temporal variation in a dry season in a Mediterranean savanna ecosystem in California. The daily mean values of CO2 concentrations in soils had small variation, but the diurnal variation was significant and correlated well with soil temperature. The daily mean CO2 concentration remained steady at 396 mumol mol(-1) at 2 cm depth during the dry summer from days 200 to 235 in 2002. Over the same period, CO2 concentration decreased from 721 to 611 mumol mol(-1) at 8 cm depth, and from 1044 to 871 mumol mol(-1) at 16 cm. The vertical soil CO2 concentrations changed almost linearly with depth up to 16 cm, but the gradient varied over time. Based on the soil CO2 gradient and the diffusion coefficient estimated from the Millington-Quirk model, continuous soil CO2 efflux was calculated. The daily mean values of CO2 efflux slightly decreased from 0.43 to 0.33 mumol m(-2) s(-1) with a mean of 0.37 mumol m(-2) s(-1). The mean diurnal range of CO2 efflux was greater than the range of daily mean CO2 efflux within the study period. The diurnal variation of soil CO2 efflux ranged from 0.32 to 0.45 mumol m(-2) s(-1) with the peak value reached between 14:30 and 16:30 h. This pattern corresponded well with the increase in soil temperatures during this time. By plotting CO2 efflux vs. soil temperature, we found that CO2 efflux correlated exponentially with soil temperature at the depth of 8 cm, with R-2 of 0.86 and Q(10) of 1.27 in the summer dry season. The Q(10) value increased with the depth of soil temperature measurements. The high correlation between CO2 efflux and temperature explains the diurnal pattern of CO2 efflux, but moisture may become another factor driving the seasonal pattern when moisture changes over seasons. The estimated CO2 efflux using this method was very close to chamber measurements, suggesting that this method can be used for long-term continuous measurements of soil CO2 efflux. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:207 / 220
页数:14
相关论文
共 50 条
  • [1] Performance of Solid-State Sensors for Continuous, Real-Time Measurement of Soil CO2 Concentrations
    Young, Stephen L.
    Pierce, Francis J.
    Streubel, Jason D.
    Collins, Harold P.
    AGRONOMY JOURNAL, 2009, 101 (06) : 1417 - 1420
  • [2] Using measurements of soil CO2 efflux and concentrations to infer the depth distribution of CO2 production in a forest soil
    Drewitt, GB
    Black, TA
    Jassal, RS
    CANADIAN JOURNAL OF SOIL SCIENCE, 2005, 85 (02) : 213 - 221
  • [3] CO2 MONITORING BY SOLID-STATE LIMITING-CURRENT SENSORS
    NARDUCCI, D
    FACHERIS, L
    MARI, CM
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 25 (1-3) : 636 - 638
  • [4] Features of behavior of solid-state CO2 sensors at low temperatures
    Leonova, L
    Dobrovolsky, Y
    Vinokurov, A
    Treglazov, I
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2003, 7 (02) : 87 - 90
  • [5] Features of behavior of solid-state CO2 sensors at low temperatures
    L. Leonova
    Y. Dobrovolsky
    A. Vinokurov
    I. Treglazov
    Journal of Solid State Electrochemistry, 2003, 7 : 87 - 90
  • [6] SOLID-STATE POTENTIOMETRIC CO2 SENSORS USING ANION CONDUCTOR AND METAL CARBONATE
    MIURA, N
    YAN, YT
    SATO, M
    YAO, S
    NONAKA, S
    SHIMIZU, Y
    YAMAZOE, N
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) : 260 - 265
  • [7] Solid-state polymerization of polycarbonates using supercritical CO2
    Venable and Kenan Laboratories, Department of Chemistry, Univ. of N. Carolina at Chapel Hill, Chapel Hill, NC 27599, United States
    不详
    不详
    Macromolecules, 9 (3167-3169):
  • [8] Solid-state polymerization of polycarbonates using supercritical CO2
    Gross, SM
    Flowers, D
    Roberts, G
    Kiserow, DJ
    DeSimone, JM
    MACROMOLECULES, 1999, 32 (09) : 3167 - 3169
  • [9] BETA''-ALUMINA SOLID ELECTROLYTES FOR SOLID-STATE ELECTROCHEMICAL CO2 GAS SENSORS
    JUN, L
    WEPPNER, W
    SOLID STATE COMMUNICATIONS, 1990, 76 (03) : 311 - 313
  • [10] Miniaturized solid state electrochemical CO2 sensors
    Steudel, E
    Birke, P
    Weppner, W
    ELECTROCHIMICA ACTA, 1997, 42 (20-22) : 3147 - 3153