Comparative evaluation of 2.0 mm locking plate system vs 2.0 mm non-locking plate system for mandibular angle fracture fixation: a prospective randomized study

被引:0
|
作者
Yang, L. [1 ]
Patil, P. M. [2 ]
机构
[1] Lanzhou Univ, Hosp 2, Dept Stomatol, Lanzhou 730000, Gansu, Peoples R China
[2] Sharda Univ, Sch Dent Sci, Dept Oral & Maxillofacial Surg, Greater Noida, Uttar Pradesh, India
关键词
Mandibular angle fractures; Locking plate system; Non-locking plate system; Erich arch bar fixation; Intermaxillary fixation; Occlusal derangment; BONE;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
OBJECTIVE: This prospective randomized study evaluated the efficacy of a 2.0 mm locking plate/screw system compared with a 2.0-mm nonlocking plate/screw system in fixation of 60 isolated non-comminuted mandibular angle fractures. PATIENTS AND METHODS: Sixty patients were randomly assigned to receive a 2.0 mm locking plate (group A, n = 30) or 2.0 mm nonlocking plate (group B, n = 30). All patients were followed up to 6 months postoperatively and evaluated for complications, occlusal stability and overall results of fixation. RESULTS: Five complications occurred in the locking group and fourteen in the non-locking group with complication rates equalling 17% and 47% respectively. When comparing the overall results according to plates used, the chi(2) test showed a statistically significant difference between the locking and non-locking plates (p < 0.01). Fewer patients required IMF in group A. CONCLUSIONS: Mandibular angle fractures treated with 2.0 mm locking plates show greater stability and were associated with fewer complications than with 2.0 mm non-locking plates.
引用
收藏
页码:552 / 556
页数:5
相关论文
共 50 条
  • [1] Comparative evaluation of 2.0-mm locking plate system vs 2.0-mm nonlocking plate system for mandibular fracture: a prospective randomized study
    Singh, V.
    Kumar, I.
    Bhagol, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 40 (04) : 372 - 377
  • [2] Comparative evaluation of 2.3 mm locking plate system vs conventional 2.0 mm non locking plate system for mandibular condyle fracture fixation: a seven year retrospective study
    Zhang, J.
    Wang, X.
    Wu, R. -H.
    Zhuang, Q. -W.
    Gu, Q. P.
    Meng, J.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2015, 19 (05) : 712 - 718
  • [3] Comparative evaluation of 2.0-mm locking plate system vs. 2.0-mm nonlocking plate system for mandibular fractures - a retrospective study
    Kumar I.
    Singh V.
    Singh A.
    Arora V.
    Bajaj A.
    Oral and Maxillofacial Surgery, 2013, 17 (4) : 287 - 291
  • [4] Use of a 2.0-mm locking plate/screw system for mandibular fracture surgery
    Ellis, E
    Graham, J
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 60 (06) : 642 - 645
  • [5] Clinical aspects of a 2.0-mm locking plate system for mandibular fracture surgery
    Sauerbier, Sebastian
    Kuenz, Jana
    Hauptmann, Silke
    Hoogendijk, Christiaan Frederik
    Liebehenschel, Niels
    Schoen, Ralf
    Schmelzeisen, Rainer
    Gutwald, Ralf
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2010, 38 (07) : 501 - 504
  • [6] Use of a 2.0-mm locking plate/screw system for mandibular fracture surgery - Discussion
    Foley, WL
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 60 (06) : 645 - 646
  • [7] A comparative study evaluating the efficacy of 2.0-mm mini locking plate and 2.0-mm three-dimensional locking miniplates in mandibular angle fractures
    Subramaniyan, Deepika
    Sathyanarayanan, R.
    Suresh, V
    Subramaniyan, Monica
    Venugopalan
    Guna, Thamizhp Pozhil
    FORMOSAN JOURNAL OF SURGERY, 2021, 54 (02) : 61 - 65
  • [8] A Meta-analysis Comparing the 2.0-mm Locking Plate System With the 2.0-mm Nonlocking Plate System in Treatment of Mandible Fractures
    Zhan, Shilong
    Jiang, Yinhua
    Cheng, Zhe
    Ye, Jianqing
    JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (06) : 2094 - 2097
  • [9] Study of Efficacy and the Comparison Between 2.0 mm Locking Plating System and 2.0 mm Standard Plating System in Mandibular Fractures
    Kumar B.P.
    Kumar K.A.J.
    Venkatesh V.
    Mohan A.P.
    Ramesh K.
    Mallikarjun K.
    Journal of Maxillofacial and Oral Surgery, 2015, 14 (3) : 799 - 807
  • [10] Comparative in vitro mechanical evaluation of techniques using a 2.0 mm locking fixation system for simulated fractures of the mandibular body
    de Medeiros, Raquel Correia
    de Moura, Andrezza Lauria
    Sawazaki, Renato
    Fernandes Moreira, Roger William
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (03) : 302 - 305