701.2 Magnetism: Basic Concepts and Phenomena - 704 Electric Components and Equipment - 706.1.1 Electric Power Transmission - 731.1 Control Systems - 731.3 Specific Variables Control - 914.1 Accidents and Accident Prevention - 932.3 Plasma Physics;
D O I:
10.1049/el.2017.1007
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
To achieve the maximum current rising rate, second-generation Experimental Advanced Superconducting Tokamak (EAST) plasma vertical displacement active feedback power supply applies voltage control mode while retaining the first-generation current tracking mode. When the power supply outputs high voltage, the accompanied frequent over-current protection will return the power to DC side, which leads to over-voltage protection, so the current limiting protection is applied. Experimental results prove that the voltage mode can greatly improve the ability to suppress vertical unstable displacement of plasma.
机构:
School of Electrical Engineering and Automation,Hefei University of TechnologySchool of Electrical Engineering and Automation,Hefei University of Technology
黄海宏
论文数: 引用数:
h-index:
机构:
晏腾
王海欣
论文数: 0引用数: 0
h-index: 0
机构:
School of Electrical Engineering and Automation,Hefei University of TechnologySchool of Electrical Engineering and Automation,Hefei University of Technology