Exergetic optimization of absorption chillers - A case study

被引:6
|
作者
Szabo, Gabor L. [1 ]
机构
[1] Univ Debrecen, Dept Bldg Serv & Bldg Engn, Otemeto Str 2-4, H-4028 Debrecen, Hungary
关键词
Absorption chiller; Exergetic optimization; Quantitative and qualitative indicators; INDUSTRIAL-WASTE HEAT; MULTIOBJECTIVE OPTIMIZATION; TEMPERATURE; BUILDINGS; ENERGY; SYSTEM;
D O I
10.1016/j.csite.2021.101634
中图分类号
O414.1 [热力学];
学科分类号
摘要
The best way to meet the European Union's energy awareness goals is to use a heat pump/refrigerator that requires renewable energy or waste heat to operate. Absorption machines are often powered by renewable energy or waste heat. This article, it was examined how absorption chillers can be optimized for cooling. This requires increasing the minima of the cooling exergy efficiency of absorption chillers. The effects of this increase on the quantitative and qualitative indicators were also examined. For this purpose, these indicators are described using secondary indicators instead of the basic data. This can simplify the identification of intervention points to increase the qualitative and quantitative indicators. Taking these effects into account, it was concluded that the three best choices for creating a cooling optimization are to change either the generator temperature only, the generator and condensation temperatures, the condensation temperatures only respectively. This article, it is introduced new qualitative indicators. Due could help better characterization of absorption chillers and can form the basis for further developments.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Installing absorption chillers
    Crowther, H
    ASHRAE JOURNAL, 2000, 42 (07) : 41 - 42
  • [2] Optimizing absorption chillers
    Consulting-Specifying Engineer, 1999, 25 (01):
  • [3] MULTIEFFECT ABSORPTION CHILLERS
    ZIEGLER, F
    KAHN, R
    SUMMERER, F
    ALEFELD, G
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1993, 16 (05): : 301 - 311
  • [4] Optimization of energy plants including water/lithium bromide absorption chillers
    Bruno, JC
    Miquel, J
    Castells, F
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2000, 24 (08) : 695 - 717
  • [5] PURGE NEEDS IN ABSORPTION CHILLERS
    MURRAY, JG
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1993, 35 (10): : 40 - &
  • [6] Purge needs in absorption chillers
    Murray, J.G.
    ASHRAE Journal, 1993, 35 (10)
  • [7] SAVE ENERGY WITH ABSORPTION CHILLERS
    DOTIWALLA, KK
    HYDROCARBON PROCESSING, 1992, 71 (02): : 112 - 113
  • [8] Design challenges in absorption chillers
    Herold, KE
    MECHANICAL ENGINEERING, 1995, 117 (10) : 80 - 83
  • [9] Research on systematic analysis and optimization method for chillers based on model predictive control: A case study
    Deng, Jiewen
    Qiang, Wenbo
    Peng, Chenwei
    Wei, Qingpeng
    Zhang, Hui
    ENERGY AND BUILDINGS, 2023, 285
  • [10] Performance improvement of absorption chillers by means of additives - A numerical study
    Olbricht, Michael
    Lonardi, Federico
    Luke, Andrea
    SOLAR ENERGY, 2018, 166 : 138 - 145