Conductometric analysis in bio-applications: A universal impedance spectroscopy-based approach using modified electrodes

被引:12
|
作者
Canali, Chiara [1 ]
Larsen, Layla Bashir [1 ]
Martinsen, Orjan Grottem [2 ,3 ]
Heiskanen, Arto [1 ]
机构
[1] Tech Univ Denmark, Dept Micro & Nanotechnol, DK-2800 Lyngby, Denmark
[2] Univ Oslo, Dept Phys, N-0371 Oslo, Norway
[3] Oslo Univ Hosp, Dept Biomed & Clin Engn, N-0372 Oslo, Norway
来源
关键词
Electrochemical impedance spectroscopy; Universal protocol for impedance based conductivity determination; Customised Matlab-based algorithm for automated spectral analysis; Protein repellent electrode modification; Conductivity measurements in cell culture medium; BACTERIAL METABOLISM; CELL-PROLIFERATION; REAL-TIME; CONDUCTIVITY; MICROBIOLOGY; SCAFFOLDS; SENSOR; CHIP;
D O I
10.1016/j.snb.2015.02.029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a universal protocol for quick and reproducible conductivity determinations in bioapplications using electrochemical impedance spectroscopy (EIS), electrode modification and automated spectral analysis. Two-terminal EIS measurements may be acquired using any standard impedance analyser adjusting the applied sinusoidal potential and frequency range for spectral analysis. An implemented Matlab algorithm displays the acquired spectra, automatically identifies the frequency at which the phase angle (phi) is closest to 0 degrees and determines the impedance magnitude, i.e. the solution resistance (R-S). The corresponding conductivity value is immediately calculated as the ratio of the conductivity cell constant (kappa), determined based on calibration, and R-S. This protocol eliminates the need for evaluating a specific equivalent circuit followed by non-linear regression based curve fitting that is generally required in EIS-based conductivity determinations. The protocol is applicable to conductivity determinations using different conductivity cell configurations in any electrolyte solution regardless of its composition, i.e. in solutions with or without electroactive species that give rise to faradaic interface impedance. Conducted measurements showed high reproducibility in good agreement with a commercial conductometer in a wide range of ionic strengths up to five times that of physiological PBS. Since measurements in cell culture medium with bare gold electrodes indicated the need for recalibration to counteract the effect of biomolecule physisorption, the validity of the protocol was further extended using a protein-repellent coating of poly(ethylene glycol) methyl ether thiol self-assembled monolayer. This effectively eliminated electrode fouling, facilitating high reproducibility in repeated conductivity determinations in the presence of proteins. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:544 / 550
页数:7
相关论文
共 50 条
  • [1] Understanding of the dynamics of water molecules by using terahertz spectroscopy and its bio-applications
    Ogawa, Yuichi
    FOURTH INTERNATIONAL SEMINAR ON PHOTONICS, OPTICS, AND ITS APPLICATIONS (ISPHOA 2020), 2021, 11789
  • [2] Preparing MIM Feedstocks for Bio-applications using an Agar-based Binder
    Barreiros, F. M.
    Martins, A. G.
    Matos, M.
    Mascarenhas, J.
    Vieira, M. T.
    ADVANCED MATERIALS FORUM IV, 2008, 587-588 : 385 - +
  • [3] Impedance spectroscopy for monosaccharides detection using responsive hydrogel modified paper-based electrodes
    Daikuzono, C. M.
    Delaney, C.
    Tesfay, H.
    Florea, L.
    Oliveira, O. N., Jr.
    Morrin, A.
    Diamond, D.
    ANALYST, 2017, 142 (07) : 1133 - 1139
  • [4] Detection and Discrimination Modeling of Cells in Droplet Using Impedance Spectroscopy-Based Microfluidic System
    Chowdhury, Shabbir
    Hussain, Mohammad Asif
    Sobahi, Nebras
    INTERNATIONAL TRANSACTION JOURNAL OF ENGINEERING MANAGEMENT & APPLIED SCIENCES & TECHNOLOGIES, 2022, 13 (03):
  • [5] Modified PCA and PLS: Towards a better classification in Raman spectroscopy-based biological applications
    Guo, Shuxia
    Roesch, Petra
    Popp, Juergen
    Bocklitz, Thomas
    JOURNAL OF CHEMOMETRICS, 2020, 34 (04)
  • [6] Sensors using AlGaN/GaN based high electron mobility transistor for environmental and bio-applications
    Ren, Fan
    Pearton, Stephen J.
    PHYSICA STATUS SOLIDI C: CURRENT TOPICS IN SOLID STATE PHYSICS, VOL 9, NO 2, 2012, 9 (02): : 393 - 398
  • [7] Electrical detection and characterization of bacterial adhesion using electrochemical impedance spectroscopy-based flow chamber
    Bayoudh, Sonia
    Othmane, Ali
    Ponsonnet, Laurence
    Ben Ouada, Hafedh
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2008, 318 (1-3) : 291 - 300
  • [8] Development of a portable electrochemical sensing platform for impedance spectroscopy-based biosensing using an ARM-based microcontroller
    Spiro, Joseph Charles Khavul
    Mishra, Kundan Kumar
    Dhamu, Vikram Narayanan
    Bhatia, Avi
    Muthukumar, Sriram
    Prasad, Shalini
    SENSORS & DIAGNOSTICS, 2024, 3 (11):
  • [9] Bio-Recognition in Spectroscopy-Based Biosensors for *Heavy Metals-Water and Waterborne Contamination Analysis
    Aloisi, Alessandra
    Della Torre, Antonio
    De Benedetto, Angelantonio
    Rinaldi, Rosaria
    BIOSENSORS-BASEL, 2019, 9 (03):
  • [10] Electrochemical Impedance Spectroscopy-Based Microfluidic Biosensor Using Cell-Imprinted Polymers for Bacteria Detection
    Akhtarian, Shiva
    Brar, Satinder Kaur
    Rezai, Pouya
    BIOSENSORS-BASEL, 2024, 14 (09):