Automated Whole-Body Bone Lesion Detection for Multiple Myeloma on 68Ga-Pentixafor PET/CT Imaging Using Deep Learning Methods

被引:80
|
作者
Xu, Lina [1 ,2 ]
Tetteh, Giles [1 ,3 ]
Lipkova, Jana [1 ,3 ]
Zhao, Yu [1 ,3 ]
Li, Hongwei [1 ,3 ]
Christ, Patrick [1 ,3 ]
Piraud, Marie [1 ,3 ]
Buck, Andreas [4 ]
Shi, Kuangyu [2 ]
Menze, Bjoern H. [1 ,3 ]
机构
[1] Tech Univ Munich, Dept Informat, Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Dept Nucl Med, Munich, Germany
[3] Tech Univ Munich, Inst Med Engn, Munich, Germany
[4] Univ Wurzburg, Dept Nucl Med, Wurzburg, Germany
关键词
COMPUTER-ASSISTED DIAGNOSIS; CONSENSUS STATEMENT; F-18-FDG PET/CT; NEURAL-NETWORKS; AIDED DETECTION; TUMOR SIZE; CT; SEGMENTATION; MRI; QUANTIFICATION;
D O I
10.1155/2018/2391925
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The identification of bone lesions is crucial in the diagnostic assessment of multiple myeloma (MM). Ga-68-Pentixafbr PET/Cr can capture the abnormal molecular expression of CXCR-4 in addition to anatomical changes. However, whole-body detection of dozens of lesions on hybrid imaging is tedious and error prone. It is even more difficult to identify lesions with a large heterogeneity. This study employed deep learning methods to automatically combine characteristics of PET and CT for whole-body MM bone lesion detection in a 3D manner. Two convolutional neural networks (CNNs), V-Net and W-Net, were adopted to segment and detect the lesions. The feasibility of deep learning for lesion detection on Ga-68-Pentixafor PET/CT was first verified on digital phantoms generated using realistic PET simulation methods. Then the proposed methods were evaluated on real Ga-68-Pentixafor PET/CT scans of MM patients. The preliminary results showed that deep learning method can leverage multimodal information for spatial feature representation, and W-Net obtained the best result for segmentation and lesion detection. It also outperformed traditional machine learning methods such as random forest classifier (RF), k-Nearest Neighbors (k-NN), and support vector machine (SVM). The proof-of-concept study encourages further development of deep learning approach for MM lesion detection in population study.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] W-Net for Whole-Body Bone Lesion Detection on 68Ga-Pentixafor PET/CT Imaging of Multiple Myeloma Patients
    Xu, Lina
    Tetteh, Giles
    Mustafa, Mona
    Lipkova, Jana
    Zhao, Yu
    Bieth, Marie
    Christ, Patrick
    Piraud, Marie
    Menze, Bjoern
    Shi, Kuangyu
    MOLECULAR IMAGING, RECONSTRUCTION AND ANALYSIS OF MOVING BODY ORGANS, AND STROKE IMAGING AND TREATMENT, 2017, 10555 : 23 - 30
  • [2] Multiple Myeloma Presenting as a Superscan on 68Ga-Pentixafor PET/CT
    Pan, Qingqing
    Luo, Yaping
    Cao, Xinxin
    Ma, Yanru
    Li, Fang
    CLINICAL NUCLEAR MEDICINE, 2018, 43 (06) : 462 - 463
  • [3] 68Ga-pentixather PET/CT for newly diagnosed multiple myeloma: Comparison to 68Ga-pentixafor PET/CT
    Yang, Qiao
    Zhang, Fujing
    Hao, Zhixin
    Zhuang, Junling
    Huo, Li
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [4] Pulmonary Cryptococcosis Accidentally Detected by 68Ga-Pentixafor PET/CT in a Patient With Multiple Myeloma
    Pan, Qingqing
    Luo, Yaping
    Cao, Xinxin
    Li, Jian
    Li, Fang
    CLINICAL NUCLEAR MEDICINE, 2020, 45 (05) : 423 - 425
  • [5] Whole-body lesion detection and prostate cancer staging in 68Ga-PSMA-11 PET/CT using deep learning
    Capobianco, N.
    Gafita, A.
    Platsch, G.
    Sibille, L.
    Spottiswoode, B.
    Eiber, M.
    Weber, W. A.
    Navab, N.
    Nekolla, S. G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S273 - S274
  • [6] Brain Nocardiosis Mimicking Intracerebral Invasion on 68Ga-Pentixafor PET/CT in a Patient With Multiple Myeloma
    Zhao, Xiujuan
    Dai, Meng
    Li, Nuo
    Zhang, Jingmian
    Zhao, Xinming
    CLINICAL NUCLEAR MEDICINE, 2024, 49 (09) : e459 - e461
  • [7] 68Ga-Pentixafor PET/CT May Fail to Detect Recurrent Multiple Myeloma with Extramedullary Disease
    Pan, Qingqing
    Luo, Yaping
    Cao, Xinxin
    Li, Jian
    Li, Fang
    DIAGNOSTICS, 2023, 13 (05)
  • [8] A prospective comparison of 68Ga-Pentixafor PET/CT and 18F-FDG PET/CT for the detection of intramedullary and extramedullary lesions in multiple myeloma
    Tang, S.
    Wang, Y.
    Tian, Y.
    Li, C.
    Xiao, Z.
    Chen, J.
    He, Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S45 - S45
  • [9] Evaluation of Chemokine Receptor-4 Expression by 68Ga-Pentixafor PET/CT in Patients with Multiple Myeloma
    Ozkan, Elgin
    Soydal, Cigdem
    Sahin, Ugur
    Beksac, Meral
    Ozturk, Cemaleddin
    Bozdag, Sinem Civriz
    Topcuoglu, Pervin
    Kropf, Saskia
    Wester, Hans-Juergen
    Kucuk, Ozlem Nuriye
    UHOD-ULUSLARARASI HEMATOLOJI-ONKOLOJI DERGISI, 2019, 29 (04): : 210 - 218
  • [10] Imaging CXCR4 receptors expression for staging multiple myeloma by using 68Ga-Pentixafor PET/CT: comparison with 18F-FDG PET/CT
    Shekhawat, Amit Singh
    Singh, Baljinder
    Malhotra, Pankaj
    Watts, Ankit
    Basher, Rajender
    Kaur, Harneet
    Hooda, Monika
    Radotra, Bishan D.
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1136):