DQ transformation development for single-phase systems to compensate harmonic distortion and reactive power

被引:61
|
作者
González, M [1 ]
Cárdenas, V [1 ]
Pazos, F [1 ]
机构
[1] Univ Autonoma San Luis Potosi, Fac Ingn, Ctr Invest & Estudios Posgrado, Mexico City 78290, DF, Mexico
关键词
D O I
10.1109/CIEP.2004.1437575
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An extension of the DQ Transformation for single-phase systems is presented in this work, since the original approach can only be applied to three-phase systems. The theoretical principle of the proposed transformation is presented. Equations about how the fundamental component and the harmonics of the variable of concern are mapped in the dq reference frame are. derived. The proposed transformation is evaluated under ideal and real conditions, and with magnitude and/or phase deviations. Besides, an adequate selection of the reference generator scheme to compensate systems with harmonic distortion and reactive power is made, obtaining an optimal selection of all parameters.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 50 条
  • [1] Harmonic distortion and reactive power compensation in single phase power systems using orthogonal transformation technique
    Hosny, W.
    Dobrucky, B.
    2007 42ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2007, : 629 - 633
  • [2] Reactive Power Compensation and Distortion Power Variation Identification in Extended Budeanu Power Theory for Single-Phase Systems
    Soljan, Zbigniew
    Zajkowski, Maciej
    Borusiewicz, Andrzej
    de la Rosa, Juan-Jose Gonzalez
    Florencias-Oliveros, Olivia
    Sulis, Sara
    ENERGIES, 2024, 17 (01)
  • [3] Harmonic Distortion by Single-Phase Photovoltaic Inverter
    Stoyanov, Ivaylo
    Iliev, Teodor
    Evstatiev, Boris
    Mihaylov, Grigor
    2019 11TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE), 2019,
  • [4] Single-phase active power filter for reactive power and harmonic compensation.
    Cortés, L
    Horta, S
    Claudio, A
    Cárdenas, VM
    CIEP'98: VI IEEE INTERNATIONAL POWER ELECTRONICS CONGRESS, TECHNICAL PROCEEDINGS, 1998, : 184 - 187
  • [5] A SINGLE-PHASE UPS SYSTEM WITH HARMONIC SUPPRESSION AND REACTIVE POWER COMPENSATION
    Oliveira da Silva, Sergio A.
    Modesto, Rodrigo A.
    Feracin Neto, Angelo
    de Souza Cervantes, Silvia G.
    2009 BRAZILIAN POWER ELECTRONICS CONFERENCE, VOLS 1 AND 2, 2009, : 153 - +
  • [6] The Transformerless Single-Phase Universal Active Power Filter for Harmonic and Reactive Power Compensation
    Nogueira Santos, Welflen Ricardo
    Cabral da Silva, Edison Roberto
    Jacobina, Cursino Brandao
    Fernandes, Eisenhawer de Moura
    Oliveira, Alexandre Cunha
    Matias, Rafael Rocha
    Guedes Filho, Dalton Franca
    Almeida, Otacilio M.
    Santos, Patryckson Marinho
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (07) : 3563 - 3572
  • [7] Single-phase Grid Integrated Photovoltaic Inverter for Harmonic and Reactive Power Compensation
    Behera, Maheswar Prasad
    Ray, Pravat Kumar
    2015 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2015,
  • [8] A repetitive based controller for a shunt active filter to compensate for reactive power and harmonic distortion
    Escobar, G.
    Ortega, R.
    Astolfi, A.
    Martinez, M. F.
    Leyva-Ramos, J.
    2005 44th IEEE Conference on Decision and Control & European Control Conference, Vols 1-8, 2005, : 6480 - 6485
  • [9] Investigation on a Methodology to Detect Instantaneous Reactive and Harmonic Currents in Single-phase Systems
    Li, Qingquan
    Wang, Wei
    Qin, Liwei
    Zou, Liang
    Li, Qingmin
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 3887 - +
  • [10] The Comparison Study of Harmonic Detection Algorithms for Single-Phase Power Systems
    Padungsin, Maneerat
    Narongrit, Tosaporn
    Areerak, Kongpol
    2018 5TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS), 2018,