Determination of fission products in nuclear samples by capillary electrophoresis-inductively coupled plasma mass spectrometry (CE-ICP-MS)

被引:40
|
作者
Pitois, Aurelien [1 ]
de las Heras, Laura Aldave [1 ]
Betti, Maria [1 ]
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Transuranium Elements, D-76125 Karlsruhe, Germany
关键词
capillary electrophoresis; inductively coupled plasma mass spectrometry; fission products; caesium; lanthanide;
D O I
10.1016/j.ijms.2007.11.012
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Determination of fission products and of their isotopic composition is of high importance for the characterisation and complete inventory of nuclear fuels. Radiometric and mass spectrometric methods, which are currently used, enable only an incomplete determination of the fission products. Radiometric methods cannot be applied to all fission products and mass spectrometric methods are hindered by the existence of isobaric interferences, therefore a previous chemical separation is required before mass spectrometric analysis. Capillary electrophoresis (CE) has been coupled with inductively coupled plasma mass spectrometry (both ICP-QMS and ICP-SFMS). Typical detection limits of 6 ng/mL and 4 pg/mL for caesium as well as 8 ng/mL and 7 pg/mL for lanthanides have been obtained by CE-ICP-QMS and CE-ICP-SFMS, respectively. In addition to these very low detection limits, the procedures present the advantages to be fast (6 min for caesium and 13 min for lanthanides, respectively), to require a low microliter range sample volume and a nanoliter range injection volume. The radiation dose for the personnel as well as the volume of nuclear liquid wastes generated during the measurements are consequently reduced. The procedures have been applied to nuclear samples from PUREX process and leachates from MOX fuels. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:118 / 126
页数:9
相关论文
共 50 条
  • [1] Determination of metal glycinate in premixes using capillary electrophoresis coupled with an inductively coupled plasma mass spectrometry detector (CE-ICP-MS).
    Ionescu, C.
    Vacchina, V.
    Oguey, S.
    Lobinski, R.
    Bravo, D.
    JOURNAL OF DAIRY SCIENCE, 2010, 93 : 828 - 829
  • [2] Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry (CE-ICP-MS) for Quantification of Iron Redox Species (Fe(II), Fe(III))
    Michalke, Bernhard
    Willkommen, Desiree
    Venkataramani, Vivek
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (159):
  • [3] Iron Redox Speciation Analysis Using Capillary Electrophoresis Coupled to Inductively Coupled Plasma Mass Spectrometry (CE-ICP-MS)
    Michalke, Bernhard
    Willkommen, Desiree
    Venkataramani, Vivek
    FRONTIERS IN CHEMISTRY, 2019, 7
  • [4] Determination of neodymium-fulvic acid binding constants by capillary electrophoresis inductively coupled plasma mass spectrometry (CE-ICP-MS)
    Sonke, JE
    Salters, VJM
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (02) : 235 - 240
  • [5] Investigation of a liposomal oxaliplatin drug formulation by capillary electrophoresis hyphenated to inductively coupled plasma mass spectrometry (CE-ICP-MS)
    Nguyen, Tam T. T. N.
    Ostergaard, Jesper
    Sturup, Stefan
    Gammelgaard, Bente
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (06) : 2131 - 2139
  • [6] Investigation of a liposomal oxaliplatin drug formulation by capillary electrophoresis hyphenated to inductively coupled plasma mass spectrometry (CE-ICP-MS)
    Tam T. T. N. Nguyen
    Jesper Østergaard
    Stefan Stürup
    Bente Gammelgaard
    Analytical and Bioanalytical Chemistry, 2012, 402 : 2131 - 2139
  • [7] Disequilibrium effects in metal speciation by capillary electrophoresis inductively coupled plasma mass spectrometry (CE-ICP-MS); theory, simulations and experiments
    Sonke, JE
    Salters, VJM
    ANALYST, 2004, 129 (08) : 731 - 738
  • [8] Speciation of mercury by capillary electrophoresis-inductively coupled plasma mass spectrometry
    Silva Da Rocha, M.
    Soldado, A.B.
    Blanco-González, E.
    Sanz-Medel, A.
    Biomedical Chromatography, 2000, 14 (01) : 6 - 7
  • [9] Roxarsone and transformation products in chicken manure: Determination by capillary electrophoresis-inductively coupled plasma-mass spectrometry
    Rosal, CG
    Momplaisir, GM
    Heithmar, EM
    ELECTROPHORESIS, 2005, 26 (7-8) : 1606 - 1614
  • [10] Determination of Arsenic Speciation in Scomberomorus Niphonius by Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry
    Chen Fa-rong
    Zheng Li
    Wang Zhi-guang
    Sun Jie
    Han Li-hui
    Wang Xiao-ru
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (06) : 1675 - 1678