Whole-Brain Myelin Imaging Using 3D Double-Echo Sliding Inversion Recovery Ultrashort Echo Time (DESIRE UTE) MRI

被引:41
|
作者
Ma, Ya-Jun [1 ]
Searleman, Adam C. [1 ]
Jang, Hyungseok [1 ]
Wong, Jonathan [1 ,3 ]
Chang, Eric Y. [1 ,3 ]
Corey-Bloom, Jody [2 ]
Bydder, Graeme M. [1 ]
Du, Jiang [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, 9452 Med Ctr Dr, La Jolla, CA 92037 USA
[2] Univ Calif San Diego, Dept Neurosci, 9452 Med Ctr Dr, La Jolla, CA 92037 USA
[3] VA San Diego Healthcare Syst, Serv Radiol, San Diego, CA USA
基金
美国国家卫生研究院;
关键词
MAGNETIC-RESONANCE; WHITE-MATTER; QUANTITATIVE MRI; T-1; WATER; SEQUENCES; SENSE;
D O I
10.1148/radiol.2019190911
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Signal contamination from long T2 water is a major challenge in direct imaging of myelin with MRI. Nulling of the unwanted long T2 signals can be achieved with an inversion recovery (IR) preparation pulse to null long T2 white matter within the brain. The remaining ultrashort T2 signal from myelin can be detected with an ultrashort echo time (UTE) sequence. Purpose: To develop patient-specific whole-brain myelin imaging with a three-dimensional double-echo sliding inversion recovery (DESIRE) UTE sequence. Materials and Methods: The DESIRE UTE sequence generates a series of IR images with different inversion times during a single scan.The optimal inversion time for nulling long T2 signal is determined by finding minimal signal on the second echo. Myelin images are generated by subtracting the second echo image from the first UTE image. To validate this method, a prospective study was performed in phantoms, cadaveric brain specimens, healthy volunteers, and patients with multiple sclerosis (MS). A total of 20 healthy volunteers (mean age, 40 years +/- 13 [standard deviation], 10 women) and 20 patients with MS (mean age, 58 years +/- 8;15 women) who underwent MRI between November 2017 and February 2019 were prospectively included. Analysis of variance was performed to evaluate the signal difference between MS lesions and normal-appearing white matter in patients with MS. Results: High signal intensity and corresponding T2* and T1 of the extracted myelin vesicles provided evidence for direct imaging of ultrashort-T2 myelin protons using the UTE sequence. Gadobenate dimeglumine phantoms with a wide range of T1 values were selectively suppressed with DESIRE UTE. In the ex vivo brain study of MS lesions, signal loss was observed in MS lesions and was conformed with histologic analysis. In the human study, there was a significant reduction in normalized signal intensity in MS lesions compared with that in normal-appearing white matter (0.19 +/- 0.10 vs 0.76 +/- 0.11, respectively; P < .001). Conclusion: The double-echo sliding inversion recovery ultrashort echo time sequence can generate whole-brain myelin images specifically with a clinical 3-T scanner. (C) RSNA, 2019
引用
收藏
页码:362 / 374
页数:13
相关论文
共 50 条
  • [1] Preliminary use of a double-echo pulse sequence with 3D ultrashort echo time in the MRI of bones and joints
    Ma, Liheng
    Meng, Quanfei
    Chen, Yingming
    Zhang, Zhaohui
    Sun, Haixing
    Deng, Demao
    [J]. EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (05) : 1471 - 1475
  • [2] Improved volumetric myelin imaging in human brain using 3D dual echo inversion recovery-prepared UTE with complex echo subtraction
    Tang, Hyungseok
    Wei, Zhao
    Wu, Mei
    Ma, Ya-Jun
    Chang, Eric Y.
    Corey-Bloom, Jody
    Du, Jiang
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (04) : 1168 - 1177
  • [3] Myelin Imaging in Human Brain Using a Short Repetition Time Adiabatic Inversion Recovery Prepared Ultrashort Echo Time (STAIR-UTE)MRI Sequence in Multiple Sclerosis
    Ma, Ya-Jun
    Jang, Hyungseok
    Wei, Zhao
    Cai, Zhenyu
    Xue, Yanping
    Lee, Roland R.
    Chang, Eric Y.
    Bydder, Graeme M.
    Corey-Bloom, Jody
    Du, Jiang
    [J]. RADIOLOGY, 2020, 297 (02) : 392 - 404
  • [4] Volumetric imaging of myelin in vivo using 3D inversion recovery-prepared ultrashort echo time cones magnetic resonance imaging
    Ma, Ya-Jun
    Searleman, Adam C.
    Jang, Hyungseok
    Fan, Shu-Juan
    Wong, Jonathan
    Xue, Yanping
    Cai, Zhenyu
    Chang, Eric Y.
    Corey-Bloom, Jody
    Du, Jiang
    [J]. NMR IN BIOMEDICINE, 2020, 33 (10)
  • [5] Short T2 imaging using a 3D double adiabatic inversion recovery prepared ultrashort echo time cones (3D DIR-UTE-Cones) sequence
    Ma, Ya-Jun
    Zhu, Yanchun
    Lu, Xing
    Carl, Michael
    Chang, Eric Y.
    Du, Jiang
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (05) : 2555 - 2563
  • [6] Longitudinal Imaging of Injured Spinal Cord Myelin and White Matter with 3D Ultrashort Echo Time Magnetization Transfer (UTE-MT) and Diffusion MRI
    Tang, Qingbo
    Ma, Yajun
    Cheng, Qun
    Wu, Yuanshan
    Chen, Junyuan
    Du, Jiang
    Lu, Pengzhe
    Chang, Eric Y.
    [J]. Journal of Imaging, 2024, 10 (09)
  • [7] T1 measurement of bound water in cortical bone using 3D adiabatic inversion recovery ultrashort echo time (3D IR-UTE) Cones imaging
    Guo, Tan
    Ma, Yajun
    Jerban, Saeed
    Jang, Hyungseok
    Zhao, Wei
    Chang, Eric Y.
    Chen, Min
    Bydder, Graeme M.
    Du, Jiang
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 634 - 645
  • [8] Water phase transition and signal nulling in 3D dual-echo adiabatic inversion-recovery UTE (IR-UTE) imaging of myelin
    Athertya, Jiyo S.
    Shin, Soo Hyun
    Malhi, Bhavsimran Singh
    Lo, James
    Sedaghat, Sam
    Jang, Hyungseok
    Ma, Yajun
    Du, Jiang
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2024,
  • [9] Imaging of the region of the osteochondral junction (OCJ) using a 3D adiabatic inversion recovery prepared ultrashort echo time cones (3D IR-UTE-cones) sequence at 3 T
    Ma, Ya-Jun
    Jerban, Saeed
    Carl, Michael
    Wan, Lidi
    Guo, Tan
    Jang, Hyungseok
    Bydder, Graeme M.
    Chang, Eric Y.
    Du, Jiang
    [J]. NMR IN BIOMEDICINE, 2019, 32 (05)
  • [10] Optimized 3D Ultrashort Echo Time Pulmonary MRI
    Johnson, Kevin M.
    Fain, Sean B.
    Schiebler, Mark L.
    Nagle, Scott
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (05) : 1241 - 1250