High-resolution 3D X-ray diffraction microscopy: 3D mapping of deformed metal microstructures

被引:9
|
作者
Kutsal, Mustafacan [1 ,2 ]
Poulsen, Henning Friis [1 ]
Winther, Grethe [3 ]
Sorensen, Henning Osholm [1 ,4 ]
Detlefs, Carsten [2 ]
机构
[1] Tech Univ Denmark, Dept Phys, DK-2800 Lyngby, Denmark
[2] European Synchrotron, F-38043 Grenoble, France
[3] Tech Univ Denmark, Dept Civil & Mech Engn, DK-2800 Lyngby, Denmark
[4] Xnovo Technol ApS, DK-4600 Koge, Denmark
基金
欧洲研究理事会; 欧盟地平线“2020”;
关键词
ray imaging; X-ray diffraction; 3DXRD; structural materials; INDIVIDUAL GRAINS; POLYCRYSTALLINE MATERIALS; ORIENTATION; RECOVERY; CRYSTALLOGRAPHY; RECONSTRUCTION; MULTISCALE; DYNAMICS; STRESSES;
D O I
10.1107/S1600576722007361
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Three-dimensional X-ray diffraction microscopy, 3DXRD, has become an established tool for orientation and strain mapping of bulk polycrystals. However, it is limited to a finite spatial resolution of similar to 1.5-3 mm. Presented here is a high-resolution modality of the technique, HR-3DXRD, for 3D mapping of submicrometre-sized crystallites or subgrains with high spatial and angular resolution. Specifically, the method is targeted to visualization of metal microstructures at industrially relevant degrees of plastic deformation. Exploiting intrinsic crystallographic properties of such microstructures, the high resolution is obtained by placing a high-resolution imaging detector in between the near-field and far-field regimes. This configuration enables 3D mapping of deformation microstructure by determining the centre of mass and volume of the subgrains and generating maps by tessellation. The setup is presented, together with a data analysis approach. Full-scale simulations are used to determine limitations and to demonstrate HR-3DXRD on realistic phantoms. Misalignments in the setup are shown to cause negligible shifts in the position and orientation of the subgrains. Decreasing the signal-to-noise ratio is observed to lead primarily to a loss in the number of determined diffraction spots. Simulations of an alpha-Fe sample deformed to a strain of epsilon M-v = 0.3 and comprising 828 subgrains show that, despite the high degree of local texture, 772 of the subgrains are retrieved with a spatial accuracy of 0.1 mu m and an orientation accuracy of 0.0005 degrees.
引用
收藏
页码:1125 / 1138
页数:14
相关论文
共 50 条
  • [1] High-resolution 3D grain orientation mapping by inclined scanning 3D X-ray diffraction microscopy
    Kim, Jaemyung
    Hayashi, Yujiro
    Yabashi, Makina
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2023, 56 : 1416 - 1425
  • [2] High resolution 3D x-ray diffraction microscopy
    Miao, JW
    Ishikawa, T
    Johnson, B
    Anderson, EH
    Lai, B
    Hodgson, KO
    [J]. PHYSICAL REVIEW LETTERS, 2002, 89 (08) : 088303/1 - 088303/4
  • [4] High Resolution 3D X-Ray Diffraction Microscopy (vol 89, 088303, 2002)
    Miao, Jianwei
    Ishikawa, Tetsuya
    Johnson, Bart
    Anderson, Erik H.
    Lai, Barry
    Hodgson, Keith O.
    [J]. PHYSICAL REVIEW LETTERS, 2013, 111 (02)
  • [5] SUBMICRON RESOLUTION 3D X-RAY STRUCTURAL MICROSCOPY
    Larson, B. C.
    [J]. ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2002, 58 : C33 - C33
  • [6] 3D mapping with high-resolution images
    Toutin, T
    Chénier, R
    Carbonneau, Y
    Alcaïde, N
    [J]. GEOINFORMATION FOR EUROPEAN-WIDE INTEGRATION, 2003, : 121 - 125
  • [7] High-resolution 3D mapping of loops
    Linda Koch
    [J]. Nature Reviews Genetics, 2015, 16 (2) : 68 - 68
  • [8] High-resolution 3D X-ray imaging of intracranial nitinol stents
    Rudolph M. Snoeren
    Michael Söderman
    Johannes N. Kroon
    Ruben B. Roijers
    Peter H. N. de With
    Drazenko Babic
    [J]. Neuroradiology, 2012, 54 : 155 - 162
  • [9] High-resolution 3D imaging of integrated circuits by X-ray ptychography
    Odstrcil, Michal
    Holler, Mirko
    Raabe, Jorg
    Guizar-Sicairos, Manuel
    [J]. IMAGE SENSING TECHNOLOGIES: MATERIALS, DEVICES, SYSTEMS, AND APPLICATIONS V, 2018, 10656
  • [10] High-resolution 3D X-ray imaging of intracranial nitinol stents
    Snoeren, Rudolph M.
    Soderman, Michael
    Kroon, Johannes N.
    Roijers, Ruben B.
    de With, Peter H. N.
    Babic, Drazenko