Development of An Instantaneous Blood Pressure measuring System at the Wrist Based on the Volume-Compensation Method

被引:0
|
作者
Gao, Shumei [1 ]
Song, Yilin [1 ]
Tanaka, Shinobu [2 ]
Yamakoshi, Ken-ichi [2 ]
机构
[1] Heilongjiang Univ, Sch Mech & Elect Engn, Harbin, Peoples R China
[2] Kanazawa Univ, Fac Engn, Kanazawa, Ishikawa 9201192, Japan
关键词
Blood pressure; Volume-compensation method; Non-invasively measurement; MEAN ARTERIAL-PRESSURE; HUMAN FINGER; OSCILLOMETRIC METHOD;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An instantaneous blood pressure measuring system at the wrist based on the volume-compensation method is developed, and the characteristics and accuracy of the system are evaluated. Results of measurement indicated that, the radial artery could be completely compressed using the local pressurizing cuff, and the cuff-pressure controller is suitable for BP measurement in human. Also, the comparative measurements between the present system and the invasive blood pressure measuring device (direct method) indicated that, the results obtained from the two methods are well correlated not only in rest condition, but also in a stressful condition. Therefore, the system is capable of non-invasively measuring instantaneous blood pressure at radial artery.
引用
收藏
页码:1199 / +
页数:2
相关论文
共 50 条
  • [41] Accuracy of the visomat handy wrist blood pressure measuring device according to the International Protocol
    Saladini, Francesca
    Benetti, Elisabetta
    Palatini, Paolo
    BLOOD PRESSURE MONITORING, 2010, 15 (05) : 281 - 284
  • [42] Is the oscillometric blood pressure measuring device in accord with the intra-arterial invasive blood pressure measuring method?
    Bae, Jang-Whan
    Joo, Hye Jin
    Lee, Won-Yik
    Lee, Sang Yeob
    Lee, Ju-Hee
    Kim, Dong-Woon
    Cho, Myeong-Chan
    Lee, Chung-Suk
    Kim, Eun-Kyong
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 137 : S20 - S21
  • [43] A comparative study of an ambulatory blood pressure measuring device and a wrist blood pressure monitor with a position sensor versus a mercury sphygmomanometer
    Altunkan, Sekip
    Genc, Yasemin
    Altunkan, Erkan
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2007, 18 (02) : 118 - 123
  • [44] A new blood pressure prediction method using wrist pulse examination
    Sukesh Rao M
    Rathnamala Rao
    Health and Technology, 2020, 10 : 689 - 697
  • [45] Blood Pressure Estimation Based on Photoplethysmography: Finger Versus Wrist
    Paliakaite, Birute
    Charlton, Peter H.
    Rapalis, Andrius
    Plusciauskaite, Vilma
    Piartli, Povilas
    Kaniusas, Eugenijus
    Marozas, Vaidotas
    2021 COMPUTING IN CARDIOLOGY (CINC), 2021,
  • [46] A new blood pressure prediction method using wrist pulse examination
    Rao, Sukesh M.
    Rao, Rathnamala
    HEALTH AND TECHNOLOGY, 2020, 10 (03) : 689 - 697
  • [47] Accuracy of the Omron RX-M, an automated blood pressure measuring device, measuring blood pressure at the wrist, according to a modified British Hypertension Society protocol
    Braam, RL
    Aslan, B
    Thien, T
    BLOOD PRESSURE MONITORING, 2004, 9 (01) : 25 - 30
  • [48] DEMONSTRATION OF AN IMPROVED METHOD FOR MEASURING BLOOD PRESSURE IN BIRDS
    STURKIE, PD
    DURFEE, W
    SHEAHAN, M
    POULTRY SCIENCE, 1957, 36 (05) : 1160 - 1161
  • [49] A METHOD OF MEASURING DIRECT ARTERIAL BLOOD-PRESSURE
    SCULLY, P
    CERVONI, P
    CHAN, PS
    TILLEY, LP
    CANINE PRACTICE, 1983, 10 (03) : 24 - &
  • [50] A NEW METHOD OF MEASURING BLOOD-PRESSURE IN MICE
    HICKS, JD
    GILTINAN, P
    PYE, J
    LANCET, 1965, 2 (7419): : 930 - &