Midterm clinical experience with a complex-shaped detachable platinum coil system for the treatment of cerebral aneurysms: Trufill DCS Orbit detachable coil system registry interim results

被引:11
|
作者
Hirsch, Joshua A. [1 ,2 ]
Bendok, Bernard R. [3 ,4 ]
Paulsen, Richard D. [5 ]
Cognard, Christophe [6 ]
Campos, Jorge [7 ]
Cronqvist, Mats [8 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02214 USA
[2] Massachusetts Gen Hosp, Dept Neurosurg, Boston, MA 02214 USA
[3] Northwestern Univ, Dept Neurosurg, Chicago, IL 60611 USA
[4] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[5] Jewish Med Ctr, Dept Radiol, Louisville, KY USA
[6] Univ Toulouse, Hop Purpan, Dept Neuroradiol, Toulouse, France
[7] Hosp Santa Maria, Dept Neuroradiol, Lisbon, Portugal
[8] Univ Lund Hosp, Dept Neuroradiol, S-22185 Lund, Sweden
关键词
D O I
10.1016/j.jvir.2007.07.020
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To report an interim analysis of the registry data and evaluate the performance of Trufill DCS Orbit coils in terms of the stability of initial aneurysmal occlusion. MATERIALS AND METHODS: From May 1, 2004, to February 1, 2006, 291 patients with ruptured or unruptured aneurysms were enrolled in a multiple-center global registry from 37 centers in the United States, Europe, and Latin America to be treated via endovascular embolization with Trufill DCS Orbit detachable platinum coils. Acute and long-term anatomic and clinical data were collected and evaluated. RESULTS: Initially, complete obliteration was reported in 187 of 300 treated aneurysms (62.3%) for which data were available; one treated aneurysm had no initial occlusion data. At follow-up (<= 1 year), 99 aneurysms were assessed. For 56 aneurysms with initial complete obliteration, 49 (87.5%) remained stable. The overall grade of occlusion of 99 aneurysms remained stable or improved in 81 cases (81.8%). Recanalization was seen in 16.2% of aneurysms (15 cases of coil compaction and one case of aneurysm growth); two aneurysms (2.0%) had coil migration. Five aneurysms (5.1%) underwent repeat treatment. CONCLUSIONS: The use of Trufill DCS Orbit coils for the endovascular occlusion of aneurysms allowed a favorable rate of initial complete obliteration, high packing density, and aneurysmal stability at follow-up as long as 1 year. Longer-term follow-up is needed to determine the long-term stability of aneurysmal occlusion.
引用
收藏
页码:1487 / 1494
页数:8
相关论文
共 19 条
  • [1] Complex shaped detachable platinum coil system for the treatment of cerebral aneurysms: The Codman Trufill DCS and Trufill DCS Orbit Detachable Coil System COMPLEX Registry final results
    Bendok, Bernard R.
    Rahme, Rudy J.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 (01) : 54 - 61
  • [2] Initial clinical experience with a new complex-shaped detachable platinum coil system for the treatment of intracranial cerebral aneurysms - The cordis trufill DCS detachable coil system
    Higashida, R. T.
    Cognard, C.
    Bracard, S.
    INTERVENTIONAL NEURORADIOLOGY, 2006, 12 (02): : 123 - 130
  • [3] Endovascular treatment of berry intracranial aneurysms using a new detachable coil system -: (DCS® Detachable Coil System Cook)
    Tournade, A
    Riquelme, C
    Musacchio, M
    Mont'alverne, F
    INTERVENTIONAL NEURORADIOLOGY, 2001, 7 (02): : 93 - 102
  • [4] Embolization of incidental cerebral aneurysms by using the Guglielmi detachable coil system
    Murayama, Y
    Viñuela, F
    Duckwiler, GR
    Gobin, YP
    Guglielmi, G
    JOURNAL OF NEUROSURGERY, 1999, 90 (02) : 207 - 214
  • [5] Combined use of TruFill DCS detachable coil system and Guglielmi detachable coil for embolization of meningioma fed by branches of the cavernous internal carotid artery - Technical case report
    Kusaka, Noboru
    Tamiya, Takashi
    Sugiu, Kenji
    Tokunaga, Koji
    Nishiguchi, Mitsuhisa
    Takayama, Kazuhiro
    Maeda, Yasuhiko
    Ogihara, Kotaro
    Nakagawa, Minoru
    Nishiura, Tsukasa
    NEUROLOGIA MEDICO-CHIRURGICA, 2007, 47 (01) : 29 - 31
  • [6] Short-term outcome for saccular cerebral aneurysms treated with the Orbit Galaxy Detachable Coil System
    Koltz, Michael T.
    Chalouhi, Nohra
    Tjoumakaris, Stavropoula
    Gonzalez, L. Fernando
    Dumont, Aaron
    Hasan, David
    Rosenwasser, Robert
    Jabbour, Pascal
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (01) : 148 - 152
  • [7] Angiographical follow-up results of cerebral aneurysms treated by Guglielmi detachable coil system
    Hyogo, T
    Kataoka, T
    Hayase, K
    Nakamura, H
    INTERVENTIONAL NEURORADIOLOGY, 2001, 7 : 137 - 142
  • [8] Safety of endovascular treatment of intracranial aneurysms with a new, complex shaped Guglielmi detachable coil
    Christian A. Taschner
    Xavier Leclerc
    Jean-Yves Gauvrit
    Anis Kerkeni
    Mohamed El-Mahdy
    Jean-Paul Lejeune
    Jean-Pierre Pruvo
    Neuroradiology, 2007, 49 : 761 - 766
  • [9] Safety of endovascular treatment of intracranial aneurysms with a new, complex shaped Guglielmi detachable coil
    Taschner, Christian A.
    Leclerc, Xavier
    Gauvrit, Jean-Yves
    Kerkeni, Anis
    El-Mahdy, Mohamed
    Lejeune, Jean-Paul
    Pruvo, Jean-Pierre
    NEURORADIOLOGY, 2007, 49 (09) : 761 - 766
  • [10] Intracranial aneurysms treated with the Guglielmi detachable coil: midterm clinical results in a consecutive series of 100 patients
    Malisch, TW
    Guglielmi, G
    Vinuela, F
    Duckwiler, G
    Gobin, YP
    Martin, NA
    Frazee, JG
    JOURNAL OF NEUROSURGERY, 1997, 87 (02) : 176 - 183