PETALO: Time-of-Flight PET with liquid xenon

被引:2
|
作者
Romo-Luque, C. [1 ,2 ]
机构
[1] CSIC, Inst Fis Corpuscular IFIC, Calle Catedratico Jose Beltran 2, Valencia 46980, Spain
[2] Univ Valencia, Calle Catedratico Jose Beltran 2, Valencia 46980, Spain
基金
欧盟地平线“2020”; 欧洲研究理事会;
关键词
PET; TOF; Liquid xenon; Coincidence resolving time (CRT); SiPMs; DETECTOR;
D O I
10.1016/j.nima.2019.162397
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Liquid xenon offers several features, which make it suitable for applications in nuclear medicine, such as high scintillation yield and fast scintillation decay time. Moreover, being a continuous medium with a uniform response, liquid xenon allows one to avoid most of the geometrical distortions of conventional detectors based on scintillating crystals. In this paper, we describe how these properties have motivated the development of a novel concept for positron emission tomography scanners with Time-Of-Flight measurement, which combines a liquid xenon scintillating volume and silicon photomultipliers as sensors. A Monte Carlo investigation has pointed out that this technology would provide an excellent intrinsic time resolution, down to 70 ps. Also, the transparency of liquid xenon to UV and blue wavelengths opens the possibility of exploiting both scintillation and Cherenkov light for a high-sensitivity positron emission tomography scanner with Time-Of-Flight capabilities. Monte Carlo simulations point to a time resolution of 30-50 ps obtained using Cherenkov light. A prototype is being built to demonstrate the high resolution in energy, time and reconstruction of spatial coordinates of this concept, using a ring of 30 cm internal diameter and a depth of 3 cm instrumented with VUV-sensitive silicon photomultipliers.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] PETALO: Time-of-Flight PET with liquid xenon
    Ferrario, Paola
    Herrero-Bosch, Vicente
    Maria Benlloch-Rodriguez, Jose
    Romo-Luque, Carmen
    Jose Gomez-Cadenas, Juan
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [2] Time-of-Flight PET
    Lewellen, TK
    SEMINARS IN NUCLEAR MEDICINE, 1998, 28 (03) : 268 - 275
  • [3] Time-of-flight positron emission tomography using liquid xenon scintillation
    Doke, T.
    Kikuchi, J.
    Nishikido, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (03): : 863 - 871
  • [4] Advances in time-of-flight PET
    Surti, Suleman
    Karp, Joel S.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01): : 12 - 22
  • [5] Evaluation of Fourier rebinning of time-of-flight PET data to non time-of-flight
    Li, Quanzheng
    Cho, S.
    Ahn, S.
    Ren, R.
    Leahy, R.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [6] Improving time resolution in time-of-flight PET
    Conti, Maurizio
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S194 - S198
  • [7] Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector
    Renner, J.
    Romo-Luque, C.
    Aliaga, R. J.
    Alvarez, V.
    Ballester, F.
    Benlloch-Rodriguez, J. M.
    Carrion, J. V.
    Cubero, D.
    Diaz, J.
    Esteve, R.
    Gadea, R.
    Generowicz, J.
    Gillam, J.
    Lopez-Gomez, J. L.
    Martinez, A.
    Monrabal, F.
    Querol, M.
    Rappaport, M.
    Rodriguez, J.
    Rodriguez-Ponce, J.
    Solevi, P.
    Teruel-Pardo, S.
    Toledo, J. F.
    Torres-Curado, R.
    Herrero-Bosch, V.
    Gomez-Cadenas, J. J.
    Ferrario, P.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (05)
  • [8] Update on Time-of-Flight PET Imaging
    Surti, Suleman
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (01) : 98 - 105
  • [9] OPTIMIZATION OF DETECTORS FOR TIME-OF-FLIGHT PET
    Moszynski, Marek
    Szczesniak, Tomasz
    WORKSHOP ON TIMING DETECTORS: ELECTRONICS, MEDICAL AND PARTICLE PHYSICS APPLICATIONS, 2010, 4 (01): : 59 - 64
  • [10] Clinical impact of time-of-flight PET
    Soussan, M.
    Galas, J-L
    Ouvrier, M-J
    Pop, G.
    Neuman, A.
    Weinmann, P.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2011, 35 (07): : 401 - 405