Effect of ProTaper Gold, Self-Adjusting File, and XP-endo Shaper Instruments on Dentinal Microcrack Formation: A Micro-computed Tomographic Study

被引:46
|
作者
Bayram, H. Melike [1 ]
Bayram, Emre [1 ]
Ocak, Mert [2 ]
Uygun, Ahmet Demirhan [3 ]
Celik, Hakan Hamdi [2 ]
机构
[1] Gaziosmanpasa Univ, Fac Dent, Dept Endodont, TR-60200 Tokat, Turkey
[2] Hacettepe Univ, Fac Med, Dept Anat, Ankara, Turkey
[3] Recep Tayyip Erdogan Univ, Fac Dent, Dept Endodont, Rize, Turkey
关键词
Dentinal defects; micro-computed tomographic imaging; microcracks; nickel-titanium file system; root canal preparation; ROOT-CANAL PREPARATIONS; CRACK FORMATION; UNIVERSAL; RECIPROCATION; MOVEMENT; SYSTEMS;
D O I
10.1016/j.joen.2017.02.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of the present study was to evaluate the frequency of dentinal microcracks observed after root canal preparation with ProTaper Universal (PTU; Dentsply Tulsa Dental Specialties, Tulsa, OK), ProTaper Gold (PTG; Dentsply Tulsa Dental Specialties), Self Adjusting File (SAF; ReDent Nova, Ra'anana, Israel), and XP-endo Shaper (XP; FKG Dentaire, La Chaux-de-Fonds, Switzerland) instruments using micro computed tomographic (CT) analysis. Methods: Forty extracted human mandibular premolars having single-canal and straight root were randomly assigned to 4 experimental groups (n = 10) according to the different nickel titanium systems used for root canal preparation: PTU, PTG, SAF, and XP. In the SAF and XP groups, the canals were first prepared with a K-file until #25 at the working length, and then the SAF or XP files were used. The specimens were scanned using high-resolution micro computed tomographic imaging before and after root canal preparation. Afterward, preoperative and postoperative cross-sectional images of the teeth were screened to identify the presence of dentinal defects. For each group, the number of microcracks was determined as a percentage rate. The McNemar test was used to determine significant differences before and after instrumentation. The level of significance was set at P < .05. Results: The PTU system significantly increased the percentage rate of microcracks compared with preoperative specimens (P < .05). No new dentinal microcracks were observed in the PTG, SAF, or XP groups. Conclusions: Root canal preparations with the PTG, SAF, and XP systems did not induce the formation of new dentinal microcracks on straight root canals of mandibular premolars.
引用
收藏
页码:1166 / 1169
页数:4
相关论文
共 31 条
  • [1] Effect of Reciproc blue, XP-endo shaper, and WaveOne gold instruments on dentinal microcrack formation: A micro-computed tomographic evaluation
    Aydin, Zeliha Ugur
    Keskin, Neslihan Busra
    Ozyurek, Taha
    MICROSCOPY RESEARCH AND TECHNIQUE, 2019, 82 (06) : 856 - 860
  • [2] Evaluation of XP-endo Shaper, Reciproc Blue, and ProTaper Universal NiTi Systems on Dentinal Microcrack Formation Using Micro-Computed Tomography
    Aksoy, Cagman
    Keris, Elif Yildizer
    Yaman, Sis Darendeliler
    Ocak, Mert
    Geneci, Ferhat
    Celik, Hakan Hamdi
    JOURNAL OF ENDODONTICS, 2019, 45 (03) : 338 - 342
  • [3] Dentinal Microcrack Formation after Root Canal Instrumentation by XP-Endo Shaper and ProTaper Universal: A Microcomputed Tomography Evaluation
    Alkahtany, Sarah M.
    Al-Madi, Ebtissam M.
    INTERNATIONAL JOURNAL OF DENTISTRY, 2020, 2020
  • [4] Shaping ability of XP-endo Shaper and ProTaper Next in long oval-shaped canals: a micro-computed tomography study
    Velozo, C.
    Silva, S.
    Almeida, A.
    Romeiro, K.
    Vieira, B.
    Dantas, H.
    Sousa, F.
    De Albuquerque, D. S.
    INTERNATIONAL ENDODONTIC JOURNAL, 2020, 53 (07) : 998 - 1006
  • [5] TRUShape Versus XP-endo Shaper: A Micro-computed Tomographic Assessment and Comparative Study of the Shaping Ability-An In Vitro Study
    Perez Morales, Maria de las Nieves
    Gonzalez Sanchez, Jose Antonio
    Olivieri Fernandez, Juan Gonzalo
    Laperre, Kjell
    Abella Sans, Francesc
    Jaramillo, David E.
    Duran-Sindreu Terol, Fernando
    JOURNAL OF ENDODONTICS, 2020, 46 (02) : 271 - 276
  • [6] Micro-computed Tomographic Assessment on the Effect of ProTaper Next and Twisted File Adaptive Systems on Dentinal Cracks
    De-Deus, Gustavo
    Belladonna, Felipe Goncalves
    Souza, Erick Miranda
    Nogueira Leal Silva, Emmanuel Joao
    Neves, Aline de Almeida
    Alves, Haimon
    Lopes, Ricardo Tadeu
    Versiani, Marco Aurelio
    JOURNAL OF ENDODONTICS, 2015, 41 (07) : 1116 - 1119
  • [7] Dentinal Microcrack Formation during Root Canal Preparations by Different NiTi Rotary Instruments and the Self-Adjusting File
    Yoldas, Oguz
    Yilmaz, Sehnaz
    Atakan, Gokhan
    Kuden, Cihan
    Kasan, Zeynep
    JOURNAL OF ENDODONTICS, 2012, 38 (02) : 232 - 235
  • [8] Micro-computed Tomographic Evaluation of Dentinal Microcracks after Preparation of Curved Root Canals with ProTaper Gold, WaveOne Gold, and ProTaper Next Instruments
    Miguens-Vila, Ramon
    Martin-Biedma, Benjamin
    De-Deus, Gustavo
    Belladonna, Felipe G.
    Pena-Lopez, Alejandro
    Castelo-Baz, Pablo
    JOURNAL OF ENDODONTICS, 2021, 47 (02) : 309 - 314
  • [9] Effects of preparation with the Self-Adjusting File, TRUShape and XP-endo Shaper systems, and a supplementary step with XP-endo Finisher R on filling material removal during retreatment of mandibular molar canals
    Machado, A. G.
    Guilherme, B. P. S.
    Provenzano, J. C.
    Marceliano-Alves, M. F.
    Goncalves, L. S.
    Siqueira, J. F.
    Neves, M. A. S.
    INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (05) : 709 - 715
  • [10] Micro-Computed Tomographic Analysis of the Shaping Ability of XP-Endo Shaper in Oval-Shaped Distal Root Canals of Mandibular Molars
    Poly, Ane
    Tseng, Wei-Ju Louis
    Marques, Fernando
    Setzer, Frank Carsten
    Karabucak, Bekir
    EUROPEAN ENDODONTIC JOURNAL, 2021, 6 (03): : 271 - 277