Determination of estrogenic steroids in surface water and wastewater by liquid chromatography-electrospray tandem mass spectrometry

被引:54
|
作者
Zuehlke, S
Duennbier, U
Heberer, T
机构
[1] Fed Inst Risk Assessment, D-14195 Berlin, Germany
[2] Berlin Water Co, Dept Labs, D-10631 Berlin, Germany
[3] Tech Univ Berlin, Inst Food Chem, D-13355 Berlin, Germany
关键词
water analysis; endocrine disrupting compounds; estrogenic steroids; low sample volume;
D O I
10.1002/jssc.200301727
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method is presented which permits trace level determination of 17alpha-ethynylestradiol (EE2), 17beta-estradiol (E2), and estrone (E1). Using this method, the estrogenic steroids were analyzed in drinking water, surface water, and wastewater (sewage influents and effluents) at concentrations down to 0.1 ng/L. Sample volumes between 100 and 500 mL are concentrated using automated solid-phase extraction. Analysis is performed by liquid chromatography with detection by tandem mass spectrometry. Applying simple clean-up procedures and internal standard calibration, recovery losses resulting from matrix-dependent ion suppression during electrospray ionization could be compensated for all of the investigated compounds. Recoveries around 100% were obtained for all analytes after correction using the internal standards. Limits of quantification (LOQ) were between 0.1 and 0.4 ng/L for purified sewage, surface, ground, and drinking water and between 1 and 2 ng/L in the case of raw sewage. Water treatment by wastewater treatment plants (WWTPs) or by a surface water treatment plant affected the removal of all estrogenic steroids. Thus, E1, E2, and EE2 were removed in the municipal WWTPs to the extent of 93%, 93%, and 80%, respectively. In the effluents of the WWTP in Ruhleben (Berlin, Germany), E1, E2, and EE2 were detected at the low ng/L level. E2 and EE2 were, however, not present in the Berlin surface water above the LOQ (0.2 ng/L). El was the only compound that could be detected in surface water samples. After additional surface water treatment it was still detectable but only at trace-level concentrations with a mean value of 0.16 ng/L.
引用
收藏
页码:52 / 58
页数:7
相关论文
共 50 条
  • [1] Determination of neutral pharmaceuticals in wastewater and rivers by liquid chromatography-electrospray tandem mass spectrometry
    Ternes, T
    Bonerz, M
    Schmidt, T
    JOURNAL OF CHROMATOGRAPHY A, 2001, 938 (1-2) : 175 - 185
  • [2] Trace analysis of 28 steroids in surface water, wastewater and sludge samples by rapid resolution liquid chromatography-electrospray ionization tandem mass spectrometry
    Liu, Shan
    Ying, Guang-Guo
    Zhao, Jian-Liang
    Chen, Feng
    Yang, Bin
    Zhou, Li-Jun
    Lai, Hua-jie
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (10) : 1367 - 1378
  • [3] Determination of hexaconazole in surface water samples from river and the sea by liquid chromatography-electrospray tandem mass spectrometry
    Tsukatani, Hiroko
    Tobiishi, Kazuhiro
    Tanaka, Yoshito
    Sakuragi, Kenji
    Ikeura, Tasoh
    Nakamura, Matayoshi
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2008, 72 (01) : 149 - 154
  • [4] Liquid chromatography-electrospray mass spectrometry and tandem mass spectrometry of ceramides
    Raith, K
    Neubert, RHH
    ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) : 295 - 303
  • [5] Determination of Antibiotics in Brazilian Surface Waters Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry
    Locatelli, Marco Antonio F.
    Sodre, Fernando F.
    Jardim, Wilson F.
    ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2011, 60 (03) : 385 - 393
  • [6] Determination of trinexapac in wheat by liquid chromatography-electrospray ionization tandem mass spectrometry
    Hiemstra, M
    De Kok, A
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (20) : 5855 - 5860
  • [7] Determination of quaternary ammonium pesticides by liquid chromatography-electrospray tandem mass spectrometry
    Castro, R
    Moyano, E
    Galceran, MT
    JOURNAL OF CHROMATOGRAPHY A, 2001, 914 (1-2) : 111 - 121
  • [8] Determination of gestrinone in human serum by liquid chromatography-electrospray tandem mass spectrometry
    Wang, QG
    Wu, ZP
    Wang, YM
    Luo, GA
    Wu, E
    Gao, XF
    JOURNAL OF CHROMATOGRAPHY B, 2000, 746 (02): : 151 - 159
  • [9] Determination of Glucocorticoids in Muscle Tissues by Liquid Chromatography-Electrospray Tandem Mass Spectrometry
    Gong Lan
    Chen Ming
    Wei Xian
    Zou Chun
    Wang Ran
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (01) : 74 - 80
  • [10] Ultra-pressure liquid chromatography-electrospray tandem mass spectrometry for multiresidue determination of pesticides in water
    Gervais, G.
    Brosillon, S.
    Laplanche, A.
    Helen, C.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1202 (02) : 163 - 172