Relations Between Beat-to-Beat Microcirculatory Blood Flow and Variations Therein

被引:11
|
作者
Hsiu, Hsin [1 ]
Hsu, Chia-Liang [1 ]
Jan, Ming-Yie [2 ]
机构
[1] Yuan Ze Univ, Dept Elect Engn, Tao Yuan, Taiwan
[2] Acad Sinica, Inst Phys, Biophys Lab, Taipei, Taiwan
关键词
HEART-RATE; SKIN; ACUPUNCTURE; FLUCTUATIONS; CONNECTION; HUMANS; PULSE;
D O I
10.1089/pho.2009.2690
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Analyzing the beat-to-beat cardiovascular variability (e. g., heart-rate variability analysis) provides important information regarding circulatory autonomic control. The present study aimed to use laser Doppler flowmetry (LDF) and beat-to-beat analysis to elucidate changes in the microcirculatory blood flow (MBF) and variations (MBFV) therein induced by local heating stimulation. Method: For each experiment, we applied nonpainful local heating and recorded a 20-min heating effect, which was segmented into four measurements separated by 5 min as M1-M4. DCflux (average LDF flux) was calculated for each pulse, and the coefficient of variance of DCflux (DCCV) was then calculated to evaluate the beat-to-beat MBFV. Results: In the linear regression analysis of the M2-M4 data sequence, the slope between relative changes (compared with M1 values) in DCCV and DCflux, and those between the proceeding DCCV and the subsequent DCflux, were negative (R-2 > 0.40 for all; p < 0.05). Conclusion: This is the first study to reveal a possible time-domain relationship between changes in MBF and MBFV parameters. Our results suggest that MBFV evaluated from the beat-to-beat LDF waveform is useful for monitoring the microcirculatory regulatory activities of arteriolar openings, and might therefore be particularly meaningful when evaluating treatment techniques or drugs aimed at improving microcirculatory perfusion.
引用
收藏
页码:785 / 792
页数:8
相关论文
共 50 条
  • [1] An Alternative Index for Monitoring Microcirculatory Blood Flow: The Beat-to-beat Microcirculatory Blood Flow Variability
    Hsiu, Hsin
    Hsu, Wei-Chen
    Hsu, Chia Liang
    2009 INTERNATIONAL CONFERENCE ON BIOMEDICAL AND PHARMACEUTICAL ENGINEERING, 2009, : 45 - +
  • [2] Recovery of beat-to-beat variations of QRS
    K. Lund
    E. H. Christiansen
    B. Lund
    A. K. Pedersen
    Medical and Biological Engineering and Computing, 1998, 36 : 438 - 444
  • [3] Recovery of beat-to-beat variations of QRS
    Lund, K.
    Christiansen, E.H.
    Lund, B.
    Pedersen, A.K.
    Medical and Biological Engineering and Computing, 1998, 36 (04): : 438 - 444
  • [4] Recovery of beat-to-beat variations of QRS
    Lund, K
    Christiansen, EH
    Lund, B
    Pedersen, AK
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (04) : 438 - 444
  • [5] Biophysical Model for Beat-to-Beat Variations of Vectorcardiogram
    Aidu, E. A. I.
    Trunov, V. G.
    Titomir, L. I.
    MEASUREMENT SCIENCE REVIEW, 2009, 9 (03): : 64 - 66
  • [6] A REAPPRAISAL OF THE METHODS TESTING BEAT-TO-BEAT VARIATIONS
    MEHLSEN, J
    PAGH, K
    SESTOFT, L
    LEVINNIELSEN, S
    ACTA ENDOCRINOLOGICA, 1982, 100 : 48 - 48
  • [7] Beat-to-Beat Blood Pressure Variations While Standing are Associated with Postural Changes in Blood Pressure
    Goh, C. H.
    Ng, S. C.
    Tan, M. P.
    INTERNATIONAL CONFERENCE FOR INNOVATION IN BIOMEDICAL ENGINEERING AND LIFE SCIENCES, ICIBEL2015, 2016, 56 : 44 - 48
  • [8] Beat-to-beat fluctuations in blood flow in humans are more related between upper limbs than between lower limbs
    Padilla, Jaume
    Fairfax, Seth T.
    Vianna, Lauro C.
    Davis, Michael J.
    Laughlin, M. Harold
    Fadel, Paul J.
    FASEB JOURNAL, 2012, 26
  • [9] BEAT-TO-BEAT RELATIONSHIPS BETWEEN BLOOD-PRESSURE AND CEREBRAL BLOOD-FLOW VELOCITY IN THE PREMATURE-INFANT
    BIGNALL, S
    KITNEY, RI
    RIVERS, RPA
    STRAUGHAN, K
    JOURNAL OF PHYSIOLOGY-LONDON, 1989, 413 : P25 - P25
  • [10] Ambulatory and beat-to-beat blood pressure variability: Are they related?
    Sloan, RP
    Shapiro, PA
    Bagiella, E
    McKinley, PS
    Myers, MM
    Brondolo, EN
    Eichler, B
    PSYCHOSOMATIC MEDICINE, 2001, 63 (01): : 172 - 172