Frequency of Adequate Contrast Opacification of the Major Intracranial Venous Structures with CT Angiography in the Setting of Intracerebral Hemorrhage: Comparison of 16- and 64-Section CT Angiography Techniques

被引:2
|
作者
Almandoz, J. E. Delgado [1 ,2 ]
Su, H. S. [2 ]
Schaefer, P. W. [2 ]
Goldstein, J. N. [3 ]
Pomerantz, S. R. [2 ]
Lev, M. H. [2 ]
Gonzalez, R. G. [2 ]
Romero, J. M.
机构
[1] Washington Univ, Div Neuroradiol, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[2] Harvard Univ, Sch Med, Dept Radiol, Massachusetts Gen Hosp,Div Neuroradiol, Boston, MA 02115 USA
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Emergency Med, Boston, MA USA
关键词
SPOT SIGN; HEMATOMA EXPANSION; HIGHEST RISK; EXTRAVASATION; THROMBOSIS; ETIOLOGY; SCORE;
D O I
10.3174/ajnr.A2388
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DVST is an important cause of ICH because its treatment may require anticoagulation or mechanical thrombectomy. We aimed to determine the frequency of adequate contrast opacification of the major intracranial venous structures in CTAs performed for ICH evaluation, which is an essential factor in excluding DVST as the ICH etiology. MATERIALS AND METHODS: Two readers retrospectively reviewed CTAs performed in 170 consecutive patients with ICH who presented to our emergency department during a 1-year period to determine by consensus whether qualitatively, contrast opacification in each of the major intracranial venous structures was adequate to exclude DVST. "Adequate contrast opacification" was defined as homogeneous opacification of the venous structure examined. "Inadequate contrast opacification" was defined as either inhomogeneous opacification or nonopacification of the venous structure examined. Delayed scans, if obtained, were reviewed by the same readers blinded to the first-pass CTAs to determine the adequacy of contrast opacification in the venous structures according to the same criteria. In patients who did not have an arterial ICH etiology, the same readers determined if thrombosis of an inadequately opacified intracranial venous structure could have potentially explained the ICH by correlating the presumed venous drainage path of the ICH with the presence of inadequate contrast opacification within the venous structure draining the venous territory of the ICH. CTAs were performed in 16- or 64-section CT scanners with bolus-tracking, scanning from Cl to the vertex. Patients with a final diagnosis of DVST were excluded. We used the Pearson chi(2) test to determine the significance of the differences in the frequency of adequate contrast opacification within each of the major intracranial venous structures in scans obtained using either a 16- or 64-section MDCTA technique. RESULTS: Fifty-eight patients were evaluated with a 16-section MDCTA technique (34.1%) and 112 with a 64-section technique (65.9%). Adequate contrast opacification within all major noncavernous intracranial venous structures was significantly less frequent in first-pass CTAs performed with a 64-section technique (33%) than in those performed with a 16-section technique (60%, P value <.0001). Delayed scans were obtained in 50 patients, all of which demonstrated adequate contrast opacification in the major noncavernous intracranial venous structures. In 142 patients with supratentorial or cerebellar ICH without an underlying arterial etiology, we found that thrombosis of an inadequately opacified major intracranial venous structure could have potentially explained the ICH in 38 patients (26.8%), most examined with a 64-section technique (86.8%). CONCLUSIONS: Inadequate contrast pacification of the major intracranial venous structures is common in first-pass CTAs performed for ICH evaluation, particularly if performed with a 64-section technique. Acquiring delayed scans appears necessary to confidently exclude DVST when there is strong clinical or radiologic suspicion.
引用
收藏
页码:839 / 845
页数:7
相关论文
共 15 条
  • [1] Frequency of Adequate Contrast Opacification of the Dural Venous Sinuses With CT Angiography in the Setting of Intracerebral Hemorrhage: Comparison of 16 and 64-Slice CT Angiography Techniques
    Almandoz, Josser E. Delgado
    Su, Henry S.
    Schaefer, Pamela W.
    Pomerantz, Stuart R.
    Lev, Michael H.
    Gonzalez, R. Gilberto
    Romero, Javier M.
    STROKE, 2010, 41 (04) : E312 - E313
  • [2] 64-section multidetector CT angiography for evaluation of intracranial aneurysms: comparison with 3D rotational angiography
    Li, Qi
    Lv, Fajin
    Yao, Guoen
    Li, Yongmei
    Xie, Peng
    ACTA RADIOLOGICA, 2014, 55 (07) : 840 - 846
  • [3] 64-section CT angiography in patients with critical limb ischaemia and severe claudication: Comparison with digital subtractive angiography
    Fotiadis, N.
    Kyriakides, C.
    Bent, C.
    Vorvolakos, T.
    Matson, M.
    CLINICAL RADIOLOGY, 2011, 66 (10) : 945 - 952
  • [4] Contrast-enhanced 64-section coronary multidetector CT angiography versus conventional coronary angiography for Stent assessment
    Das, K. M.
    El-Menyar, Ayman A.
    Salam, Amar M.
    Singh, Rajvir
    Dabdoob, Wafer Amin K.
    Albinali, Hajar A.
    Al Suwaidi, Jassim
    RADIOLOGY, 2007, 245 (02) : 424 - 432
  • [5] Evaluation of 64-Section CT Angiography for Detection and Treatment Planning of Intracranial Aneurysms by Using DSA and Surgical Findings
    Li, Qi
    Lv, Fajin
    Li, Yongmei
    Luo, Tianyou
    Li, Kewei
    Xie, Peng
    RADIOLOGY, 2009, 252 (03) : 808 - 815
  • [6] Functionally relevant coronary artery disease: Comparison of 64-section CT angiography with myocardial perfusion SPECT
    Gaemperli, Oliver
    Schepis, Tiziano
    Valenta, Ines
    Koepfli, Pascal
    Husmann, Lars
    Scheffel, Hans
    Leschka, Sebastian
    Eberli, Franz R.
    Luscher, Thomas F.
    Alkadhi, Hatem
    Kaufmann, Philipp A.
    RADIOLOGY, 2008, 248 (02) : 414 - 423
  • [7] Detection of aneurysms by 64-section multidetector CT angiography in patients acutely suspected of having an intracranial aneurysm and comparison with digital subtraction and 3D rotational angiography
    McKinney, A. M.
    Palmer, C. S.
    Truwit, C. L.
    Karagulle, A.
    Teksam, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (03) : 594 - 602
  • [8] Dual-Source versus 64-Section CT Coronary Angiography at Lower Heart Rates: Comparison of Accuracy and Radiation Dose
    Baumueller, Stephan
    Leschka, Sebastian
    Desbiolles, Lotus
    Stolzmann, Paul
    Scheffel, Hans
    Seifert, Burkhardt
    Marincek, Borut
    Alkadhi, Hatem
    RADIOLOGY, 2009, 253 (01) : 56 - 64
  • [9] Coronary arteries: Diagnostic performance of 16-versus 64-section spiral CT compared with invasive coronary angiography-meta-analysis
    Hamon, Michele
    Morello, Remy
    Riddell, John W.
    Hamon, Martial
    RADIOLOGY, 2007, 245 (03) : 720 - 731
  • [10] Carotid artery stents on CT angiography: In vitro comparison of different stent designs and sizes using 16-, 64-and 320-row CT scanners
    Lettau, Michael
    Kotter, Elmar
    Bendszus, Martin
    Haehnel, Stefan
    JOURNAL OF NEURORADIOLOGY, 2014, 41 (04) : 259 - 268