Reliability of a new method for coronary artery calcium or metal subtraction by 320-row cardiac CT

被引:20
|
作者
Vilades Medel, David [1 ,2 ]
Leta, Ruben [1 ,2 ]
Alomar Serralach, Xavier [2 ]
Carreras Costa, Francesc [1 ,2 ]
Pons-Llado, Guillem [1 ,2 ]
机构
[1] Univ Autonoma Barcelona, Cardiac Imaging Unit, Dept Cardiol, Hosp Santa Creu & St Pau, St Antoni Maria Claret 167, Barcelona 08025, Spain
[2] Univ Autonoma Barcelona, Clin Creu Blanca, St Antoni Maria Claret 167, Barcelona 08025, Spain
关键词
Cardiac CTA; Subtraction CTA; Artefact; Coronary calcium subtraction; Metal stents; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; RADIATION-EXPOSURE; ANGIOGRAPHY; QUANTIFICATION; FEASIBILITY;
D O I
10.1007/s00330-015-4130-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To investigate the feasibility and diagnostic accuracy of subtraction CTA on patients with highly calcified coronary artery disease (CAD) or previous implanted stents, in comparison with invasive coronary angiography (ICA). Twenty-three patients were recruited. All conventional and subtraction CTA exams were performed using a 320-row CT. Subjective image quality score was assessed for each segment using a 4-point scale: 1-uninterpretable to 4-good image quality. A total of 129 calcified or stented coronary segments were studied. Mean coronary image quality with conventional CTA was 2.73 +/- 0.97 and in subtracted CTA 3.3 +/- 0.92 (p < 0.01). After metal subtraction, image quality in stented coronary segments with > 3 mm of diameter improved from 2.69 +/- 0.97 to 3.34 +/- 0.89 (p = 0.01) and in those with < 3 mm of diameter from 2.11 +/- 0.78 to 2.67 +/- 0.87 (p = 0.17). There was an improvement in diagnostic accuracy to detect ICA stenosis > 50 % by subtraction CTA compared with conventional CTA (AUC 0.93 to 0.87; p = 0.02). Subtraction CTA is promising in overcoming limitations of conventional CTA due to calcium or metal artefacts, especially if no motion artefact is present or when stents > 3 mm are studied. aEuro cent Calcium and metal artefacts are still a limitation for conventional coronary CTA aEuro cent Diagnostic accuracy is improved by subtraction as compared with conventional CTA aEuro cent Subtraction CTA is a promising tool to overcome limitations of conventional CTA.
引用
收藏
页码:3208 / 3214
页数:7
相关论文
共 50 条
  • [1] Reliability of a new method for coronary artery calcium or metal subtraction by 320-row cardiac CT
    David Viladés Medel
    Rubén Leta
    Xavier Alomar Serralach
    Francesc Carreras Costa
    Guillem Pons-Lladó
    European Radiology, 2016, 26 : 3208 - 3214
  • [2] Coronary artery calcium and metal stent subtraction by 320-row cardiac-CT: fact or fiction?
    Vilades Medel, D.
    Leta Petracca, R.
    Carreras Costa, F.
    Alomar Serrallach, X.
    Pons Llado, G.
    EUROPEAN HEART JOURNAL, 2015, 36 : 866 - 866
  • [3] Impact of Subcutaneous Adipose Tissue on the Coronary Artery Calcium Score Assessed by 320-Row CT Coronary Angiography in Japanese Population
    Tanaka, Tetsu
    Kishi, Satoru
    Koseki, Keita
    Sato, Yu
    Okuno, Taishi
    Yahagi, Kazuyuki
    Komiyama, Kota
    Aoki, Jiro
    Ibukuro, Kenji
    Tanabe, Kengo
    CIRCULATION, 2017, 136
  • [4] Evaluation of CT coronary artery angiography with 320-row detector CT in a high-risk population
    Gang, S.
    Min, L.
    Li, L.
    Guo-Ying, L.
    Lin, X.
    Qun, J.
    Hua, Z.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1013): : 562 - 570
  • [5] The effect of heart rate on coronary plaque measurements in 320-row coronary CT angiography
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Sakabe, Daisuke
    Oda, Seitaro
    Nakaura, Takeshi
    Yuki, Hideaki
    Nagayama, Yasunori
    Hirata, Kenichiro
    Iyama, Yuji
    Namimoto, Tomohiro
    Yamashita, Yasuyuki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (12): : 1977 - 1985
  • [6] The effect of heart rate on coronary plaque measurements in 320-row coronary CT angiography
    Masafumi Kidoh
    Daisuke Utsunomiya
    Yoshinori Funama
    Daisuke Sakabe
    Seitaro Oda
    Takeshi Nakaura
    Hideaki Yuki
    Yasunori Nagayama
    Kenichiro Hirata
    Yuji Iyama
    Tomohiro Namimoto
    Yasuyuki Yamashita
    The International Journal of Cardiovascular Imaging, 2018, 34 : 1977 - 1985
  • [7] Minimizing the acquisition phase in coronary CT angiography using the second generation 320-row CT
    Tomizawa, Nobuo
    Kanno, Shigeaki
    Maeda, Eriko
    Akahane, Masaaki
    Torigoe, Rumiko
    Ohtomo, Kuni
    JAPANESE JOURNAL OF RADIOLOGY, 2014, 32 (07) : 391 - 396
  • [8] Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography
    Fuchs, Andreas
    Kuhl, J. Tobias
    Chen, Marcus Y.
    Helquist, Steffen
    Razeto, Marco
    Arakita, Kazumasa
    Steveson, Chloe
    Arai, Andrew E.
    Kofoed, Klaus F.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (05) : 393 - 398
  • [9] Minimizing the acquisition phase in coronary CT angiography using the second generation 320-row CT
    Nobuo Tomizawa
    Shigeaki Kanno
    Eriko Maeda
    Masaaki Akahane
    Rumiko Torigoe
    Kuni Ohtomo
    Japanese Journal of Radiology, 2014, 32 : 391 - 396
  • [10] Diagnostic accuracy of 320-row coronary CT angiography in the assessment of coronary in-stent restenosis
    Kishi, S.
    Tanabe, K.
    Yachi, S.
    Otsuka, T.
    Nakajima, Y.
    Taniwaki, M.
    Tanimoto, S.
    Aoki, J.
    Nakajima, H.
    Hara, K.
    EUROPEAN HEART JOURNAL, 2011, 32 : 524 - 524