摘要
Acoustic resolution photoacoustic Doppler velocimetry promises to overcome the spatial resolution and depth penetration limitations of current blood flow measuring methods. Despite successful implementation using blood-mimicking fluids, measurements in blood have proved challenging, thus preventing in vivo application. A common explanation for this difficulty is that whole blood is insufficiently heterogeneous relative to detector frequencies of tens of MHz compatible with deep tissue photoacoustic measurements. Through rigorous experimental measurements we provide new insight that refutes this assertion. We show for the first time that, by careful choice of the detector frequency and field-of-view, and by employing novel signal processing methods, it is possible to make velocity measurements in whole blood using transducers with frequencies in the tens of MHz range. These findings have important implications for the prospects of making deep tissue measurements of blood flow relevant to the study of microcirculatory abnormalities associated with cancer, diabetes, atherosclerosis and other conditions.
引用
收藏
页码:2789 / 2806
页数:18
相关论文
共 50 条
  • [1] Prospects for in vivo blood velocimetry using acoustic resolution photoacoustic Doppler
    Brunker, J.
    Beard, P.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2016, 2016, 9708
  • [2] Acoustic resolution photoacoustic Doppler velocity measurements in fluids using time-domain cross-correlation
    Brunker, J.
    Beard, P.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2013, 2013, 8581
  • [3] Acoustic resolution photoacoustic Doppler flowmetry: practical considerations for obtaining accurate measurements of blood flow
    Brunker, J.
    Beard, P.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2014, 2014, 8943
  • [4] Acoustic resolution photoacoustic Doppler flowmetry using a transducer array: optimising processing for velocity contrast
    Bucking, T. M.
    van den Berg, P. J.
    Balabani, S.
    Steenbergen, W.
    Beard, P. C.
    Brunker, J.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2017, 2017, 10064
  • [5] Acoustic resolution photoacoustic Doppler velocimetry in blood-mimicking fluids
    Brunker, Joanna
    Beard, Paul
    SCIENTIFIC REPORTS, 2016, 6
  • [6] Acoustic resolution photoacoustic Doppler velocimetry in blood-mimicking fluids
    Joanna Brunker
    Paul Beard
    Scientific Reports, 6
  • [7] Erratum: Acoustic resolution photoacoustic Doppler velocimetry in blood-mimicking fluids
    Joanna Brunker
    Paul Beard
    Scientific Reports, 6
  • [8] RESOLUTION OF ULTRASOUND PULSED DOPPLER FOR BLOOD VELOCITY-MEASUREMENTS
    MORRIS, RL
    HISTAND, MB
    MILLER, CW
    JOURNAL OF BIOMECHANICS, 1973, 6 (06) : 701 - &
  • [9] Acoustic resolution photoacoustic Doppler flowmetry for assessment of patient rectal cancer blood perfusion
    Kou, Sitai
    Leng, Xiandong
    Luo, Hongbo
    Nie, Haolin
    Zhu, Quing
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29
  • [10] CURRENT VELOCITY-MEASUREMENTS USING ACOUSTIC DOPPLER BACKSCATTER - A REVIEW
    WOODWARD, WE
    APPELL, GF
    IEEE JOURNAL OF OCEANIC ENGINEERING, 1986, 11 (01) : 3 - 6