Application of Chemometrics for Spectral Resolving and Determination of Three Analgesics in Water Samples

被引:9
|
作者
Yehia, Ali M. [1 ,2 ]
Elbalkiny, Heba T. [3 ]
Riad, Safa'a M. [1 ,3 ]
Elsaharty, Yasser S. [1 ]
机构
[1] Cairo Univ, Fac Pharm, Analyt Chem Dept, 13 Kasr El Aini St, Cairo 11562, Egypt
[2] Badr Univ Cairo, Sch Pharm & Pharmaceut Ind, Chem Dept, Cairo Suez St, Cairo 11829, Egypt
[3] October Univ Modern Sci & Arts, Fac Pharm, Analyt Chem Dept, 6th October City 11787, Egypt
关键词
ARTIFICIAL NEURAL-NETWORK; SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; MULTIVARIATE CALIBRATION; HUMAN PHARMACEUTICALS; QUATERNARY MIXTURE; MASS-SPECTROMETRY; GUAIFENESIN; RESOLUTION;
D O I
10.5740/jaoacint.19-0140
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Chemometrics is a discipline that allows the spectral resolution of drugs in a complicated matrix (e.g., environmental water samples) as an alternative to chromatographic methods. Objective: Three analgesics were traced in wastewater samples with simple and cost-effective multivariate approaches using spectrophotometric data. Methods and Results: Four chemometric approaches were applied for the simultaneous determination of diclofenac, paracetamol, and ibuprofen. Partial least squares (PLS), principal component regression (PCR), artificial neural networks (ANN), and multivariate curve resolution (MCR)-alternating least squares (ALS) were selected. The presented methods were compared and validated for their qualitative and quantitative analyses. Moreover, statistical comparison between the results obtained by the proposed methods and the official methods showed no significant differences. Conclusions: The proposed multivariate calibrations were accurate and specific for quantitative analysis of the studied components. MCR-ALS is the only method that has the capacity for both the quantitative and qualitative analysis of the studied drugs. Highlights: Four chemometric approaches were used for analysis of severally overlapped ternary mixture of three analgesics. The analytical performance of PCR, PLS, MCR-ALS, and ANN was compared and validated in terms of root mean square error of calibration (RMSEC), SE of prediction, and recoveries. ANN gave the highest predicted concentrations with the lowest RMSEC and root mean square error of prediction. MCR-ALS has the capacity for both qualitative and quantitative measurement. The methods have been effectively applied for real samples and compared to official methods.
引用
收藏
页码:257 / 264
页数:8
相关论文
共 50 条