Dual illumination OCT at 1050nm and 840nm for whole eye segment imaging

被引:0
|
作者
Fan, Shanhui [1 ]
Qin, Lin [1 ]
Dai, Cuixia [1 ]
Zhou, Chuanqing [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai 200240, Peoples R China
关键词
optical coherence tomography; dual illumination; whole eye segment imaging; accommodation; OPTICAL COHERENCE TOMOGRAPHY; SPECTRAL-DOMAIN OCT; ANTERIOR SEGMENT; SWEPT SOURCE; AXIAL BIOMETRY; ACCOMMODATION;
D O I
10.1117/12.2073620
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We presented an improved dual channel dual focus spectral domain optical coherence tomography (SD-OCT) with two illuminations at 840 nm and 1050 nm for whole eye segment imaging and biometry in vivo. The two light beams were coupled and optically optimized to scan the anterior and posterior segment of the eye simultaneously. This configuration with dichroic mirrors integrated in the sample arm enables us to acquire images from the anterior segment and retina effectively with minimum loss of sample signal. In addition, the full resolved complex (FRC) method was applied to double the imaging depth for the whole anterior segment imaging by eliminating the mirror image. The axial resolution for 1050 nm and 840 nm OCT was 14 mu m and 8 mu m in air, respectively. Finally, the system was successfully tested in imaging the unaccommodated and accommodated eyes. The preliminary results demonstrated the significant improvements comparing with our previous dual channel SD-OCT configuration in which the two probing beams had the same central wavelength of 840 nm.
引用
收藏
页数:11
相关论文
共 27 条
  • [1] Ultrahigh speed volumetric ophthalmic OCT imaging at 850nm and 1050nm
    Potsaid, Benjamin
    Liu, Jonathan
    Manjunath, Varsha
    Gorczynska, Iwona
    Srinivasan, Vivek J.
    Jiang, James
    Barry, Scott
    Cable, Alex
    Duker, Jay S.
    Fujimoto, James G.
    OPHTHALMIC TECHNOLOGIES XX, 2010, 7550
  • [2] Ultrahigh Speed Volumetric Ophthalmic OCT Imaging of the Retina at 800nm and 1050nm Wavelengths
    Potsaid, B.
    Liu, J. J.
    Manjunath, V.
    Tsai, T. -H.
    Duker, I. S.
    Huang, D.
    Schuman, J. S.
    Fujimoto, J. G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [3] Analysis of the glaucomatous optic nerve head using 1050nm OCT
    Flynn, Bethany Esther
    Mortlock, Katharine
    Fergusson, James R.
    White, Nick
    Morgan, James E.
    North, Rachel V.
    Albon, Julie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [4] Megahertz FDML Laser with up to 143nm Sweep Range for Ultrahigh Resolution OCT at 1050nm
    Kolb, Jan Philip
    Klein, Thomas
    Eibl, Mattias
    Pfeiffer, Tom
    Wieser, Wolfgang
    Huber, Robert
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XX, 2016, 9697
  • [5] Megahertz OCT for ultrawide-field retinal imaging with a 1050nm Fourier domain mode-locked laser
    Klein, Thomas
    Wieser, Wolfgang
    Eigenwillig, Christoph M.
    Biedermann, Benjamin R.
    Huber, Robert
    OPTICS EXPRESS, 2011, 19 (04): : 3044 - 3062
  • [6] Integrated 840nm High-Power Dual-Polarization SLED Source
    Gloor, S.
    Rios, J.
    Primerov, N.
    Matuschek, N.
    Duelk, M.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXVII, 2023, 12367
  • [7] Doppler-based angiography of retinoblastoma in diagnostic imaging of pediatric patients: clinical trials with a novel 1050nm OCT system
    Nadiarnykh, Oleg
    Davidoiu, Valentina
    Grafe, Maximilian G. O.
    Verbraak, Frank D.
    Bosscha, Machteld
    Moll, Annette
    De Boer, Johannes
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [8] Multifunctional 1050 nm Spectral Domain OCT System at 147 kHz for Posterior Eye Imaging
    Zhang, Anqi
    Zhang, Qinqin
    Huang, Yanping
    Zhong, Zhiwei
    Wang, Ruikang K.
    SOVREMENNYE TEHNOLOGII V MEDICINE, 2015, 7 (01) : 7 - 12
  • [9] A novel 1050nm handheld OCT imaging system for pediatric retinoblastoma patients: technology development and clinical study (Conference Presentation)
    Nadiarnykh, Oleg
    Moll, Annette C.
    de Boer, Johannes F.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XX, 2016, 9697
  • [10] Ultrahigh speed 1050nm swept source / Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second
    Potsaid, Benjamin
    Baumann, Bernhard
    Huang, David
    Barry, Scott
    Cable, Alex E.
    Schuman, Joel S.
    Duker, Jay S.
    Fujimoto, James G.
    OPTICS EXPRESS, 2010, 18 (19): : 20029 - 20048