Outcomes of directional branches using self-expandable or balloon-expandable stent grafts during endovascular repair of thoracoabdominal aortic aneurysms

被引:44
|
作者
Tenorio, Emanuel R. [1 ]
Karkkainen, Jussi M. [1 ]
Mendes, Bernardo C. [1 ]
DeMartino, Randall R. [1 ]
Macedo, Thanila A. [1 ]
Diderrich, Alisa [1 ]
Hofer, Jan [1 ]
Oderich, Gustavo S. [1 ]
机构
[1] Mayo Clin, Div Vasc & Endovasc Surg, Adv Endovasc Aort Res Program, Rochester, MN USA
关键词
Bridging stent; Self-expandable stent graft; Balloon-expandable stent graft; Fenestrated-branched endovascular aneurysm repair; REPORTING STANDARDS; DURABILITY; ENDOGRAFTS;
D O I
10.1016/j.jvs.2019.07.079
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The objective of this study was to evaluate outcomes of directional branches using self-expandable stent grafts (SESGs) or balloon-expandable stent grafts (BESGs) during fenestrated-branched endovascular aneurysm repair of thoracoabdominal aortic aneurysms. Methods: Patients treated by fenestrated-branched endovascular aneurysm repair were enrolled in a prospective study from 2014 to 2018. We included in the analysis patients who had target vessels incorporated by directional branches using either SESG (Fluency [Bard, Covington Ga] or Gore Viabahn [W. L. Gore & Associates, Flagstaff, Ariz]) or BESG (Gore VBX). Target artery instability (TAI) was defined by a composite of any stent stenosis, separation, or type IC or type IIIC endoleak requiring reintervention and stent occlusion, aneurysm rupture, or death due to target artery complication. End points included technical success, target artery patency, freedom from TAI, freedom from type IC or type IIIC endoleak, and freedom from target artery reintervention. Results: There were 126 patients (61% male; mean age, 73 +/- 8 years) included in the study. A total of 335 renal-mesenteric arteries were targeted by directional branches using SESGs in 62 patients and 176 arteries or BESGs in 54 patients and 159 arteries. Patients in both groups had similar thoracoabdominal aortic aneurysm classification and aneurysm and target artery diameter, but SESG patients had significantly (P < .05) shorter stent length (-7 mm) and larger stent diameter (+1 mm) and more often had adjunctive bare-metal stents (72% vs 15%). Technical success was achieved in 99% of patients, with one 30-day death (0.7%). Mean follow-up was significantly longer among patients treated by SESGs compared with BESGs (23 +/- 12 months vs 8 +/- 8months; P < .0001). TAI occurred in 27 directional branches (8%), including 11 type IC endoleaks (2 SESGs, 9 BESGs), 10 stenoses (3 SESGs, 7 BESGs), 4 occlusions (3 SESGs, 1 BESGs), 4 type IIIC endoleaks (2 SESGs, 2 BESGs), and 1 stent separation (SESG), resulting in 20 target artery reinterventions in 16 patients (5 SESGs and 11 BESGs). At 1 year, SESGs had higher primary patency (97% +/- 2% vs 96% +/- 2%; P = .004), freedom from TAI (96% +/- 2% vs 88% +/- 3%; P < .0001), freedom from type IC or type IIIC endoleaks (98% +/- 1% vs 92% +/- 3%; P = .0004), and freedom from target artery reinterventions (98% +/- 1% vs 88% +/- 4%; P < .0001) compared with BESGs. There was no difference in secondary patency for SESGs and BESGs (98% +/- 1% vs 99% +/- 1%; P = .75). Factors associated with TAI were large stent diameter (odds ratio, 0.6; P < .0001) and use of VBX stent graft (odds ratio, 6.5; P < .0001). Conclusions: Directional branches were associated with high technical success and low rates of stent occlusion, independent of stent type. However, primary patency, freedom from TAI, and freedom from type IC or type IIIC endoleaks was lower for BESGs compared with SESGs.
引用
收藏
页码:1489 / +
页数:20
相关论文
共 50 条
  • [1] Outcomes of Directional Branches Using Self-Expandable Versus Balloon-Expandable Stent Grafts During Endovascular Repair of Thoracoabdominal Aortic Aneurysms
    Tenorio, Emanuel R.
    Karkkainen, Jussi M.
    Mendes, Bernardo C.
    DeMartino, Randall R.
    Wigham, Jean
    Diderrich, Alisa
    Hofer, Jan
    Oderich, Gustavo S.
    [J]. JOURNAL OF VASCULAR SURGERY, 2019, 69 (03) : E26 - E26
  • [2] Outcomes of Balloon-expandable Versus Self-expandable Stent Grafts for Endovascular Repair of Iliac Aneurysms Using Iliac Branch Endoprosthesis
    Lima, Guilherme B. Barbosa
    Tenorio, Emanuel R.
    Marcondes, Giulianna B.
    Khasawneh, Mohammad A.
    Mendes, Bernardo C.
    De Martino, Randall
    Shuja, Fahad
    Colglazier, Jill
    Oderich, Gustavo S.
    [J]. JOURNAL OF VASCULAR SURGERY, 2021, 74 (03) : E224 - E225
  • [3] Outcomes of balloon-expandable versus self-expandable stent graft for endovascular repair of iliac aneurysms using iliac branch endoprosthesis
    Lima, Guilherme B.
    Tenorio, Emanuel R.
    Marcondes, Giulianna B.
    Khasawneh, Mohammad A.
    Mendes, Bernardo C.
    DeMartino, Randall R.
    Shuja, Fahad
    Colglazier, Jill J.
    Kalra, Manju
    Oderich, Gustavo S.
    [J]. JOURNAL OF VASCULAR SURGERY, 2022, 75 (05) : 1616 - +
  • [4] Performance of Viabahn balloon-expandable stent compared with self-expandable covered stents for branched endovascular aortic repair
    Motta, Fernando
    Parodi, F. Ezequiel
    Knowles, Martyn
    Crowner, Jason R.
    Pascarella, Luigi
    McGinigle, Katharine L.
    Marston, William A.
    Kibbe, Melina R.
    Ohana, Elad
    Farber, Mark A.
    [J]. JOURNAL OF VASCULAR SURGERY, 2021, 73 (02) : 410 - +
  • [5] Thoracic aortic aneurysms:: Treatment with endovascular self-expandable stent grafts
    Grabenwöger, M
    Hutschala, D
    Ehrlich, MP
    Cartes-Zumelzu, F
    Thurnher, S
    Lammer, J
    Wolner, E
    Havel, M
    [J]. ANNALS OF THORACIC SURGERY, 2000, 69 (02): : 441 - 445
  • [6] Treatment of thoracoabdominal aneurysm with self-expandable aortic stent grafts
    Palma, JH
    Miranda, F
    Gasques, AR
    Alves, CMR
    de Souza, JAM
    Buffolo, E
    [J]. ANNALS OF THORACIC SURGERY, 2002, 74 (05): : 1685 - 1687
  • [7] Effect of branch length and tortuosity on the outcomes of branched endovascular repair of thoracoabdominal aneurysms using self-expandable bridging stent graft
    Piazza, Michele
    Squizzato, Francesco
    Xodo, Andrea
    Gubert, Alberto
    Grego, Franco
    Antonello, Michele
    [J]. JOURNAL OF VASCULAR SURGERY, 2021, 74 (02) : 363 - +
  • [8] Chimney Endovascular Aneurysm Repair Using Endurant Stent-Grafts With Bare Balloon-Expandable Stents for Patients With Juxtarenal Aortic Aneurysms
    Morikage, Noriyasu
    Mizoguchi, Takahiro
    Takeuchi, Yuriko
    Nagase, Takashi
    Samura, Makoto
    Ueda, Koshiro
    Suehiro, Kotaro
    Hamano, Kimikazu
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2019, 26 (03) : 350 - 358
  • [9] BALLOON-EXPANDABLE VERSUS SELF-EXPANDABLE TRANSCATHETER AORTIC VALVE REPLACEMENT
    Okumura, L.
    Sanchez, L.
    Alves, M.
    Candolfi, P.
    [J]. VALUE IN HEALTH, 2021, 24 : S68 - S68
  • [10] Aortic Angulation Does Not Impact Outcomes in Self-Expandable or Balloon-Expandable Transcatheter Aortic Valve Replacement
    Elmously, Adham
    Gray, Katherine D.
    Truong, Quynh A.
    Burshtein, Aaron
    Wong, S. Chiu
    de Biasi, Andreas R.
    Worku, Berhane
    Salemi, Arash
    [J]. CARDIOLOGY, 2018, 140 (02) : 96 - 102