Modeling of the Induced Voltage in a Disconnected Grounded Conductor of a Three-Phase Power Line

被引:0
|
作者
Matsankov, Misho [1 ]
Petrov, Stoyan [1 ]
机构
[1] Tech Univ Sofia, Fac Engn & Pedag, Sofia, Bulgaria
关键词
induced voltage; contact voltage; experimental design;
D O I
10.1109/ICSCGE53744.2021.9654332
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Disconnection of a conductor from a three-phase line causes induction of electrostatic potential in it by the other non-disconnected phase conductors. Such a situation can be dangerous if the conductor is not grounded on both sides, since any contact with it can be related to dangerously high values of the contact voltages. The permissible contact voltage is considered to be the highest value of the voltage that can be applied indefinitely under certain conditions.This creates the necessity to study the resistance of the ground. The paper presents the methodology and the obtained mathematical models for determining the value of the grounding resistance of a disconnected conductor in a three-phase power line, for which the contact voltage is safe, by taking into account the potentials, induced by the non-disconnected phase conductors. Power lines with nominal voltages of 20kV and 110 kV have been considered. The mathematical models have been obtained by implementing the experimental design techniques.
引用
收藏
页码:75 / 78
页数:4
相关论文
共 50 条
  • [1] Modeling the effects of distance in single-conductor power cables in a three-phase power system
    Nersessian, G
    Kaiser, MJ
    ELECTRIC POWER SYSTEMS RESEARCH, 1998, 45 (03) : 191 - 199
  • [2] Voltage Regulator Modeling for the Three-Phase Power Flow in Distribution Networks
    Gallego, L. A.
    Padilha-Feltrin, A.
    2008 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: LATIN AMERICA, VOLS 1 AND 2, 2008, : 929 - 934
  • [3] About the role of the park imaginary power on the three-phase line voltage drop
    Ferrero, A
    Leva, S
    Morando, AP
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2000, 10 (05): : 287 - 296
  • [4] A Three-Phase Unbalanced Line Model with Grounded Neutrals through a Resistance
    Kersting, W. H.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 2651 - 2652
  • [5] Reduction of Neutral Conductor Current in a Three-Phase Four-Wire Low-Voltage Distribution Line
    Aizawa, Tadao
    ELECTRICAL ENGINEERING IN JAPAN, 2010, 171 (04) : 19 - 27
  • [6] Contact-Free Three-Phase Line Voltage Stabilizer for a Three-Wire Power Network
    A. I. Nosov
    E. G. Garbuz
    S. A. Vaganov
    Glass and Ceramics, 2005, 62 : 113 - 116
  • [7] Continuation three-phase power flow: A tool for voltage stability analysis of unbalanced three-phase power systems
    Zhang, XP
    Ju, P
    Handschin, E
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (03) : 1320 - 1329
  • [8] Contact-free three-phase line voltage stabilizer for a three-wire power network
    Nosov, AI
    Garbuz, EG
    Vaganov, SA
    GLASS AND CERAMICS, 2005, 62 (3-4) : 113 - 116
  • [9] Modeling and control of a three-phase power supply
    Contreras, José G.
    Barbi, Ivo
    Revista Tecnica de la Facultad de Ingenieria Universidad del Zulia, 2000, 23 (01): : 35 - 43
  • [10] Impact of Voltage Sags on Three-Phase Power Transformers
    Masoum, Ali S.
    Moses, Paul S.
    Abu-Siada, Ahmed
    2010 20TH AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC 2010): POWER QUALITY FOR THE 21ST CENTURY, 2010,