Fiducial point placement and the accuracy of point-based, rigid body registration

被引:306
|
作者
West, JB
Fitzpatrick, JM
Toms, SA
Maurer, CR
Maciunas, RJ
机构
[1] Vanderbilt Univ, Dept Elect Engn & Comp Sci, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Med Ctr, Dept Neurol Surg, Nashville, TN 37235 USA
[3] Univ Rochester, Dept Neurol Surg, Rochester, NY USA
关键词
fiducial markers; point-based registration; target registration error;
D O I
10.1097/00006123-200104000-00023
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To demonstrate that the shape of the configuration of fiducial points is an important factor governing target registration error (TRE) in point-based, rigid registration. METHODS: We consider two clinical situations: cranial neurosurgery and pedicle screw placement. For cranial neurosurgery, we apply theoretical results concerning TRE prediction, which we have previously derived and validated, to three hypothetical fiducial marker configurations. We illustrate the profile of expected TRE for each configuration. For pedicle screw placement, we apply the same theory to a common anatomic landmark configuration (tips of spinous and transverse processes) used for pedicle screw placement, and we estimate the error rate expected in placement of the screw. RESULTS: in the cranial neurosurgery example, we demonstrate that relatively small values of TRE may be achieved by using widely spread fiducial markers and/or placing the centroid of the markers near the target. We also demonstrate that near-collinear marker configurations far from the target may result in large TRE values. In the pedicle screw placement example, we demonstrate that the screw must be approximately 4 mm narrower than the pedicle in which it is implanted to minimize the chance of pedicle violation during placement. CONCLUSION: The placement of fiducial points is an important factor in minimizing the error rate for point-based, rigid registration. By using as many points as possible, avoiding near-collinear configurations, and ensuring that the centroid of the fiducial points is as near as possible to the target, TREs can be minimized.
引用
收藏
页码:810 / 816
页数:7
相关论文
共 50 条
  • [1] Fiducial point placement and the accuracy of point-based, rigid body registration - Comment
    Roberts, DW
    [J]. NEUROSURGERY, 2001, 48 (04) : 817 - 817
  • [2] Distribution of Fiducial Registration Error in Rigid-Body Point-Based Registration
    Moghari, Mehdi Hedjazi
    Abolmaesumi, Purang
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (11) : 1791 - 1801
  • [3] Selection of fiducial locations and performance metrics for point-based rigid-body registration
    Franaszek, Marek
    Cheok, Geraldine S.
    [J]. PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2017, 47 : 362 - 374
  • [4] Understanding the Effect of Bias in Fiducial Localization Error on Point-Based Rigid-Body Registration
    Moghari, Mehdi Hedjazi
    Abolmaesumi, Purang
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (10) : 1730 - 1738
  • [5] Rigid-body point-based registration: The distribution of the target registration error when the fiducial registration errors are given
    Seginer, A.
    [J]. MEDICAL IMAGE ANALYSIS, 2011, 15 (04) : 397 - 413
  • [6] Predicting error in rigid-body point-based registration
    Fitzpatrick, JM
    West, JB
    Maurer, CR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) : 694 - 702
  • [7] Improvement of registration accuracy in accelerated partial breast irradiation using the point-based rigid-body registration algorithm for patients with implanted fiducial markers
    Inoue, Minoru
    Yoshimur, Michio
    Sato, Sayaka
    Nakamura, Mitsuhiro
    Yamada, Masahiro
    Hirata, Kimiko
    Sasaki, Makoto
    Fujimoto, Takahiro
    Ogura, Masakazu
    Hiraoka, Masahiro
    [J]. MEDICAL PHYSICS, 2015, 42 (04) : 1904 - 1910
  • [8] Derivation of expected registration error for point-based rigid-body registration
    Fitzpatrick, JM
    West, JB
    Maurer, CR
    [J]. MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 16 - 27
  • [9] The distribution of target registration error in rigid-body point-based registration
    Fitzpatrick, JM
    West, JB
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (09) : 917 - 927
  • [10] The distribution of target registration error in rigid-body, point-based registration
    West, JB
    Fitzpatrick, JM
    [J]. INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 1999, 1613 : 460 - 465