MRI Reconstruction From 2D Partial k-Space Using POCS Algorithm

被引:0
|
作者
Chen, Jiaming [1 ]
Zhang, Lu [1 ]
Zhu, Yuemin [2 ,3 ]
Luo, Jianhua [1 ]
机构
[1] Shanghai Jiao Tong Univ, Coll Life Sci & Technol, Shanghai 200240, Peoples R China
[2] CNRS, CREATIS, UMR 5515, F-69100 Villeurbanne, France
[3] INSERM Unit, F-69621 Paris, France
关键词
POCS; 2D partial k-space; MRI reconstruction;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the field of magnetic resonance imaging (MRI), reconstruction from partial k-space data is a common strategy. Projection onto convex set (POCS) method has been applied to dealing with one-dimensional (1D) partial k-space. This paper applied POCS method to MR imaging from two-dimensional (2D) partial k-space data. This method is evaluated with experiments using simulate data. Compared with the zero filling imaging (ZFI) method, reconstruction results of POCS method are much better, especially by selecting partial k-space data of an optimal location. The results show that POCS method however failed to restore some missing data that has no symmetrical part in the original k-space data, leading to inevitable reconstruction errors.
引用
下载
收藏
页码:2662 / +
页数:3
相关论文
共 50 条
  • [1] MRI reconstruction from 2D truncated k-space
    Luo, Jianhua
    Zhu, Yuemin
    Li, Wanqing
    Croisille, Pierre
    Magnin, Isabelle E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (05) : 1196 - 1206
  • [2] Partial K-Space MRI Reconstruction Using a Modified Homodyne Approach
    Abche, Antoine
    Yaacoub, Fadi
    Karam, Elie
    SPA 2010: SIGNAL PROCESSING ALGORITHMS, ARCHITECTURES, ARRANGEMENTS, AND APPLICATIONS CONFERENCE PROCEEDINGS, 2010, : 56 - 61
  • [3] Improved partial k-space reconstruction technique for dynamic myocardial perfusion MRI
    Vijayakumar, Sathya
    Huang, Feng
    DiBella, Edward V. R.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1419 - 1421
  • [4] On optimality of parallel MRI reconstruction in k-space
    Samsonov, Alexey A.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (01) : 156 - 164
  • [5] Algebraic K-Space Identification 2D technique for the automatic extraction of complex k-space of 2D structures in presence of uncertainty
    Brion, Thomas
    Li, Xuefeng
    Fossat, Pascal
    Ichchou, Mohamed
    Bareille, Olivier
    Zine, Abdel-Malek
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2025, 233
  • [6] B-Spline Parameterized Joint Optimization of Reconstruction and K-Space Trajectories (BJORK) for Accelerated 2D MRI
    Wang, Guanhua
    Luo, Tianrui
    Nielsen, Jon-Fredrik
    Noll, Douglas C.
    Fessler, Jeffrey A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (09) : 2318 - 2330
  • [7] MR image reconstruction from partial k-space using singularity function representation
    Miao, Peng
    Hiba, Bassem
    Luo, Jianhua
    Sappey-Marinier, Dominique
    Magnin, Isabelle
    Zhu, Yuemin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 239 - 242
  • [8] Note on the Iterative MRI Reconstruction from Nonuniform k-Space Data
    Knopp, Tobias
    Kunis, Stefan
    Potts, Daniel
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2007, 2007
  • [9] An Optimized k-Space Configuration for Parallel MRI Reconstruction
    Pugachevskii, M. A.
    Polyakov, A. G.
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2020, 54 (01): : 33 - 36
  • [10] An Optimized k-Space Configuration for Parallel MRI Reconstruction
    M. A. Pugachevskii
    A. G. Polyakov
    Biomedical Engineering, 2020, 54 : 33 - 36