Performance studies of low GWP refrigerants as environmental alternatives for R134a in low-temperature applications

被引:9
|
作者
Padmavathy, Saji Raveendran [1 ]
Chockalingam, Murugan Paradesi [2 ]
Kamaraj, Nithyanandhan [2 ]
Glivin, Godwin [3 ]
Thangaraj, Venkatesh [1 ]
Moorthy, Bharathiraja [4 ]
机构
[1] Kongu Engn Coll, Dept Mech Engn, Perundurai 638060, Tamil Nadu, India
[2] Kongu Engn Coll, Dept Automobile Engn, Perundurai 638060, Tamil Nadu, India
[3] Natl Inst Technol, Dept Energy & Environm, Tiruchirappalli 620015, Tamil Nadu, India
[4] Bannari Amman Inst Technol, Dept Automobile Engn, Sathyamangalam 638401, Tamil Nadu, India
关键词
Climate change; Low-temperature system; Exergy; Eco-friendly mixtures; MATLAB; HEAT-TRANSFER CHARACTERISTICS; SYSTEM; SUBSTITUTION; HFC134A; ENERGY;
D O I
10.1007/s11356-021-15875-2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Climate change is an important environmental issue that is causing global temperatures to rise. The primary environmental targets are to reduce carbon emissions and mitigate the impacts of climate change. The refrigeration system is a major emitter of greenhouse gases because it uses refrigerants with a high global warming potential. Due to its excellent thermophysical properties, the R134a is the most commonly used refrigerant in refrigeration systems; however, its high GWP will need to be disposed of earlier. To achieve global environmental objectives, conventional refrigerants need to be replaced with environmentally friendly and energy-efficient refrigerants. In the present work, a mathematical simulation has been carried out to check the performance of low-GWP refrigerant mixtures as environmentally friendly alternatives for R134a in a low-temperature system. In this study, a 190-L domestic refrigerator has been considered a low-temperature system. This simulation was performed using the MATLAB software, and the REFPROP database was used to obtain thermophysical properties of the refrigerants. The results showed that the COP of HFO mixtures decreased by 4-20% compared to R134a. The exergy efficiency of the R1234ze/R134a mixture improves by 4 to 16% as compared to the other mixtures and its performance is very similar to the R134a. Due to the environmentally friendly properties and flammability aspects, R1234ze/R134a (90/10) could be a good substitute for R134a in lower temperature applications and to satisfy the Montreal and Kyoto Protocol expectations.
引用
收藏
页码:85945 / 85954
页数:10
相关论文
共 50 条
  • [1] Performance studies of low GWP refrigerants as environmental alternatives for R134a in low-temperature applications
    Saji Raveendran Padmavathy
    Murugan Paradesi Chockalingam
    Nithyanandhan Kamaraj
    Godwin Glivin
    Venkatesh Thangaraj
    Bharathiraja Moorthy
    [J]. Environmental Science and Pollution Research, 2022, 29 : 85945 - 85954
  • [2] Comparative Performance of Low-GWP Refrigerants as Substitutes for R134a in a Vapor Compression Refrigeration System
    Hamza, Ameer
    Khan, Tauseef Aized
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2020, 45 (07) : 5697 - 5712
  • [3] Comparative Performance of Low-GWP Refrigerants as Substitutes for R134a in a Vapor Compression Refrigeration System
    Ameer Hamza
    Tauseef Aized Khan
    [J]. Arabian Journal for Science and Engineering, 2020, 45 : 5697 - 5712
  • [4] Improvement on the energy performance of a refrigeration system adapting a plate-type heat exchanger and low-GWP refrigerants as alternatives to R134a
    Devecioglu, Atilla G.
    Oruc, Vedat
    [J]. ENERGY, 2018, 155 : 105 - 116
  • [5] Investigation of Performance of Low GWP Alternative to R134a in Centrifugal Chiller
    Du, Y.
    [J]. JOURNAL OF ENGINEERING THERMOPHYSICS, 2021, 30 (01) : 103 - 121
  • [6] Investigation of Performance of Low GWP Alternative to R134a in Centrifugal Chiller
    Y. Du
    [J]. Journal of Engineering Thermophysics, 2021, 30 : 103 - 121
  • [7] Low GWP R134a replacements for small refrigeration (plug-in) applications
    Sethi, Ankit
    Becerra, Elizabet Vera
    Motta, Samuel Yana
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 66 : 64 - 72
  • [8] Overview of low GWP mixtures for the replacement of HFC refrigerants: R134a, R404A and R410A
    Heredia-Aricapa, Y.
    Belman-Flores, J. M.
    Mota-Babiloni, A.
    Serrano-Arellano, J.
    Garcia-Pabon, Juan J.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 111 : 113 - 123
  • [9] Performance of low GWP R1234yf/R134a mixture as a replacement for R134a in automotive air conditioning systems
    Meng, Zhaofeng
    Zhang, Hua
    Lei, Mingjing
    Qin, Yanbin
    Qiu, Jinyou
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 116 : 362 - 370
  • [10] Exergy and performance analysis of low GWP and Non-flammable HFO based refrigerant mixtures as alternatives to R134a
    Kumma, Nagarjuna
    Sarath, Sai
    Kruthiventi, S. S. Harish
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 39