Optimization of a heat pipe-radiator assembly coupled to a recuperated closed Brayton cycle for compact space power plants

被引:21
|
作者
Romano, Luis F. R. [1 ]
Ribeiro, Guilherme B. [1 ]
机构
[1] Aeronaut Inst Technol, Sao Jose Dos Campos, Brazil
关键词
Brayton; Heat pipe; Radiator; Space; Optimization; GENERATION;
D O I
10.1016/j.applthermaleng.2021.117355
中图分类号
O414.1 [热力学];
学科分类号
摘要
Compact and efficient energy conversion systems for space applications enable the appearance of new mission opportunities and technological discoveries resulted from space exploration. Besides energy availability, another crucial factor of any energy conversion system for space purposes is its total mass and size. Focusing on a recuperated closed Brayton cycle (CBC), thermodynamic modeling of a CBC is proposed. Moreover, a thermal model is carried out to predict the overall properties of the cold side of the system (i.e., heat pipes and radiator) for different CBC conditions. Both models are coupled and their conjunct solution provides operational data for the design of the heat rejection system, such as the number of heat pipes (HP), total assembly mass, length, and second-law efficiency. Furthermore, by means of this coupling, the heat source temperature and the cold heat exchanger (CHE) inlet temperature are defined, using an optimization procedure where the specific mass (i.e., radiator mass to cycle power ratio) is minimized. Based on this objective variable, the optimized heat source temperature of 1200 K is achieved, while the CHE inlet temperature of 513.2 K is obtained. Such temperature conditions ensure the future design of a space energy conversion system that aligns good efficiency and compactness.
引用
收藏
页数:13
相关论文
共 30 条
  • [1] Parametric evaluation of a heat pipe-radiator assembly for nuclear space power systems
    Romano, Luis F. R.
    Ribeiro, Guilherme B.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2019, 13
  • [2] Cold-side temperature optimization of a recuperated closed Brayton cycle for space power generation
    Romano, Luis F. R.
    Ribeiro, Guilherme B.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2020, 17 (17)
  • [3] HEAT-PIPE RADIATOR FOR SPACE POWER PLANTS
    WERNER, RW
    CARLSON, GA
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1968, ED15 (10) : 808 - &
  • [4] HEAT-PIPE RADIATOR FOR SPACE POWER PLANTS
    WERNER, RW
    CARLSON, GA
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1968, AES4 (05) : 812 - &
  • [5] Optimization of a closed Brayton cycle for space power systems
    Liu, Haiqing
    Chi, Zhongran
    Zang, Shusheng
    APPLIED THERMAL ENGINEERING, 2020, 179
  • [6] Coupled characteristics and performance of heat pipe cooled reactor with closed Brayton cycle
    Li, Jingkang
    Hu, Zunyan
    Jiang, Hongsheng
    Guo, Yuchuan
    Li, Zeguang
    Zhuge, Weilin
    Xu, Liangfei
    Li, Jianqiu
    Ouyang, Minggao
    ENERGY, 2023, 280
  • [7] Thermodynamic optimization of closed-cycle brayton plants for aerospace power system
    Chen, Lingen
    Sun, Fengrui
    Chen, Wenzhen
    Tuijin Jishu/Journal of Propulsion Technology, 1995, 16 (02):
  • [8] Expectations of closed-brayton-cycle heat exchangers in space power systems
    Barrett, Michael J.
    Johnsont, Paul K.
    JOURNAL OF PROPULSION AND POWER, 2008, 24 (03) : 609 - 613
  • [9] Power optimization of an irreversible closed intercooled regenerated brayton cycle coupled to variable-temperature heat reservoirs
    Wang, WH
    Chen, LG
    Sun, FR
    Wu, C
    APPLIED THERMAL ENGINEERING, 2005, 25 (8-9) : 1097 - 1113
  • [10] Optimum heat conductance distribution for power optimization of a regenerated closed Brayton cycle
    Chen, Lingen
    Sun, Fengrui
    Wu, Chih
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2005, 2 (03) : 243 - 258