Quantification of Retrograde Blood Flow in the Descending Aorta Using Transesophageal Echocardiography in Comparison to 4D Flow MRI

被引:5
|
作者
Wehrum, Thomas [1 ]
Kams, Miriam [1 ]
Guenther, Felix [2 ]
Beryl, Primrose [4 ]
Vach, Werner [4 ]
Dragonu, Iulius [1 ,3 ]
Harloff, Andreas [1 ]
机构
[1] Univ Med Ctr Freiburg, Dept Neurol, D-79106 Freiburg, Germany
[2] Univ Med Ctr Freiburg, Dept Cardiol & Angiol, D-79106 Freiburg, Germany
[3] Univ Med Ctr Freiburg, Dept Radiol Med Phys, D-79106 Freiburg, Germany
[4] Univ Freiburg, Inst Med Biometry & Stat, D-79106 Freiburg, Germany
关键词
Aorta; Descending aorta; Retrograde flow; TEE; 4D flow MRI; ISCHEMIC-STROKE; VISUALIZATION; ETIOLOGY; PLAQUES;
D O I
10.1159/000381682
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Retrograde diastolic blood flow in the proximal descending aorta (DAo), which connects plaques >= 4 mm thickness with brain-supplying arteries, has previously been identified as a possible source of brain embolism. Currently, only 4D flow MRI is able to visualize and quantify potential retrograde embolization pathways in the DAo in-vivo. Hence, it was our aim to test if the extent of retrograde flow could be estimated by routine 2D transesophageal echocardiography (TEE). Methods: Forty-eight acute stroke patients were prospectively included and they underwent Doppler examinations of the transition zone between the aortic arch and the DAo using a 20 mm 2D sample volume in longitudinal section at 90-140 degrees Doppler angle during routine TEE. Velocity-time-integrals (VTI) were studied for ante-grade and retrograde velocities and the ratio (VTIratio) was calculated and correlated with the length of retrograde pathlines at that site, which were visualized using 4D flow MRI at 3-Tesla. A receiver operating characteristic (ROC) curve was used to evaluate a threshold value of VTIratio in differentiating large (>= 3 cm) from small (< 3 cm) retrograde flow extent. Results: At the TEE measurement site, the mean VTIratio was 0.53 +/- 0.16 and the mean length of retrograde pathlines reaching back into the aortic arch was 3.1 +/- 1.4 cm. VTIratio was an independent predictor of retrograde pathline length (r = 0.44; p = 0.002). ROC analysis identified a VTIratio threshold value of 0.6012 with a sensitivity of 0.5, a specificity of 0.92, and positive and negative predictive values of 0.84 and 0.68, respectively. Accordingly, 11 (22.91%) patients had a VTIratio cutoff value >= 0.6012 and corresponding retrograde pathline length >= 3 cm in 4D flow MRI. Conclusions: TEE allows predicting the length of retrograde pathlines. Hence, it may offer a cost-effective way to investigate independent predictors of DAo flow reversal in large-scale studies. However, TEE is only of limited value as a screening tool for high retrograde flow in a clinical setting, as only similar to 23% of patients can be spared 4D flow MRI, which remains indispensable for the exact assessment of individual embolization pathways from plaques of the DAo in-vivo. (c) 2015 S. Karger AG, Basel
引用
收藏
页码:287 / 292
页数:6
相关论文
共 50 条
  • [1] Echocardiographic quantification of retrograde flow in the descending aorta in stroke patients in comparison with 4D flow MRI
    Wehrum, T.
    Guenther, F.
    Kams, M.
    Beryl, P.
    Vach, W.
    Dragonu, I.
    Harloff, A.
    CEREBROVASCULAR DISEASES, 2015, 39 : 20 - 20
  • [2] Quantification of aortic stiffness in stroke patients using 4D flow MRI in comparison with transesophageal echocardiography
    Wehrum, Thomas
    Guenther, Felix
    Kams, Miriam
    Wendel, Sarah
    Strecker, Christoph
    Mirzaee, Hanieh
    Harloff, Andreas
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (10): : 1629 - 1636
  • [3] Quantification of aortic stiffness in stroke patients using 4D flow MRI in comparison with transesophageal echocardiography
    Thomas Wehrum
    Felix Günther
    Miriam Kams
    Sarah Wendel
    Christoph Strecker
    Hanieh Mirzaee
    Andreas Harloff
    The International Journal of Cardiovascular Imaging, 2018, 34 : 1629 - 1636
  • [4] Identification of risk factors of increased retrograde blood flow in the descending aorta using transesophageal echocardiography
    Wehrum, T.
    Guenther, F.
    Wendel, S.
    Fuchs, A.
    Wu, K.
    Beryl, P.
    Vach, W.
    Dragonu, I.
    Harloff, A.
    CEREBROVASCULAR DISEASES, 2015, 39 : 56 - 56
  • [5] Determinants of rotational blood flow in the descending aorta: A transesophageal echocardiography study
    Serdar, Yilmazer Mustafa
    Alper, Aydin
    Tayfun, Gurol
    Sunbul, Aysegul
    Tureli, Hande
    Bahadir, Dagdeviren
    CARDIOVASCULAR DRUGS AND THERAPY, 2007, 21 : S60 - S60
  • [6] Intracardiac Flow at 4D CT: Comparison with 4D Flow MRI
    Lantz, Jonas
    Gupta, Vikas
    Henriksson, Lilian
    Karlsson, Matts
    Persson, Anders
    Carlhall, Carl-Johan
    Ebbers, Tino
    RADIOLOGY, 2018, 289 (01) : 51 - 58
  • [7] Measurement of cardiac valve and aortic blood flow velocities in stroke patients: a comparison of 4D flow MRI and echocardiography
    Thomas Wehrum
    Felix Guenther
    Alexander Fuchs
    Florian Schuchardt
    Anja Hennemuth
    Andreas Harloff
    The International Journal of Cardiovascular Imaging, 2018, 34 : 939 - 946
  • [8] Measurement of cardiac valve and aortic blood flow velocities in stroke patients: a comparison of 4D flow MRI and echocardiography
    Wehrum, Thomas
    Guenther, Felix
    Fuchs, Alexander
    Schuchardt, Florian
    Hennemuth, Anja
    Harloff, Andreas
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (06): : 939 - 946
  • [9] Pulsatile Flow in Descending Aorta: Can Coarctation of Aorta be Ruled out by Transesophageal Echocardiography?
    Diwakar, Anitha
    Chalam, Kolli S.
    Hiremath, C. S.
    Dash, P. K.
    ANNALS OF CARDIAC ANAESTHESIA, 2021, 24 (02) : 253 - 255
  • [10] Use of Multi-Velocity Encoding 4D Flow MRI to Improve Quantification of Flow Patterns in the Aorta
    Callaghan, Fraser M.
    Kozor, Rebecca
    Sherrah, Andrew G.
    Vallely, Michael
    Celermajer, David
    Figtree, Gemma A.
    Grieve, Stuart M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (02) : 352 - 363