Comparison of a new bioprosthetic mitral valve to other commercially available devices under controlled conditions in a porcine model

被引:4
|
作者
Wang, Dee Dee [1 ,2 ]
Caranasos, Thomas G. [1 ,3 ]
O'Neill, Brian P. [1 ,2 ]
Stack, Richard S. [1 ,4 ]
O'Neill, William W. [1 ,2 ]
Chitwood, W. Randolph Jr Jr [1 ,5 ]
机构
[1] Cardiovasc Masters Consortium, Durham, NC USA
[2] Henry Ford Hosp, Div Cardiol, Ctr Struct Heart Dis, Detroit, MI 48202 USA
[3] Univ N Carolina, Div Cardiothorac Surg, Dept Surg, Chapel Hill, NC 27515 USA
[4] Duke Univ, Dept Med, Durham, NC USA
[5] East Carolina Univ, Dept Cardiovasc Sci, Greenville, NC 27858 USA
关键词
epic; left ventricular outflow tract; mitral; mitris; mosaic; valve repair; replacement; SWINE MODEL; PERIMOUNT;
D O I
10.1111/jocs.16021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Aim To evaluate three mitral bioprostheses (of comparable measured internal diameters) under controlled, stable, hemodynamic and surgical conditions by bench, echocardiographic, computerized tomography and autopsy comparisons pre- and postvalve implantation. Methods Fifteen similar-sized Yorkshire pigs underwent preprocedural computerized tomography anatomic screening. Of these, 12 had consistent anatomic features and underwent implantation of a mitral bioprosthesis via thoracotomy on cardiopulmonary bypass (CPB). Four valves from each of three manufacturers were implanted in randomized fashion: 27-mm Epic, 27-mm Mosaic, and 25-mm Mitris bioprostheses. After CPB, epicardial echocardiographic studies were performed to assess hemodynamic function and define any paravalvular leaks, followed by postoperative gated contrast computerized tomography. After euthanasia, animals underwent necropsy for anatomic evaluation. Results All 12 animals had successful valve implantation with no study deaths. Postoperative echocardiographic trans-valve gradients varied among bioprosthesis manufacturers. The 25-mm Mitris (5.1 +/- 2.7)/(2.6 +/- 1.3 torr) had the lowest peak/mean gradient and the 27-mm Epic bioprosthesis had the highest (9.2 +/- 3.7)/(4.6 +/- 1.9 torr). Surgical valve opening area (SOA) varied with the 25-mm Mitris having the largest SOA (2.4 +/- 0.15 cm(2)) followed by the 27-mm Mosaic (2.04 +/- 0.23 cm(2)) and the 27-mm Epic (1.8 +/- 0.27 cm(2)) valve. Bench device orthogonal internal diameter measurements did not match manufacturer device size labeling: 25-mm Mitris (23 x 23 mm), 27-mm Mosaic (23 x 22 mm), 27-mm Epic (21 x 21 mm). Conclusions Current advertisement/packaging of commercial surgical mitral valves is not uniform. This study demonstrates marked variations in hemodynamics, valve opening area and anatomic dimensions between similar sized mitral bioprostheses. These data suggest a critical need for standardization and close scientific evaluation of surgical mitral bioprostheses to ensure optimal clinical outcomes.
引用
收藏
页码:4654 / 4662
页数:9
相关论文
共 21 条
  • [1] EARLY AND LATE RISK OF MITRAL-VALVE REPLACEMENT - A 12 YEAR CONCOMITANT COMPARISON OF THE PORCINE BIOPROSTHETIC AND PROSTHETIC DISK MITRAL-VALVES
    COHN, LH
    ALLRED, EN
    COHN, LA
    AUSTIN, JC
    SABIK, J
    DISESA, VJ
    SHEMIN, RJ
    COLLINS, JJ
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1985, 90 (06): : 872 - 881
  • [2] Antimicrobial effects of pulsed electromagnetic fields from commercially available water treatment devices - controlled studies under static and flow conditions
    Piyadasa, Chathuri
    Yeager, Thomas R.
    Gray, Stephen R.
    Stewart, Matthew B.
    Ridgway, Harry F.
    Pelekani, Con
    Orbell, John D.
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2018, 93 (03) : 871 - 877
  • [3] PHARMACOKINETIC AND PHARMACODYNAMIC STUDIES WITH A NEW CONTROLLED-RELEASE FORMULATION OF PROPRANOLOL IN NORMAL VOLUNTEERS - A COMPARISON WITH OTHER COMMERCIALLY AVAILABLE FORMULATIONS
    PERUCCA, E
    GRIMALDI, R
    GATTI, G
    CARAVAGGI, M
    CREMA, F
    LECCHINI, S
    FRIGO, GM
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1984, 18 (01) : 37 - 43
  • [4] Comparison of serum microRNA in healthy horses and horses with moderate to severe mitral valve regurgitation using a commercially available canine cardiac panel
    Calewaert, Amber
    Palarea-Albaladejo, Javier
    Coultous, Robert
    Capewell, Paul
    Hanks, Eve
    Decloedt, Annelies
    van Loon, Gunther
    EQUINE VETERINARY JOURNAL, 2024,
  • [5] DEVELOPMENT OF A PULSATILE SIMULATOR FOR IN-VITRO ANALYSIS OF THE MITRAL VALVE UNDER CONTROLLED MORPHOMETRIC CONDITIONS
    Pavesi, Andrea
    Vismara, Riccardo
    Votta, Emiliano
    Fiore, Gianfranco B.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 535 - 536
  • [6] Comparison of new formulas of stannous fluoride toothpastes with other commercially available fluoridated toothpastes: A systematic review and meta-analysis of randomised controlled trials
    Clark-Perry, Danielle
    Levin, Liran
    INTERNATIONAL DENTAL JOURNAL, 2020, 70 (06) : 418 - 426
  • [7] COMPARISON OF PATTERN-RECOGNITION METHODS FOR COMPUTER-ASSISTED CLASSIFICATION OF SPECTRA OF HEART SOUNDS IN PATIENTS WITH A PORCINE BIOPROSTHETIC VALVE IMPLANTED IN THE MITRAL POSITION
    DURAND, LG
    BLANCHARD, M
    CLOUTIER, G
    SABBAH, HN
    STEIN, PD
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (12) : 1121 - 1129
  • [8] Evaluation of a new, commercially available kit for the PCR-based detection of Borrella and comparison with 8 other protocols.
    Bittner, T
    Kraiczy, P
    Rittmeister, M
    Brade, V
    Boeddinghaus, B
    INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2004, 294 : 141 - 141
  • [9] A NEW LABORATORY MODEL FOR STUDYING THE VOLATILIZATION OF PESTICIDES UNDER CONTROLLED CONDITIONS
    KUBIAK, R
    MAURER, T
    EICHHORN, KW
    SCIENCE OF THE TOTAL ENVIRONMENT, 1993, 132 (2-3) : 115 - 123
  • [10] Biomechanical Comparison of Cadaveric and Commercially Available Synthetic Osteoporotic Bone Analogues in a Locked Plate Fracture Model Under Torsional Loading
    Becker, Edward H.
    Kim, Hyunchul
    Shorofsky, Michael
    Hsieh, Adam H.
    Watson, Jeffrey D.
    O'Toole, Robert V.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (05) : E136 - E141