Adsorption chiller in a combined heating and cooling system: simulation and optimization by neural networks

被引:26
|
作者
Krzywanski, Jaroslaw [1 ]
Sztekler, Karol [2 ]
Bugaj, Marcin [3 ]
Kalawa, Wojciech [2 ]
Grabowska, Karolina [1 ]
Chaja, Patryk Robert [4 ]
Sosnowski, Marcin [1 ]
Nowak, Wojciech [2 ]
Mika, Lukasz [2 ]
Bykuc, Sebastian [4 ]
机构
[1] Jan Dlugosz Univ Czestochowa, Fac Sci & Technol, Ul A Krajowej 13-15, PL-42200 Czestochowa, Poland
[2] AGH Univ Sci & Technol, Fac Energy & Fuels, Ul A Mickiewicza 30, PL-30059 Krakow, Poland
[3] Warsaw Univ Technol, Fac Power & Aeronaut Engn, Ul Nowowiejska 24, PL-00665 Warsaw, Poland
[4] Polish Acad Sci, Inst Fluid Flow Machinery, Dept Distributed Energy, Ul Fiszera 14, PL-80952 Gdansk, Poland
关键词
adsorption heat pumps; polygeneration; cooling capacity; low-grade thermal energy; artificial neural networks; soft computing; PERFORMANCE EVALUATION; TRANSFER COEFFICIENT; FUZZY-LOGIC; GENETIC ALGORITHMS; BED; PREDICTION; MODEL; CFBC; ADSORBENT; CYCLE;
D O I
10.24425/bpasts.2021.137054
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Adsorption cooling and desalination technologies have recently received more attention. Adsorption chillers, using eco-friendly refrigerants, provide promising abilities for low-grade waste heat recovery and utilization, especially renewable and waste heat of the near ambient temperature. However, due to the low coefficient of performance (COP) and cooling capacity (CC) of the chillers, they have not been widely commercialized. Although operating in combined heating and cooling (HC) systems, adsorption chillers allow more efficient conversion and management of low-grade sources of thermal energy, their operation is still not sufficiently recognized, and the improvement of their performance is still a challenging task. The paper introduces an artificial intelligence (AI) approach for the optimization study of a two-bed adsorption chiller operating in an existing combined HC system, driven by low-temperature heat from cogeneration. Artificial neural networks are employed to develop a model that allows estimating the behavior of the chiller. Two crucial energy efficiency and performance indicators of the adsorption chiller, i.e., CC and the COP, are examined during the study for different operating sceneries and a wide range of operating conditions. Thus this work provides useful guidance for the operating conditions of the adsorption chiller integrated into the HC system. For the considered range of input parameters, the highest CC and COP are equal to 12.7 and 0.65 kW, respectively. The developed model, based on the neurocomputing approach, constitutes an easy-to-use and powerful optimization tool for the adsorption chiller operating in the complex HC system.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Experimental Study of an Micro-Combined Cooling, Heating and Power System with an Adsorption Chiller
    Kong, Xiangqiang
    Li, Ying
    Wang, Ruzhu
    Huang, Xinghua
    [J]. 6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1577 - 1585
  • [2] Thermodynamic analysis and optimization of a combined adsorption heating and cooling system
    Yeung, KH
    Sumathy, K
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2003, 27 (15) : 1299 - 1315
  • [3] Research on a combined adsorption heating and cooling system
    Wang, RZ
    Xu, YX
    Wu, JY
    Li, M
    Shou, HB
    [J]. APPLIED THERMAL ENGINEERING, 2002, 22 (06) : 603 - 617
  • [4] Theoretical research of a silica gel-water adsorption chiller in a micro combined cooling, heating and power (CCHP) system
    Li, S.
    Wu, J. Y.
    [J]. APPLIED ENERGY, 2009, 86 (06) : 958 - 967
  • [5] Optimization of a three-bed adsorption chiller by genetic algorithms and neural networks
    Krzywanski, J.
    Grabowska, K.
    Herman, F.
    Pyrka, P.
    Sosnowski, M.
    Prauzner, T.
    Nowak, W.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 153 : 313 - 322
  • [6] COMBINED SOLAR HEATING AND COOLING SYSTEMS: SIMULATION AND DESIGN OPTIMIZATION
    Nurzia, Giovanni
    Franchini, Giuseppe
    Perdichizzi, Antonio
    [J]. ES2008: PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 2, 2009, : 569 - 576
  • [7] Modeling and Optimization of a Combined Cooling, Heating and Power Plant System
    Chandan, Vikas
    Anh-Tuan Do
    Jin, Baoduo
    Jabbari, Faryar
    Brouwer, Jack
    Akrotirianakis, Ioannis
    Chakraborty, Amit
    Alleyne, Andrew
    [J]. 2012 AMERICAN CONTROL CONFERENCE (ACC), 2012, : 3069 - 3074
  • [8] Optimization of combined cooling, heating and power generation by a solar system
    Sanaye, Sepehr
    Sarrafi, Ahmadreza
    [J]. RENEWABLE ENERGY, 2015, 80 : 699 - 712
  • [9] A combined effect absorption chiller for enhanced performance of combined cooling heating and power systems
    Jayasekara, Saliya
    Halgamuge, Saman K.
    [J]. APPLIED ENERGY, 2014, 127 : 239 - 248
  • [10] Modelling of an adsorption chiller for dynamic system simulation
    Schicktanz, M.
    Nunez, T.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (04): : 588 - 595