Performance test of a LSO-APD PET module in a 9.4 Tesla magnet

被引:0
|
作者
Pichler, B [1 ]
Lorenz, E [1 ]
Mirzoyan, R [1 ]
Pimpl, W [1 ]
Roder, F [1 ]
Schwaiger, M [1 ]
Ziegler, SI [1 ]
机构
[1] Tech Univ Munchen, Klinikum Rechts Isar, Nukl Med Klin & Poliklin, D-81675 Munchen, Germany
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
One of the future goals is to install a PET detector in a magnetic field for a combined PET/MRT device. Thus, in this study the influence of a 9.4 Tesla magnetic field on a small scintillation detector with avalanche photodiode (APD) readout was tested. The detector, comprising a 3.7 x 3.7 x 12.0 mm(3) lutetium oxyorthosilicate (LSO) crystal coupled to the 3 mm diametre active surface of an APD was exposed to 511 keV gamma rays from a Na-22 source. The energy resolution at room temperature was 14.4 % (FWHM). Measurements of gain and energy resolution were performed outside and in the center of a homogeneous magnetic field of 9.4 Tesla. Both, the gain and energy resolution were unaffected by the magnetic field being either parallel or orthogonal to the electrical field of the APD. These results prove the potential of using APDs in a combined PET/MRT imaging system.
引用
收藏
页码:1237 / 1239
页数:3
相关论文
共 19 条
  • [1] Effect of temperature on the stability and performance of an LSO-APD PET scanner
    Spanoudalci, Virginia
    McElroy, David P.
    Zell, Karin
    Ziegler, Sibylle I.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 3014 - 3017
  • [2] Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI
    Pichler, BJ
    Judenhofer, MS
    Catana, C
    Walton, JH
    Kneilling, M
    Nutt, RE
    Siegel, SB
    Claussen, CD
    Cherry, SR
    JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (04) : 639 - 647
  • [3] A noninvasive LSO-APD blood radioactivity monitor for PET imaging studies
    Shokouhi, S
    Stoll, SP
    Villanueva, A
    Vaska, P
    Schlyer, DJ
    Woody, CL
    Yu, B
    O'Connor, P
    Pratte, JF
    Radeka, V
    Volkow, N
    Fowler, JS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1457 - 1461
  • [4] Studies with a prototype high resolution PET scanner based on LSO-APD modules
    Klinikum rechts der Isar der, Technischen Universitaet Muenchen, Muenchen, Germany
    IEEE Transactions on Nuclear Science, 1998, 45 (3 pt 2): : 1298 - 1302
  • [5] An analog signal processing ASIC for a small animal LSO-APD PET tomograph
    Spanoudaki, V. Ch.
    McElroy, D. P.
    Ziegler, S. I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 564 (01): : 451 - 462
  • [6] Studies with a prototype high resolution PET scanner based on LSO-APD modules
    Pichler, B
    Boning, G
    Lorenz, E
    Mirzoyan, R
    Pimpl, W
    Schwaiger, M
    Ziegler, SI
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1298 - 1302
  • [7] Studies with a prototype high resolution PET scanner based on LSO-APD modules
    Pichler, B
    Boning, G
    Lorenz, E
    Mirzoyan, R
    Pimpl, W
    Schwaiger, M
    Ziegler, SI
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1649 - 1653
  • [8] A non-invasive LSO-APD blood radioactivity monitor for PET imaging studies
    Shokouhi, S
    Stoll, SP
    Villanueva, A
    Vaska, P
    Schlyer, DJ
    Woody, CL
    Yu, B
    O'Connor, P
    Pratte, JF
    Radeka, V
    Volkow, N
    Fowler, JS
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 921 - 925
  • [9] Long-term stability study of a dual layer LSO-APD small animal PET
    Tapfer, A.
    Spanoudaki, V. C.
    Torres-Espallardo, I.
    Schirmer, J.
    Ziegler, S. I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S193 - S193
  • [10] Comparison of Three Approaches for Timing Optimization of a Dual Layer LSO-APD Small Animal PET Scanner
    Tapfer, A.
    Spanoudaki, V.
    Mann, A.
    Ziegler, S. I.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 533 - 536