Geant4 X-ray fluorescence with updated libraries

被引:3
|
作者
Bakr, Samer [1 ]
Cohen, David D. [2 ]
Siegele, Rainer [2 ]
Archer, Jay W. [1 ]
Incerti, Sebastien [3 ]
Ivanchenko, Vladimir [4 ,5 ]
Mantero, Alfonso [6 ]
Rosenfeld, Anatoly [1 ,7 ]
Guatelli, Susanna [1 ,7 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[2] Nucl Sci & Technol Org, Ctr Accelerator Sci, Menai, NSW 2234, Australia
[3] Univ Bordeaux, CENBG, CNRS, UMR 5797, F-33170 Gradignan, France
[4] Geant4 Associates Int Ltd, Hebden Bridge, W Yorkshire, England
[5] Tomsk State Univ, Tomsk, Russia
[6] SWHARD Srl, Genoa, Italy
[7] Univ Wollongong, Illawarra Hlth & Med Res Inst, Wollongong, NSW, Australia
基金
澳大利亚研究理事会;
关键词
Geant4; PIXE; Ionisation cross sections; X-ray fluorescence; IONIZATION CROSS-SECTIONS; COSTER-KRONIG PROBABILITIES; K-SHELL IONIZATION; POLYNOMIAL-APPROXIMATION; SIMULATION; ENERGIES; YIELDS;
D O I
10.1016/j.nimb.2021.09.009
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present the results concerning the development in Geant4 of a new data driven library, called here the ANSTO HF library. This X-ray fluorescence library is based on an approach of particular interest for PIXE simulation applications; however, it can be used in any Geant4 applications where X-ray fluorescence needs to be described. The X-ray fluorescence transition probabilities were calculated within the Hartree-Fock (HF) approach, which is recognised to better reproduce PIXE experimental values compared with the Hartree-Slater approach, adopted in the current default Geant4 EADL data library. These HF X-ray fluorescence transition probabilities were integrated into a new Geant4 library and will be released within Geant4 in the near future. In this paper, we compare the fluorescence X-ray spectra generated by the ANSTO HF library and by the currently available library (EADL-1991 [1]) within Geant4, for targets irradiated with protons and alpha particles with energies up to 10 MeV, a range of interest for PIXE applications. The comparisons were performed for a large set of sample materials spanning a broad range of target atomic numbers. These two approaches were compared to existing experimental measurements performed at the ANSTO heavy ion microprobe beamline using 2 MeV and 3 MeV proton and 10 MeV He2+ ion beams. This work represents a useful upgrade to the Geant4 atomic de-excitation package.
引用
收藏
页码:11 / 19
页数:9
相关论文
共 50 条
  • [1] X-ray tracing using Geant4
    Buis, E. J.
    Vacanti, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 599 (2-3): : 260 - 263
  • [2] Validation of a Geant4 model of the X-ray fluorescence microprobe at the Australian Synchrotron
    Dimmock, Matthew Richard
    de Jonge, Martin Daly
    Howard, Daryl Lloyd
    James, Simon Alexander
    Kirkham, Robin
    Paganin, David Maurice
    Paterson, David John
    Ruben, Gary
    Ryan, Chris Gregory
    Brown, Jeremy Michael Cooney
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 354 - 365
  • [3] A generic X-ray tracing toolbox in Geant4
    Vacanti, Giuseppe
    Buis, Ernst-Jan
    Collon, Maximilien
    Beijersbergen, Marco
    Kelly, Chris
    [J]. EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE, 2009, 7360
  • [4] GEANT4 X-ray transition radiation package
    Grichine, V. M.
    Sadilov, S. S.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (02): : 299 - 302
  • [5] GEANT4 models for X-ray transition radiation
    Grichine, VM
    Sadilov, SS
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 522 (1-2): : 122 - 125
  • [6] Validation of the Geant4 Monte Carlo package for X-ray fluorescence spectroscopy in triaxial geometry
    Amaro, Pedro
    Santos, Jose Paulo
    Samouco, Ana
    Adao, Ricardo
    Martins, Luis Souto
    Weber, Sebastian
    Tashenov, Stanislav
    Carvalho, Maria Luisa
    Pessanha, Sofia
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 130 : 60 - 66
  • [7] Validation of Geant4 X-Ray Fluorescence Transitions - Validation of Geant4 electromagnetic models against calorimetry measurements in the energy range up to 1 MeV
    Lechner, Anton
    Mantero, Alfonso
    Pia, Maria Grazia
    Sudhakar, Manju
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2144 - +
  • [8] Parameterization models for X-ray transition radiation in the GEANT4 package
    Apostolakis, J
    Giani, S
    Maire, M
    Bagulya, AV
    Grichine, VM
    [J]. COMPUTER PHYSICS COMMUNICATIONS, 2000, 132 (03) : 241 - 250
  • [9] A GEANT4 based simulation for pixelated X-ray hybrid detectors
    Marinho, F.
    Akiba, K.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 772 : 50 - 51
  • [10] X-Ray Coherent Scatter Diffraction Pattern Modeling in GEANT4
    Kapadia, A.
    Samei, E.
    Harrawood, B.
    Sahbaee, P.
    Chawla, A.
    Tan, Z.
    Brady, D.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3642 - 3643