Method Validation for Extraction of DNA from Human Stool Samples for Downstream Microbiome Analysis

被引:16
|
作者
Neuberger-Castillo, Lorie [1 ]
Hamot, Gael [1 ]
Marchese, Monica [1 ]
Sanchez, Ignacio [1 ]
Ammerlaan, Wim [1 ]
Betsou, Fay [1 ]
机构
[1] Integrated BioBank Luxembourg IBBL, 1 Rue Louis Rech, L-3555 Dudelange, Luxembourg
关键词
biobank; microbiome; fit-for-purpose; validation; stool; 16S; DIVERSITY; BLOOD;
D O I
10.1089/bio.2019.0112
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Background: A formal method validation for biospecimen processing in the context of accreditation in laboratories and biobanks is lacking. A previously optimized stool processing protocol was validated for fitness-for-purpose for downstream microbiome analysis. Materials and Methods: DNA extraction from human stool was validated with various collection tubes, stabilizing solutions and storage conditions in terms of fitness-for-purpose for downstream microbiome analysis, robustness, and sample stability. Acceptance criteria were based on accurate identification of a reference material, homogeneity of extracted samples, and sample stability in a 2-year period. Results: The automated DNA extraction using the chemagic (TM) Magnetic Separation Module I (MSM I) extracted 8 out of 8 bacteria in the ZymoBIOMICS (R) Microbial Community Standard. Seven tested stabilizing solutions (OMNIgene (R)center dot GUT, RNAlater (R), AquaStool (TM), RNAssist, PerkinElmer SEB lysis buffer, and DNA Genotek's CP-150) were all compatible with the chemagic MSM I and showed no significant difference in microbiome alpha diversity and no significant difference in the overall microbiome composition compared to the baseline snap-frozen stool sample. None of the stabilizing solutions showed intensive polymerase chain reaction (PCR) inhibition in the SPUD assay. However, when we take into account more stringent criteria which include a higher double-stranded DNA yield, higher DNA purity, and absence of PCR inhibition, we recommend the use of OMNIgene center dot GUT, RNAlater, or AquaStool as alternatives to rapid freezing of samples. The highest sample homogeneity was achieved with RNAlater- and OMNIgene center dot GUT -stabilized samples. Sample stability after a 2-year storage in -80 degrees C was seen with OMNIgene center dot GUT -stabilized samples. Conclusions: We validated a combination of a stool processing method with various collection methods, suitable for downstream microbiome applications. Sample collection, storage conditions and DNA extraction methods can influence the microbiome profile results. Laboratories and biobanks should ensure that these conditions are systematically recorded in the scope of accreditation.
引用
收藏
页码:102 / 116
页数:15
相关论文
共 50 条
  • [1] Rapid bacterial DNA extraction from stool samples
    Duggan, Megan
    Parrish, Torrey
    Williams, Patrick
    FASEB JOURNAL, 2012, 26
  • [2] Extraction of human nuclear DNA from feces samples using the QlAamp DNA stool mini kit
    Vandenberg, N
    van Oorschot, RAH
    JOURNAL OF FORENSIC SCIENCES, 2002, 47 (05) : 993 - 995
  • [3] Validation of a universal DNA extraction method for human and microbiAL DNA analysis
    Alessandrini, Federica
    Brenciani, Andrea
    Fioriti, Simona
    Melchionda, Filomena
    Mingoia, Marina
    Morroni, Gianluca
    Tagliabracci, Adriano
    FORENSIC SCIENCE INTERNATIONAL GENETICS SUPPLEMENT SERIES, 2019, 7 (01) : 256 - 258
  • [4] Microbiome Analysis of Stool Samples from African Americans with Colon Polyps
    Brim, Hassan
    Yooseph, Shibu
    Zoetendal, Erwin G.
    Lee, Edward
    Torralbo, Manolito
    Laiyemo, Adeyinka O.
    Shokrani, Babak
    Nelson, Karen
    Ashktorab, Hassan
    PLOS ONE, 2013, 8 (12):
  • [5] Development of Rapid Extraction Method of Mycobacterium avium Subspecies paratuberculosis DNA from Bovine Stool Samples
    Hansen, Soeren
    Roller, Marco
    Alslim, Lamia M. A.
    Boehlken-Fascher, Susanne
    Fechner, Kim
    Czerny, Claus-Peter
    Wahed, Ahmed Abd El
    DIAGNOSTICS, 2019, 9 (02):
  • [6] Microbial diversity in fecal samples depends on DNA extraction method: EasyMag DNA extraction compared to QIAamp DNA stool mini kit extraction
    Mirsepasi H.
    Persson S.
    Struve C.
    Andersen L.O.B.
    Petersen A.M.
    Krogfelt K.A.
    BMC Research Notes, 7 (1)
  • [7] Choice of DNA extraction method affects stool microbiome recovery and subsequent phenotypic association analyses
    Fernandez-Pato, Asier
    Sinha, Trishla
    Gacesa, Ranko
    Andreu-Sanchez, Sergio
    Gois, Milla F. Brandao
    Gelderloos-Arends, Jody
    Jansen, Dianne B. H.
    Kruk, Marloes
    Jaeger, Martin
    Joosten, Leo A. B.
    Netea, Mihai G.
    Weersma, Rinse K.
    Wijmenga, Cisca
    Harmsen, Hermie J. M.
    Fu, Jingyuan
    Zhernakova, Alexandra
    Kurilshikov, Alexander
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [8] Choice of DNA extraction method affects stool microbiome recovery and subsequent phenotypic association analyses
    Asier Fernández-Pato
    Trishla Sinha
    Ranko Gacesa
    Sergio Andreu-Sánchez
    Milla F. Brandao Gois
    Jody Gelderloos-Arends
    Dianne B. H. Jansen
    Marloes Kruk
    Martin Jaeger
    Leo A. B. Joosten
    Mihai G. Netea
    Rinse K. Weersma
    Cisca Wijmenga
    Hermie J. M. Harmsen
    Jingyuan Fu
    Alexandra Zhernakova
    Alexander Kurilshikov
    Scientific Reports, 14
  • [9] SYSTEMATIC EXTRACTION OF BACTERIAL DNA FOR LUNG MICROBIOME ANALYSIS FROM CYSTIC FIBROSIS SPUTUM SAMPLES
    Hahn, A.
    Perez, G.
    Colberg-Poley, A. M.
    Campos, J.
    Bryant, J.
    Rose, M.
    PEDIATRIC PULMONOLOGY, 2015, 50 : 334 - 334
  • [10] Detection of Human Genomic DNA in Stool Samples From Seven Patients
    Speicher, David
    Hazan, Sabine
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2024, 119 (10S): : S1995 - S1996