Effective Dose to Patients from SPECT and CT During Myocardial Perfusion Imaging

被引:7
|
作者
Brindhaban, Ajit [1 ]
机构
[1] Kuwait Univ, Dept Radiol Sci, POB 31470, Sulibikhat 90805, Kuwait
关键词
myocardial perfusion imaging; SPECT/CT; administered activity; CT dose index; effective dose; ATTENUATION CORRECTION; NATIONAL-SURVEY;
D O I
10.2967/jnmt.119.233874
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Radiation dose to patients from imaging modalities is measured or calculated to assess the risk of the procedure and compare it with the benefits. Periodic review of image acquisition methods and the radiation dose used are an essential part of optimization in medical imaging. The aim of this study was to estimate patient radiation dose from SPECT myocardial perfusion imaging (MPI) using CT images for attenuation correction. Methods: SPECT and CT image acquisition parameters such as administered activity (AA), CT dose index (CTDIvol), and dose-length product for 415 patients who had undergone SPECT MPI using CT attenuation correction were reviewed. Effective dose (ED) for the SPECT part, the CT part and the total ED for the procedure were calculated. AA, CTDIvol, and ED values were compared between the 2 sexes and between body mass indexes (BMIs), imaging scanner models, and imaging centers. Statistical analyses were performed using t tests and 1-way ANOVA at P < 0.05 level of significance. Results: The range of AAs used for MPI was found to be 1,206-1,964 MBq per patient regardless of sex. The resulting mean ED of 8.8 mSv for men was significantly lower (P = 0.002) than the 10.4 mSv for women for SPECT. The range of CTDIvol was 1.12-3.97 mGy, resulting in an mean ED of 0.8 mSv for men, significantly lower (P, 0.001) than the 1.1 mSv for women for CT. The average combined EDs for male and female patients were 9.6 and 11.5 mSv, respectively. A positive correlation was found between AA and patient BMI (r = 0.48; P < 0.001), indicating patient size-related AAs. However, CTDIvol was found to depend only on the scanner model, regardless of BMI. Conclusion: The ED from SPECT/CT MPI studies was around 11 mSv, with 10 mSv being from the SPECT part of the study. The extra risk to the patients from CT imaging for attenuation correction is small compared with the benefit incurred from accurate diagnosis.
引用
收藏
页码:143 / 147
页数:5
相关论文
共 50 条
  • [1] Reducing CT dose in myocardial perfusion SPECT/CT
    O'Shaughnessy, Emma
    Dixon, Kat L.
    NUCLEAR MEDICINE COMMUNICATIONS, 2015, 36 (11) : 1150 - 1154
  • [2] SPECT Versus PET Myocardial Perfusion Imaging in Patients with Equivocal CT
    Vasvi Singh
    Marcelo F. Di Carli
    Current Cardiology Reports, 2020, 22
  • [3] SPECT Versus PET Myocardial Perfusion Imaging in Patients with Equivocal CT
    Singh, Vasvi
    Di Carli, Marcelo F.
    CURRENT CARDIOLOGY REPORTS, 2020, 22 (06)
  • [4] Prone SPECT imaging, an effective remedy for artifacts seen in supine SPECT/CT myocardial perfusion scans
    Nycz, Jozef
    Freeman, Marc
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [5] Low dose hybrid cardiac imaging with myocardial perfusion SPECT and coronary CT angiography
    Husmann, L.
    Valenta, I.
    Veit-Haibach, P.
    Gaemperli, O.
    Tatsugami, F.
    Herzog, B.
    Plass, A.
    Wyss, C. A.
    Von Schulthess, G.
    Kaufmann, P. A.
    EUROPEAN HEART JOURNAL, 2008, 29 : 281 - 281
  • [6] Low-dose CT from myocardial perfusion SPECT/CT allows the detection of anemia in preoperative patients
    Antonio G. Gennari
    Hannes Grünig
    Dominik C. Benz
    Stephan Skawran
    Alexander Maurer
    Ahmad M. A. Abukwaik
    Alexia Rossi
    Catherine Gebhard
    Ronny R. Buechel
    Michael Messerli
    Journal of Nuclear Cardiology, 2022, 29 : 3236 - 3247
  • [7] Low-dose CT from myocardial perfusion SPECT/CT allows the detection of anemia in preoperative patients
    Gennari, Antonio G.
    Grunig, Hannes
    Benz, Dominik C.
    Skawran, Stephan
    Maurer, Alexander
    Abukwaik, Ahmad M. A.
    Rossi, Alexia
    Gebhard, Catherine
    Buechel, Ronny R.
    Messerli, Michael
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (06) : 3236 - 3247
  • [8] Myocardial perfusion SPECT imaging in patients with myocardial bridging
    Enrique Vallejo
    Mario Morales
    Isabel Sánchez
    Gustavo Sánchez
    José Carlos Alburez
    David Bialostozky
    Journal of Nuclear Cardiology, 2005, 12 : 318 - 323
  • [9] Myocardial perfusion SPECT imaging in patients with myocardial bridging
    Vallejo, E
    Morales, M
    Sánchez, I
    Sánchez, G
    Alburez, JC
    Bialostozky, D
    JOURNAL OF NUCLEAR CARDIOLOGY, 2005, 12 (03) : 318 - 323
  • [10] Comparison of IQ-SPECT/CT with conventional SPECT/CT for myocardial perfusion imaging
    Novak, Mackenzie
    Grancorvitz, Abigail
    Johnson, Carlyn
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53