Wideband Modeling, Field Measurement, and Simulation of a 420-kV Variable Shunt Reactor

被引:10
|
作者
Gustavsen, Bjorn [1 ]
Runde, Magne [1 ]
Ohnstad, Trond M. [2 ]
机构
[1] SINTEF Energy Res, NO-7465 Trondheim, Norway
[2] Statnett, NO-0379 Oslo, Norway
关键词
Black-box model; Electromagnetic Transients Program (EMTP); frequency dependency; simulation; transient recovery voltage; transients; variable shunt reactor; ELECTROMAGNETIC TRANSIENTS; POWER TRANSFORMERS; PASSIVITY;
D O I
10.1109/TPWRD.2014.2375556
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A 420-kV gapped-core five-legged variable shunt reactor is modeled in the frequency range 5 Hz-10 MHz based on frequency sweep measurements and curve fitting using rational functions. Comparison with time-domain measurements at reduced voltage shows that the model can accurately predict the transient behavior of the shunt reactor, both for impinging over-voltages and circuit-breaker transient recovery voltages. Among the observations is that mutual coupling between the phases leads to a beat phenomenon in the reactor voltage following disconnection. Representing the shunt reactor by an LC parallel circuit leads to unrealistic results for steep-fronted incoming waves and high-frequency oscillating overvoltages, and for the attenuation of the transient recovery voltage following disconnection.
引用
收藏
页码:1594 / 1601
页数:8
相关论文
共 22 条
  • [1] Transients caused by switching of 420 kV three-phase variable shunt reactor
    Zupan, Alan
    Filipovic-Grcic, Bozidar
    Filipovic-Grcic, Dalibor
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 138 : 50 - 57
  • [2] Fast operating controlled shunt reactor of transformer type, 420 kV, 50 Mvar
    Aleksandrov, G.N.
    Elektrichestvo, 2002, (03): : 64 - 66
  • [3] Simulation and actual measurement based analysis on harmonic characteristic of 750 kV magnetically controlled shunt reactor
    Zhou, Peipeng
    Xiang, Zutao
    Zheng, Bin
    Ban, Liangeng
    Wang, Dongyang
    Yang, Daye
    Wang, Maoqing
    Han, Yanan
    Dianwang Jishu/Power System Technology, 2014, 38 (04): : 1059 - 1063
  • [4] Overvoltage Simulation Analysis and Suppression of Breaking in a 35 kV Shunt Reactor
    Chen, Jing
    Chen, Xiaoyue
    Feng, Siying
    Liu, Xinmeng
    Liu, Qin
    ENERGIES, 2025, 18 (05)
  • [5] Modelling of variable shunt reactor in transmission power system for simulation of switching transients
    Zupan, Alan
    Filipovic-Grcic, Bozidar
    Uglesic, Ivo
    2017 40TH INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2017, : 598 - 602
  • [6] Based on the BEM of Internal Electric Field Simulation of Shunt Dry Reactor
    Mei Xin
    Lu Tiecheng
    Su Ziming
    Guo Ting
    Yue Long
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [7] Overvoltage Simulation and Analysis of Switching-off Shunt Reactor with 12kV Vacuum Circuit Breaker
    Liu, Guote
    Guo, Fang
    Yuan, Kaifeng
    2020 5TH ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2020), 2020, : 1610 - 1614
  • [8] Modeling and Simulation of Continuously Variable Series Reactor for Power System Transient Analysis
    Young, Marcus
    Li, Zhi
    Dimitrovski, Aleksandar
    2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [9] THE EFFECT OF EXPERIMENTAL-MEASUREMENT UNCERTAINTIES ON RATE MODELING AND REACTOR SIMULATION
    JOFFRION, LL
    MCGREGOR, DR
    JOHNSON, MG
    AKGERMAN, A
    CHEMICAL ENGINEERING COMMUNICATIONS, 1989, 76 : 41 - 51
  • [10] Electric-field Simulation of Insulation Type Test of ± 420kV HVDC Flexible Converter Valve
    Liu, Chenyang
    Han, Kun
    Yao, Weizheng
    Hu, Siquan
    Zheng, Xiaoquan
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 2092 - 2095