Intravascular Ultrasound Complements the Diagnostic Capability of Carbon Dioxide Digital Subtraction Angiography for Patients with Allergies to Iodinated Contrast Medium

被引:7
|
作者
Kusuyama, Takanori [1 ]
Iida, Hidetaka
Mitsui, Hideya [2 ]
机构
[1] Tsukazaki Hosp, Dept Cardiol, Aboshi Ku, Himeji, Hyogo 6711227, Japan
[2] Tsukazaki Hosp, Dept Cardiovasc Surg, Himeji, Hyogo 6711227, Japan
关键词
drug allergy; carbon dioxide; peripheral artery disease; intravascular ultrasound; CO2; ANGIOGRAPHY;
D O I
10.1002/ccd.24577
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Carbon dioxide digital subtraction angiography (CO2 DSA) is a useful and safe alternative for patients with renal dysfunction or allergies to iodinated contrast medium. However, CO2 DSA image quality is worse than that of angiography with iodinated contrast medium, primarily because of movement during imaging and stent struts. In angioplasty of arteries of the lower extremities, CO2 DSA cannot be used to sufficiently evaluate target lesions and determine the most efficient intervention. However, in the current case report, we describe a patient with severe allergies to iodinated contrast medium (Stevens-Johnson syndrome), because of which we were unable to use any iodinated contrast medium when conducting angioplasty. Therefore, we used intravascular ultrasound (IVUS), which facilitated the complete observation of the target lesion after stent implantation without requiring iodinated contrast medium. In this case, IVUS was used to complement the diagnostic capabilities of CO2 DSA. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:E82 / E86
页数:5
相关论文
共 22 条
  • [1] Digital subtraction angiography of the abdominal aorta and lower extremities:: Carbon dioxide versus iodinated contrast material
    Oliva, VL
    Denbow, N
    Thérasse, É
    Common, AA
    Harel, C
    Giroux, MF
    Soulez, G
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (06) : 723 - 731
  • [2] USE OF CARBON-DIOXIDE AS A CONTRAST-MEDIUM DURING INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY
    YUSUF, SW
    WHITAKER, SC
    GREGSON, RH
    HINDWOOD, D
    WENHAM, PW
    HOPKINSON, BR
    MAKIN, GS
    BRITISH JOURNAL OF SURGERY, 1994, 81 (04) : 610 - 610
  • [3] Stent implantation for chronic total occlusion in the iliac artery using intravascular ultrasound-guided carbon dioxide angiography without iodinated contrast medium
    Higashimori A.
    Yokoi Y.
    Cardiovascular Intervention and Therapeutics, 2013, 28 (4) : 415 - 418
  • [4] Gadolinium and carbon dioxide as an alternative to contrast medium in digital angiography
    Garcia-Monaco, R
    Bertoni, H
    Briggs, J
    Peralta, O
    Da Silva, J
    21ST INTERNATIONAL CONGRESS OF RADIOLOGY, 2000, : 43 - 49
  • [5] Intravascular Ultrasound Imaging Versus Digital Subtraction Angiography in Patients with Peripheral Vascular Disease
    Pliagas, George
    Saab, Fadi
    Stavroulakis, Konstantinos
    Bisdas, Theodosios
    Finton, Sara
    Heaney, Carmen
    McGoff, Theresa
    Hardy, Kimberly
    Adams, George
    Mustapha, J. A.
    JOURNAL OF INVASIVE CARDIOLOGY, 2020, 32 (03): : 99 - 103
  • [6] Gadolinium-based contrast media compared with iodinated media for digital subtraction angiography in azotaemic patients
    Erley, CM
    Bader, BD
    Berger, ED
    Tuncel, N
    Winkler, S
    Tepe, G
    Risler, T
    Duda, S
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2004, 19 (10) : 2526 - 2531
  • [7] Carbon dioxide (CO2), digital subtraction angiography in trauma patients
    Hawkins, IF
    Caridi, JG
    Wiechmann, BN
    Kerns, SR
    SEMINARS IN INTERVENTIONAL RADIOLOGY, 1997, 14 (02) : 175 - 180
  • [8] A Comparison Between Contrast Assisted Carbon Dioxide Digital Subtraction and Pure Carbon Dioxide Digital Subtraction Angiography in Endovascular Therapy: A Sub-study of the CO2 Angiography Registry (a Prospective Multicenter Trial)
    Fukuoka, Ryota
    Shintani, Yoshiaki
    Fujihara, Masahiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : S29 - S29
  • [9] Are gadolinium-based contrast media really safer than iodinated media for digital subtraction angiography in patients with azotemia?
    Nyman, U
    Elmståhl, B
    Leander, P
    Nilsson, M
    Golman, K
    Almén, T
    RADIOLOGY, 2002, 223 (02) : 311 - 318
  • [10] Lower limb angiography: A prospective study comparing carbon dioxide with iodinated contrast material in 30 patients
    Rolland, Y
    Duvauferrier, R
    Lucas, A
    Gourlay, C
    Morcet, N
    Rambeau, M
    Chaperon, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) : 333 - 337